![Polarlite 1497354 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/polarlite/1497354/1497354_operating-instructions-manual_1572581004.webp)
These operating instructions are published by CEI Conrad Electronic International (HK) Limited, 18th Floor, Tower 2,
Nina Tower, No. 8 Yeung Uk Road, Tsuen Wan, New Territories, Hong Kong. All rights including translation reserved.
Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing systems require
the prior written approval by the editor. Reprinting, also in part, is prohibited. The operating instructions reflect the current
technical specifications at time of print.
© Copyright 2017 by CEI Conrad Electronic International (HK) Limited
*1497354_1499892_v2_1217_02_JC_m_4L
Installation
Heed all information contained in the chapter
“Preparing installation”.
a) Fixing the lamp to the surface
•
Use the foot of the product as a template and mark the drill
hole positions through the screw holes onto the installation
surface.
•
Prepare the surface for installation. It should be dry, clean,
flat and free from debris.
•
Use a 7 mm diameter drill bit to prepare holes for the plastic
dowels.
When drilling or tightening screws, make sure
not to damage any cables, wires or pipes located
underneath the surface.
You can use the holes on the base of the post light as a template to mark where to
place the dowels.
• Drill the holes into the installation surface and insert the dowels into the drill holes.
•
Execute the steps from section “b) Electrical connection”.
•
Align the foot of the product with the dowels and mount the product to the installation surface
using the screws provided (Fig. A).
b)
Electrical connection
•
Carefully pull out the terminal block box from the bottom of
the lamp housing.
• Remove the 4 screws from the lid of the box and then
remove the lid (Fig. B).
• Remove the outer insulation of the mains cable to a length of
maximum 16 mm. Then remove the insulation of the 3 cables
over a length of approx. 6 mm (Fig. C).
The wire of the protective ground conductor (yellow-green)
should be at least 6 mm longer in size in order for it to remain
last in the terminal block in case of failure.
• Carefully cut a hole into the rubber sealing of the terminal
block box and guide the mains cable from outside through
the hole. Use an appropriate sealing agent (such as silicone)
to seal up the hole if it is too large.
• Connect the mains cable with the terminal block:
- Brown cable = L
-
Blue cable = N
- Green/yellow cable = PE/ground wire, grounding symbol
The ground wire must be connected to the terminal block under all circumstances.
If the product is serving as a replacement for an existing light and there is no ground
wire, do not install the product. First install the appropriate supply leads.
If no ground wire is connected, there will be voltage applied to the metal product
housing in the event of an error. This poses a risk of fatal electric shock!
Make sure that the cables are not bare for too long as this may cause short-circuiting.
Make sure that all screw connections on both sides of the terminal block are tight.
•
Reinstall the lid of the terminal block box (observe the correct positioning of the sealing) and
secure it with the 4 screws. Over tightening screws may damage the plastic case!
Check that the rubber gasket around the power supply lead forms a good seal. This will help
prevent moisture from entering the cable inlet.
•
Reinsert the terminal block box back into the lamp.
Make sure that the cables are not squeezed, bent or damaged in any other way. Do
not exert any force when installing the product.
•
Turn on power to the circuit and check to see if the product works.
If the LEDs do not light up, turn off power to the circuit immediately (turn off circuit
breaker and/or automatic fuse). Then check the connection to the power circuit. In
case of doubt, contact a professional (i.e. an electrician).
PIR Sensor (Item No. 1499892)
The built in passive infrared sensor (PIR)
(2)
has a 90 degree angle of coverage, and can
detect motion from up to 6 meters away. You can adjust the distance and LED switch off time
to suit your requirements.
You will need a suitably sized slotted screwdriver to make adjustments. Using
excessive force to adjust the dials may cause damage.
a) Sensor Distance (SENS)
You can adjust the distance the PIR will detect movement (max. 6 meters) by adjusting the dial
marked
SENS (3).
Fig. A
Fig. B
Fig. C
2 m
0
2 m
6 m
b)
Sensor Time (TIME)
You can adjust the LED switch-off time (5 seconds - 6 minutes) by adjusting the dial marked
TIME (3)
.
Care and Cleaning
•
Disconnect the product from the mains before each cleaning.
•
Turn off the product and let it cool down sufficiently before cleaning.
•
Never point a water jet, for example such of high-pressure cleaning equipment, at the lamp,
as that could damage the seals!
• Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as
they can cause damage to the housing and malfunctioning.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the
household waste. At the end of its service life, dispose of the product in accordance
with applicable regulatory guidelines.
You thus fulfill your statutory obligations and contribute to the protection of the
environment.
Technical Data
Input voltage
............................................
220 – 240 V/AC, 50 Hz
Power consumption
.................................
11 W (Item: 1497354)
11.5 W (Item: 1499892)
Material
....................................................
Stainless steel+ Opal PC shade
Protection class .......................................I
Protection type
.........................................IP44
Operating temperature
............................-40 °C to +55 °C
Operating humidity (relative)
...................
0 % to 95 %
Storage temperature
................................
-25 °C to +65 °C
Storage humidity (relative)
.......................
0 % to 95 %
Dimensions (Ø x H)
.................................
98 x 780 mm
Weight
.....................................................
1070 g
LED:
Brightness ................................................
900 lumen
Quantity ...................................................
60 pcs
Color temp
...............................................
2700 – 3000 K
PIR Sensor (Item: 1499892):
...................
Angle of coverage ....................................
90°
Switch-off delay .......................................
5 sec – 6 min
Distance ...................................................
2 – 6 m (adjustable)