12. Calibration
16
GAPID SENSOR
POLITEC | INSTALLATION MANUAL - VER.2.3
1.
Set the DIP to ON so as to activate the calibration phase.
2.
Select the standard function according to the application.The BLUE LED will indicate the
selected program followed by a confirmation BEEP from the buzzer.
3.
Adjust the sensitivity using the dedicated trimmer by carrying out tests.Whenever the sensor
goes into alarm, the event is signalled with the lighting up of the RED LED and the buzzer.20
seconds must pass between one alarm and the next.It is advisable to adjust the sensitivity of
the sensor to the minimum necessary in order to minimise unwanted detections.
4.
Position the DIP on 1 to exit the calibration phase.
12.1 Calibration with self-learning functions
Use these functions only if you want to acquire particular signals other than the standard ones.
ALL THREE FUNCTIONS CAN BE USED SIMULTANEOUSLY
12.3 Self-learning function for alarm
a)
Place the DIP in ON.
b)
Select function number 7 and wait for confirmation from the BLUE LED and buzzer.
c)
Carry out the disturbance to be recorded.Once this disturbance has started, the RED LED will
light up and go off as soon as this disturbance has ended and a double beep will be given to
confirm acquisition.If the RED LED does not light up, it means that the disturbance is too gentle
to be acquired.
d)
Reselect the standard function.
e)
Place the DIP on 1.
It is advisable to carry out a disturbance for no longer than 10 seconds.