1700E AUTO SCRUBBER
Page 2 of 2
TROUBLE SHOOTING
ISSUE
SOLUTION
Machine doesn’t work when "BRUSH" , "SOLUTION" & "VACCUM "
switches are on
1) Check extension lead connection to the inlet socket
in the machine and to the wall socket
2) Recovery Tank may be full. Please empty the tank
"VACCUM" switch is ON but no suction
1) Please check Squuegy assembly has been lowered to
the floor
2) Recovery tank lid may be not closed properly
Machine moves to side ways not straight
height adjustment knob located at the
back of casting to be carefully adjusted
Dirt water still on the floor and hasn’t been sucked properly
Please clean squeegy blades properly for dirt and debris
HOUSEKEEPING
when you are finished the job, ensure the recovery tank is emptied, via the clear hose situated
on the right of the tank. A bucket is best to use for this. Simply unscrew the top valve and the
fluid will pour out. Rinse out the recovery tank with a hose and repeat the process to ensure
the tank is completely clean.
1.
If you have left over solution in the tank then please press the “SOLUTION” switch to
ON position (while power is connected). That should empty the solution left over in tank
2.
Wipe machine over after each use. Care should be taken to clean the underside of the
machine.
3.
Remove the pad or brush from the 1700E. Clean pad or brush, with strong stream of
fresh water. Allow to dry thoroughly before storing.
4.
Remove the squeegee tool and rinse it under running water, ensure that all dirt and
debris are removed from the squeegee blade.
5.
Wipe cord, to clean and check for any damage, each time you roll it up. Wind from
machine end always to avoid twisting.
6.
Equipment should be stored in a secure location with the skirt sitting neatly around the
machine.
7.
All attachments should be removed and stored suitably e.g. on a shelf or in boxes.
8.
Electrical cords should be coiled and tied for protection against damage and for ease of
storing.
POTENTIAL HAZARDS
1. Slip, trip and fall hazards exist when operating this machine.
2. Do not store MM1700 in upright position with brush or pad holder attached.
3. Take care not to run MM1700E over cable.
4. Do not store other equipment or items on top of this scrubber.
5. Do NOT place lead over your shoulder while operating the machine.
STARTING AND USING THE AUTO SCRUBBER CONTINUE…..
8.
Please note machine will automatically come to stop once recovery tank is full. This is
Controlled by a float switch installed in the recovery tank. In order to continue using
the machine, please make sure following
a) Press “ BRUSH” , “SOLUTION , “ VACCUM” switches to off position
b) Then drain the dirt water in the tank sensibly
9. Please note machine tend stop/start frequently when the recovery tank is near full.