6.Placement and installation
7
NAT WS
POLITEC | INSTALLATION MANUAL - VER.2.0
6.1 Placement and installation height
Position the sensor considering the type of surrounding environment and the protection
distance for correct and effective operation.
Position it in such a way that there are no obstacles in its range of action (trees/plants or
objects that can swing or move with the wind or rain if installed outside).
Position the sensor so that sunlight does not hit it directly near the sensors.
SIDE VIEW
VIEW FROM ABOVE
6.2 Anti-crawl
If mounted at a height of less than 3m, the system can also detect the areas underneath the NAT
sensor by suitably adjusting the sensitivity of the two technologies.This is thanks to the inclination
present on the microwave board and PIR which generate an anti-crawl zone.This solution allows you
to limit the detection area even without the use of a bracket.
N.B.:The detection zone can vary according to the installation height and the surrounding
environment
6.3 Pet Immunity
If mounted at a height between 2 and 3m, the sensor manages to identify a pet with a mass not
exceeding 10 kg that walks within the detection area.
10m