POLITEC s.r.l. | Manuale MANA IR SMA – Ver. 2.5
32
4 DIP SWITCH RX
TERMINAL
and only TX
All DIP ON: deactivates the alarm relay. This setting is used when the column has only
optical transmitter
1
CH 1
ON
Wire sync: normal operation of receiver
OFF
Optical sync: operation with transmission frequency 1
2
CH 2
ON
Wire sync: not in use
OFF
Optical sync: operation with transmission frequency 2
3
CH 3
ON
Wire sync: not in use
OFF
Optical sync: operation with transmission frequency 3
4
CH 4
ON
Wire sync: not in use
OFF
Optical sync: operation with transmission frequency 4, only 2 receiver active
JUMPER J7
If the disqualification function is activeted, you can increase the sensitivity of the disqualification by
jumper J7
4 DIP SWITCH TX
TEST TX
By setting all DIP to OFF will turn off all transmitters of the column; moving all DIP
ON transmitters are activated at high frequency in order to allow a first visual contact
between transmitter and receiver in case of difficulties at great distances.
1
CH 1
ON
Wire sync: normal operation of transmitter
OFF
Optical sync: operation with transmission frequency 1
2
CH 2
ON
Wire sync: not in use
OFF
Optical sync: operation with transmission frequency 2
3
CH 3
ON
Wire sync: not in use
OFF
Optical sync: operation with transmission frequency 3
4
CH 4
ON
Wire sync: not in use
OFF
Optical sync: operation with transmission frequency 4, only 2 transmitter active