               This is an introduction on the use of the Polivac Predator MK II Carpet Extraction unit. 
 

Directions

 

for

 

Use

 

(Please

 

refer

 

to

 

picture

 

as

 

well

 

in

 

next

 

page) 

 
 

 

1.

  Connect 240v extension cable from power source to #1 (Figure 3) power socket on unit.  

 

2.

  Now connect the Male end of solution hose to Female solution outlet on 

the front of the unit (FIGURE 1). 

 

3.

  Connect  the  Female  solution  end  to  the  Male  fitting  on  the  trigger 

of  the  steam cleaning wand (FIGURE 2). 

 

4.

  Ensure dump valve and booster inlet are closed, if these are not in use. 

 

5.

  Fill  machine with  either cold  or  hot water. We  always recommend  pre-spraying  the carpet 

rather than use of Chemical solutions and powders run through the machine, for a number 

of reasons, 1

st

 this gives better results as the chemical has had time to 

work

 on the carpets, 

2

nd 

when  you  extract  with  fresh  water,  you  remove  more  chemical  residue  which  prevents 

re-soiling  and  chemical  build  up.  Finally,  it  extends  the  life  of  your  pump,  the  use  of  high 

alkaline  chemicals  can  cause  premature  failure  not  covered  by  warranty.  NEVER  USE 

FLAMABLE LIQUIDS OR SOLVENTS IN THE STEAMCLEANER 

 

6.

  The  heater  switch  #2  (Figure  3)  can  now  be  selected  and  as  power  is 

connected  the  switch  will  light  up 

RED 

and  this  will  commence  the  heater 

working. 

 

7.

  Water is now being heated up. 

 

8.

  Connect the G Vac hose to the domes nose and the other end to the wand end. (FIGURE 1, 2) 

 

9.

  Change  position  of  the  rocker  switch  #2  (Figure  3)  to 

Pump

  position.  Then  press  pump 

Round

 #3 (Figure 3) switch and vacuum 

Round

 #4&5 (Figure 3) switches accordingly. switch 

on  the  dirt  water  pump 

Round

  switch  at  the  same  time  (if  it  has  an  auto  empty  unit 

installed). 

 

10.

  Dirt  water  will  steadily  suck  into  the  machine  with  vacuum  motors  working.  Once  dirt  water 

reaches  the  optimum  level  in  the  recovery  tank,  whole  machine  will  stop.  This  optimum  level  is 
controlled by a float switch installed in the recovery tank. 

 

11.

  Customer should push all round buttons to off position and should empty the dirt water tank before 

bringing the machine back to operations. 

 
 

12.

  No  need  to  follow  step  #  10  for  auto  carpet  extractor,  as  these  varieties  will  automatically 

empties the recovery tank using auto empty pump installed in the machine. 

 

13.

  MK2  &  MK3  Auto  has  a  monel  screen  installed  in  the  recovery  tank  in  order  to  stop  finer  dirt 

goes in the auto empty pump. It is important to clean this monel screen regularly to turn the auto 
empty function efficiently. 

Содержание Predator MK II

Страница 1: ...1 Polivac Predator MK II Carpet Extractor Machine Operations Manual Trouble Shooting Guide...

Страница 2: ...2 remove from skid now you are ready to clean turn pump switches and vacuum switches on on at a time fill the solution tank connect the power connect solution and vaccuum hoses connect the wand...

Страница 3: ...The heater switch 2 Figure 3 can now be selected and as power is connected the switch will light up RED and this will commence the heater working 7 Water is now being heated up 8 Connect the G Vac ho...

Страница 4: ...back on the brass socket insert the male plug then release To connect the vacuum hose just insert the black hose cuff into plastic pipe FIGURE 2 Pressure Hose Vacuum hose Connect the female solution h...

Страница 5: ...p power switch 4 Vac motor 4 power switch Figure 3 5 Vac motor 5 power switch 6 Machines operating hour timer 7 Thermal pump overload reset switch Predator MKII Pressure Control Figure 4 1 Pressure in...

Страница 6: ...re 6 shows inlet opened to connect the vac hose and booster box Inlet opens by hand only and will close itself after use A standard wand only requires 350 to 400 psi any more may result in unnecessary...

Страница 7: ...motors and causing faults Troubleshooting Fault Remedy 1 No Power to unit Check power cable and power from source Check water in the front tank If full then machine stops completely 2 Heater not work...

Страница 8: ...8 PREDATOR MKII CABINET ASSEMBLY...

Страница 9: ...ion Cabinet Dump Valve Gasket Dump Valve Spout Nut Dome Rubber Seal Continental Trim Vent Grill White Dome Latch Screw Handle Assembly Filter Screen Float Switch Screw Washer Nut Rubber Washer M8 x 30...

Страница 10: ...10 PREDATOR MKII MOTOR PUMP FRAME ASSEMBLY...

Страница 11: ...5mm 35 Washer 36 Tyre 250x4 37 Code PPR018 PPR090 PPR016 PVT029 PPR006 PPR090 PPR009 AAA354 PPR090 PPR005 AAA354 SK006 AAG365 SLB043 PPR053 Description Pump Bolt Castor Wheel W Break Screw Front Frame...

Страница 12: ...12 PREDATOR MKII UNDERCARRIAGE ASSEMBLY...

Страница 13: ...PR080 36 PPR252 37 PPR248 38 PPR060 39 PPR058 40 PPR037 Description VacMotor Mount Spring Rubber Seal Brass Elbow Pressure Gauge S S Self Tap Screw Gauge to Unloader Hose Brass Elbow Brass Elbow Brass...

Страница 14: ...squeegees and like items 6 In the case of proprietary components used by the manufacturer in the product such as engines electrical motors chargers and the like Polivac will pass on any warranty provi...

Отзывы: