8. Barrier positioning
11
ALES WS
8.1 Precautions before installation
In order to avoid false alarms, it is advisable to place the barriers away from reflecting surfaces, such
as walls or anything that can attenuate the signal.
DO NOT place the barriers if there are plants, bushes or fixed objects in the range that
obstruct the signal and create "grey areas".Leave a corridor of 50cm for distances between
columns greater than 50m
TX
RX
TX
RX
DO NOT place barriers close to roads: vehicle lights directed towards the RX could create
disturbances
DO NOT place barriers near automatic gates: photocell signals can create interference
RX
DO NOT place the barriers close to walls, without spacing the columns with adequate
brackets, as the signal quality may decrease
POLITEC | INSTALLATION MANUAL - VER.2.1