6
1.3 Specifications
1
Operating mode:
- measurement of photon radiation DER;
- measurement of photon radiation DE;
- indication of settings;
- search (for
РМ1621М, РМ1621МА);
- indication of partial and critical battery
discharge;
- audio and (additionally for
РМ1621М,
РМ1621МА) light and vibro alarm activation
when DE or DER thresholds are exceeded
-
indication of the dosimeter’s number ("blind
dosimeter");
- PC data exchange
2
DER measurement range
- for
РМ1621, РМ1621М
0.1 Sv/h
– 100 mSv/h
- for
РМ1621А, РМ1621МА
0.1 Sv/h
– 1.00 Sv/h
DER indication sub-ranges
0,01
– 9,99 Sv/h;
10,0
– 99,9 Sv/h;
100
– 999 Sv/h;
1,00
– 9,99 mSv/h;
10,0
– 99,9 mSv/h;
100
– 200 mSv/h (РМ1621, РМ1621М);
100
– 999 mSv/h (РМ1621А, РМ1621МА);
1,00
– 2,00 Sv/h (РМ1621А, РМ1621МА).
- DER analogue scale (seven
segments) in a logarithmic gauge
Number of indicated segments (from left to
right) corresponds to the following DER
threshold values on the LCD display:
- one segment
– 0.1 Sv/h;
- two segments
– 1 Sv/h;
- three segments
–- 10 Sv/h;
- four segments
– 100 Sv/h;
- five segments
– 1 mSv/h;
- six segments
– 10 mSv/h;
- seven segments
– 100 mSv/h
3
Maximum permissible intrinsic relative
error of DER measurement
(15 +
К
1
/ +
К
2
) %,
where DER value, mSv/h;
К
1
– coefficient 0.0015 (mSv/h);
К
2
– coefficient 0.01 (mSv/h)
-1
4
DE measurement range
1.0 Sv 9.99 Sv
5
Maximum permissible intrinsic relative
error of DE measurement
15%
6
DE measurement range
0.01 Sv
– 9.99 Sv
Indication sub-ranges:
0.01
– 9.99 Sv;
10.0
– 99.9 Sv;
100
– 999 Sv;
1.00
– 9.99 mSv;
10.0
– 99.9 mSv;
100 999 mSv;
1.0 Sv
– 9.99 Sv
7
Discreteness of DE accumulation time
indication
1 h
Содержание PM1621
Страница 1: ...X RAY AND GAMMA RADIATION PERSONAL DOSIMETERS 1621 Models 1621 1621 1621 1621 OPERATING MANUAL...
Страница 13: ...13 Figure 1 2 General overview of the dosimeter...
Страница 14: ...14 Figure 1 3 Demounting the clip from 1621 and 1621...
Страница 21: ...21 Figure 2 2 Select the 1621 1621 dosimeter operating indication mode...
Страница 22: ...22 Figure 2 3 Setting the DE threshold values...
Страница 23: ...23 Figure 2 4 Setting the DER threshold values...
Страница 24: ...24 Figure 2 5 Indication of audio alarm state on off adjustment of sound volume of 1621 1621 dosimeter...
Страница 35: ...35 ATTACHMENT C reference OVERALL DIMENSIONS EFFECTIVE CENTER OF THE DOSIMETER DETECTOR Figure C 1...