Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all 

safety messages.

This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or
“WARNING.” These words mean:

Indicates an imminently hazardous situation which, if not 
avoided, will result in death or injury.

Indicates a hazardous situation which, if not avoided, 
could result in death or serious injury.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you 
what can happen if the instructions are not followed.

Important Instructions

•  Do not use this water heater if any part has been under water. Immediately call a qualified service technician.   

  Water heaters subjected to flood conditions or anytime the gas controls, main burner or ignition control have been  

  submerged in water require replacement of the entire water heater.
•  Hydrogen gas can be produced in a hot water system that has not been used for a long period of time (generally  

  two weeks or more). Hydrogen gas is extremely flammable and can ignite when exposed to a spark or flame. To  

  prevent the possibility of injury under these conditions, we recommend the hot water faucet be opened for several  

  minutes at the kitchen sink before using any electrical appliance which is connected to the hot water system. If  

  hydrogen is present, there will probably be an unusual sound such as air escaping through the faucet as water  

  begins to flow. Do not smoke or have any open flame near the faucet at the time it is open.

The California Safe Drinking Water and Toxic Enforcement Act requires the Governor of California to publish a list of 

substances known to the State of California to cause cancer, birth defects, or other reproductive harm, and requires 

businesses to warn of potential exposure to such substances.

Warning:

  This product contains a chemical known to the State of California to cause cancer, birth defects, or other 

reproductive harm. 
This appliance can cause low-level exposure to some of the substances listed in the act.

Water Heater Safety  ............................................................................ 1-2

Installation Instructions  ...................................................................... 3-22

   Unpacking the Water Heater  ............................................................ 3

 

State of Massachusetts Installation Requirements  ........................... 4

 

Location Requirements  ..................................................................... 5

   Condensate Line   ........................................................................... 6-7

   Intergrated Filter Installation   ............................................................ 8

 

Vent Pipe System  ........................................................................ 9-12

 Vent 

Terminations 

 

...................................................................... 10-13

 

Gas Input Rate  ................................................................................ 14

 

Water System Piping  ................................................................. 14-17

 

Gas Supply and Piping   ............................................................. 18-19

 

Electrical Connections/Wiring Diagram  ..................................... 20-21

 

Installation Checklist  ....................................................................... 22

Operating Your Water Heater  .......................................................... 23-25

Polaris® Operating Instructions   ........................................................... 24

Maintenance of Your Water Heater  ................................................. 25-26

Troubleshooting  .................................................................................... 27

Software Operation Sequence  ............................................................. 28

Parts List and Diagram  ......................................................................... 29

Polaris

®

 Models and Dimensions .......................................................... 30

Table of Contents    

 

 

 

   

Page

Содержание PGC 34-100-2NV

Страница 1: ...s telephone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or...

Страница 2: ...r these conditions we recommend the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance which is connected to the hot water system If hydrogen is p...

Страница 3: ...orized service person The manufacturer and seller of this water heater will not be liable for any damages injuries or deaths caused by failure to comply with the installation and operating instruction...

Страница 4: ...tally vented gas fueled heat ing appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS INSPECTION The s...

Страница 5: ...intain proper clearances as specified on the data plate Figure 1 Garage Installation Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance S...

Страница 6: ...tolerance 1 9 cm 0 31 cm tolerance Note The trap should be aligned so that the exhaust pipe is in a vertical position close to the surface of the water heater Figure 2 Minimum Clearance Locations Back...

Страница 7: ...ate line into the metal drain pan VENT PIPE SYSTEM Carbon Monoxide Hazard Follow all instructions to locate and install the vent pipe system Instructions can be found in this manual in state or local...

Страница 8: ...shell housing by turning clockwise approximately 1 2 30 5 cm and pulling off of the internal clamshell housing see figure 4C Using your fingers or a small flat blade screwdriver remove the filter medi...

Страница 9: ...vent pipe All joints in the inlet and outlet piping must be properly cemented Size and cut all piping before cementing 1 Cut the pipe end square and remove all ragged edges and burrs Make sure the in...

