background image

TS200-T Series Tripod Turnstile

User Manual

P a g e

|

1

Copyright©2020 ZKTECO CO., LTD. All rights reserved.

Thank you for choosing our product. Please read the instructions carefully
before operation. Follow these instructions to ensure that the product is
functioning properly. The images shown in this manual are for illustrative
purposes only.

Содержание T Series

Страница 1: ... ZKTECO CO LTD All rights reserved Thank you for choosing our product Please read the instructions carefully before operation Follow these instructions to ensure that the product is functioning properly The images shown in this manual are for illustrative purposes only ...

Страница 2: ...l This manual introduces the operations of TS200 T Series Tripod Turnstile product All figures displayed are for illustration purposes only Figures in this manual may not be exactly consistent with the actual products ...

Страница 3: ...example press OK Window names menu items data table and field names are inside square brackets For example pop up the New User window Multi level menus are separated by forwarding slashes For example File Create Folder Symbols Convention Description This implies about the notice or pays attention to in the manual The general information which helps in performing the operations faster The informati...

Страница 4: ...STALLATION CONDITIONS 7 3 2 CABLING 8 3 3 INSTALLATION 9 4 FUNCTION OVERVIEW 10 4 1 DIP SWITCH FUNCTION 10 4 2 WIRED REMOTE CONTROL OPTION 11 4 3 WIRELESS REMOTE CONTROL OPTION 12 5 EQUIPMENT PRECAUTIONS AND MAINTENANCE 13 5 1 PRECAUTIONS 13 5 2 MAINTENANCE 14 6 TROUBLESHOOTING 15 ATTACHMENT 1 FACTORY SETTINGS 16 ATTACHMENT 2 CONNECTION DIAGRAM OF CONTROL BOARD AND ACCESS CONTROL PANEL 17 ...

Страница 5: ...C 100 120V 200 240V 50Hz 60Hz Arm Length mm 580 Operating Environment Indoor and Outdoor shelter Dimension mm Figure 1 L 1200 W 280 H 980 Operating Temperature 28ºC 60ºC Package Size mm L 1275 W 370 H 1063 Operating Humidity 5 85 Flow Rate Max 30 passages minute Input Control Signal Dry contact Rated Power 18 W Figure 1 ...

Страница 6: ...as shown in Figure 2 1 Figure 2 1 2 2 Power on Test before Installation 1 Please make sure that the power requirements are strictly met to avoid permanent damages to the unit Input voltage AC 100 120V 200 240V Note The tripod turnstile must be connected to the ground earth 2 Power on and wait 30s for the tripod turnstile to finish the self check program 3 Lift the arms manually as shown in Figure ...

Страница 7: ...ggested to install an assistant framework or fence to form a passageway as shown in Figure 3 1 Figure 3 1 Notes 1 When installing the tripod turnstile against the wall please reserve a distance of at least 100 mm in order to open the cover for future adjustment and maintenance 2 The spare space from the end of the arm shall not be greater than 80 mm see Figure 3 1 Lift upwards ...

Страница 8: ...aused by improper operations Figure 3 2 3 2 Cabling There are inlets in the bottom plate for cabling as shown in Figure 3 3 Units of all data is millimeter Power supply and communication wire should go through the inlet Cable protection covers are suggested to use if it is surface mounted Warning The tripod turnstile must be connected to the ground earth there is wiring interface near the power sw...

Страница 9: ... use a horizontal ruler to test the levelness of the mounting plate If the mounting plate is not levelled adjust it with the gaskets provided Note that all the four expansion bolts must be installed properly as shown in Figure 3 4 Figure 3 4 3 Install the turnstile on the mounting plate and tighten the screws Apply screw securing glue before using and putting gaskets on the screws to adjust the di...

Страница 10: ... function Setting Dial 0 to turn off Dial 1 to turn on Dial code function item Unmanned passage time KE 1 KE 2 KE 3 Switch Status Time Period 000 OFF OFF OFF 5S Default 001 OFF OFF ON 10s 010 OFF ON OFF 15s 011 OFF ON ON 20s 100 ON OFF OFF 30s 101 ON OFF ON 40s 110 ON OFF ON 50s 111 ON ON ON 60s Memory Swipe Mode KE 6 Turn on Alarm Mode KE 8 Dial 1 ON to tun on Dial 1 ON to turn on Dial 0 OFF to t...

Страница 11: ...ions Buttons Description Press the button once to open the tripod turnstile on the left and can pass by swiping the card from the left Press the button once to open the tripod turnstile on the right and can pass by swiping the card from the right In emergency mode press the button once to fall the gate lever Then the left and right sides get open and can pass freely without swiping the card Press ...

Страница 12: ...can pass freely without swiping the card Left forbidden Right free First press once and then press once then the left side is forbidden to pass and the right side is free to pass without swiping the card Left free Right forbidden First press once and then press once then the right side is forbidden to pass and the left side is free to pass without swiping the card Left swipe Right forbidden First ...

Страница 13: ... as typhoon is not guaranteed 3 If the temperature is around or below 30º C you are recommended to install a heating plate for the equipment You might need to turn the power on multiple times to let the device automatically heat up through the self check program 4 The service life of this equipment may be shortened if it works outdoors in coastal areas or a region prone to acid rain 2 If the power...

Страница 14: ... repaired once it is damaged It is recommended placing warning signs at conspicuous positions for alerting every passersby to pass carefully and in good order Reasonable maintenance consciousness helps to guarantee long term usage of the tripod turnstile Regular maintenance Cleaning and protection liquid dedicated for stainless steel are recommended to wipe the outer shell of the equipment regular...

Страница 15: ... an access after successful authentication It may be caused by lack of permission or a circuit problem 1 Check whether the user has the permission to pass 2 Use a multimeter to check whether the NO and COM ports of the access control system have a relay signal output 3 Short circuit the ports K1 GND and K2 GND if the turnstile is successfully opened the controller is not normal In this case please...

Страница 16: ... 5 Turnstile Opening Duration 5s 6 Passing Direction Indicator Passing is allowed in both directions 7 Continue Passing Function Disabled 8 Alarm Function Disabled Note The Lock Driving Duration is 5 seconds by default Please set it to 1 second Do not connect an electrically charged objects to any ports of Opening Signal Input otherwise it will damage the control board ...

Страница 17: ...ction Diagram of Control Board and Access Control Panel Warning This is a class A product In a domestic environment this product may cause radio interference so that the user may have to take adequate additional measure ...

Отзывы:

Похожие инструкции для T Series