background image

 

Predator MKII Dump

 

Valve 

 
 

 

 

 

To release captured wastewater lift handle as shown in diagram. 

 

 

 

Water will drain & then depress the handle down to reseal. 

 
 

 
 
 
 
 

Predator MKII Booster

 

inlet 

 

 

Figure

 

5

 shows booster inlet in the closed position 

 

Figure

 

6

 shows inlet opened to connect the vac hose and booster box. 

 

Inlet opens by hand only and will close itself after use. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

A standard wand only requires 350 to 400 psi, any more may result in unnecessary damage to the wand and 
trigger system. 

 

It is recommended that the upholstery tool or stair tool pressure is 150 psi. 

 

To measure the pressure, engage the trigger on your device then adjust accordingly using the pressure control 
knob. 

Содержание Predator MK II

Страница 1: ...1 Polivac Predator MK II Carpet Extractor Machine Operations Manual Trouble Shooting Guide...

Страница 2: ...2 remove from skid now you are ready to clean turn pump switches and vacuum switches on on at a time fill the solution tank connect the power connect solution and vaccuum hoses connect the wand...

Страница 3: ...The heater switch 2 Figure 3 can now be selected and as power is connected the switch will light up RED and this will commence the heater working 7 Water is now being heated up 8 Connect the G Vac ho...

Страница 4: ...back on the brass socket insert the male plug then release To connect the vacuum hose just insert the black hose cuff into plastic pipe FIGURE 2 Pressure Hose Vacuum hose Connect the female solution h...

Страница 5: ...p power switch 4 Vac motor 4 power switch Figure 3 5 Vac motor 5 power switch 6 Machines operating hour timer 7 Thermal pump overload reset switch Predator MKII Pressure Control Figure 4 1 Pressure in...

Страница 6: ...re 6 shows inlet opened to connect the vac hose and booster box Inlet opens by hand only and will close itself after use A standard wand only requires 350 to 400 psi any more may result in unnecessary...

Страница 7: ...motors and causing faults Troubleshooting Fault Remedy 1 No Power to unit Check power cable and power from source Check water in the front tank If full then machine stops completely 2 Heater not work...

Страница 8: ...8 PREDATOR MKII CABINET ASSEMBLY...

Страница 9: ...ion Cabinet Dump Valve Gasket Dump Valve Spout Nut Dome Rubber Seal Continental Trim Vent Grill White Dome Latch Screw Handle Assembly Filter Screen Float Switch Screw Washer Nut Rubber Washer M8 x 30...

Страница 10: ...10 PREDATOR MKII MOTOR PUMP FRAME ASSEMBLY...

Страница 11: ...5mm 35 Washer 36 Tyre 250x4 37 Code PPR018 PPR090 PPR016 PVT029 PPR006 PPR090 PPR009 AAA354 PPR090 PPR005 AAA354 SK006 AAG365 SLB043 PPR053 Description Pump Bolt Castor Wheel W Break Screw Front Frame...

Страница 12: ...12 PREDATOR MKII UNDERCARRIAGE ASSEMBLY...

Страница 13: ...PR080 36 PPR252 37 PPR248 38 PPR060 39 PPR058 40 PPR037 Description VacMotor Mount Spring Rubber Seal Brass Elbow Pressure Gauge S S Self Tap Screw Gauge to Unloader Hose Brass Elbow Brass Elbow Brass...

Страница 14: ...squeegees and like items 6 In the case of proprietary components used by the manufacturer in the product such as engines electrical motors chargers and the like Polivac will pass on any warranty provi...

Отзывы: