21
POLITEC | INSTALLATION MANUAL - VER.3.1
17.1 Walk Test function
17.Appendix B: function details
MANA MW
1.
Select only DIP4 in ON on RX motherboard
2.
Perform the steps to check the position of the lobe in the zone concerned
Complete disturbance:
Continuous buzzer sound
Partial disturbance:
Intermittent buzzer sound
Disturbance absent:
Buzzer sound absent
17.2 Function DIP - MW RX board
1
LEDS
It activates the LED bars
2
FIELD
It displays the signal value on the LED bar
3
OPEN
It turns off automatic gain control
4
WALK
Active Walk Test (buzzer)
5
CAG
It shows automatic gain value
6
SENS
It displays sensitivity value (SENS)
7
5V
It displays 5V power supply
8
9V
It displays 9V power supply
9
13V
It displays 13.8V power supply
10
VOLT
It enables DISPLAY