CONTROL AND SECURITY SYSTEMS MANUFACTURER
11
SLIDING GATE ANNUAL MAINTENANCE TABLE
The Sliding Gate Gate is a maintenance free product to a great extent. Following annual checks and
maintenance are recommended to ensure smooth operation , long service life and safety .
Maintenance Item
Check For
Action
Remark
External cabinet
o
Loose Panels /rattling
noise
o
Loose /broken top
cover
o
Glass in contact with
cabinet parts
•
Re -seat panels
•
Seurely re -seat
/replace top cover
•
Re -position
cover/panel for
adequate clearence
with moving parts
Clean with soft damp
cloth as required
Photosensors
o
Dust and contamination
o
Loose connectors
o
Loose/ misaligned
mounts
•
Clean with soft brush
or pressurized dry air
•
Tighten connectors
•
Align, tighten mounts
Glass wings !
o
Bent frame, glass
scraping frame.
o
C hipped or broken
glass with sharp edges
•
Align frame to se t
wing in middle of
panel.
•
Replace glass wing if
damaged.
Safety
requirement!
Pinch rollers (wing
stabilizers)
o
Deformed rubber roller
o
excessive pressure on
one or both rollers
•
Replace pinch roller.
•
Adjust for slight and
equal pressure on
both sides of glass
wing.
Ensure that glass
wing frame is not
bent/ angled.
Sliding Glass
Mechanism
o
Foreign objects,dust or
gummed lubricant in
bottom rail
o
Loose /worn out drive
belt
o
Check sliding bearings
for excessive play/
noise
•
Remove foreign
objects/ Clean
•
Adjust belt
tension/Replace belt
if worn or dama ged
•
Clean and apply light
kubricant as required
Panels must move
smoothly with no
jamming or
excessive noise.
Electronic boards
o
Loose connector plugs
o
Moisture and excessive
dust or foreign objects
•
Tighten plugs
•
Clean
Wiring Harness
o
Damaged, loose, bare
wires
•
Repair/replace
Faulty AC
power wiring
can cause
shock hazard!
Chassis/mechanical
assembly
o
Loose, missing
nuts/bolts
•
Tighten/replace as
required.
Anchoring bolts !
o
Loose floor
anchors
•
Secure/tighten
Unit must be
securely anchored to
floor with no
movement!
AC leakage !
o
AC leakage on chassis ,
o
İmproper grounding
o
Damaged, loose, bare
wired AC power
Repair/replace as
required.
Safety
Requirement!
Содержание SG55