Страница 10: ...12 in 30 cm min vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 ft 61 cm from the center line of the terminal E 12 in 30 cm min clearance to unven...

Страница 11: ...Units on Page 12 for correct terminations if installing more than one Polaris gas water heater Alternative Horizontal Termination The combustion air and exhaust terminations may be raised up to 24 inc...

Страница 12: ...ne or anticipated snow levels See figure 9 below Note See Venting Additional Polaris Units below if installing more than one Polaris gas water heater Venting Additional Polaris Units When using two 2...

Страница 13: ...level 24 61cm Max Figure 12 Through the Roof Termination Notes 1 Support Horizontal Pipe Every Four Feet 1 2 m Support Vertical Pipe Every Six ft 1 8 m 4 Increase The 12 Inch 30 5 cm MinimumAbove Gra...

Страница 14: ...supply use 1 NPT to the fitting marked HOT OUTLET 2 Always use a suitable grade of joint compound and be certain that all fittings are tightened properly 3 The installation of unions in both the hot...

Страница 15: ...ill contaminate the potable water supply Closed System Thermal Expansion As water is heated it expands thermal expansion In a closed system the volume of water will increase As the volume of water inc...

Страница 16: ...the water heater should be ver tical past any mixing valve or supply line to the heating system to remove air bubbles from the system Do not connect the water heater to any system or components previo...

Страница 17: ...ine Must not be smaller than the pipe size of the relief valve or have any reducing coupling installed in the discharge line Must not be capped blocked plugged or contain any valve between the relief...

Страница 18: ...9 for gas piping installation 1 Install a readily accessible manual shut off valve in the gas supply line as recommended by the local utility Know the location of this valve and how to turn off the ga...

Страница 19: ...onally listed recognized fuel gas and carbon monoxide CO detectors are recommended in all applications and should be installed using the manufacturer s instructions and local codes rules or regulation...

Страница 20: ...electrical wiring to the water heater 1 Shut off the power at the electrical service box 2 Loosen the screws securing the access panel to the electrical compartment The electrical wiring diagram model...

Страница 21: ...T L1 NEUTRAL GND PSI PSO PRESSURE SWITCH BLACK WHITE WHITE RED LED YELLOW LED GREEN LED BROWN YELLOW RED THERMOSTAT DIAL ORANGE GAS VALVE BROWN BLUE BLUE WHITE IGNITER RED GREEN YELLOW ORANGE RED 24V...

Страница 22: ...1 8 per foot 10 5 mm per meter Away from corners other vents windows etc Alternate Horizontal Correct relationship outlet to inlet 12 Min 30 5 cm above anticipated snow level 2 exhaust outlet air inle...

Страница 23: ...ich signals the beginning of the ignition sequence see figure 21 and Red Ignition control is signaling the gas valve to open Figure 21 Sequence of Operation When the thermostat calls for heat the blow...

Страница 24: ...e thermostat is adjusted to its lowest temperature setting when it is shipped from the factory Water temperature can be regulated by moving the temperature dial to the preferred setting The preferred...

Страница 25: ...eing shut down during freezing temperatures To drain the tank perform the following steps 1 Turn off the gas supply at the Manual Gas Shut off Valve Turn off the electrical supply to the water heater...

Страница 26: ...Remove the gas valve from the unit keeping the rubber gasket with the gas valve 8 Remove the flange from the gas inlet side of the valve by removing the four 4 attachment screws Figure 25 Replacing t...

Страница 27: ...arity Detection SC SL Soft Lockout Control Automatically resets after 60 minutes SL3 Soft Lockout Hard Lockout Control automatically resets after 60 minutes with a maximum of 3 resets followed by hard...

Страница 28: ...28 SOFTWARE OPERATION SEQUENCE IGNITION CONTROL MODULE SOFTWARE OPERATION SEQUENCE...

Страница 29: ...TE TRAP ASSEMBLY 32 COLD WATER TUBE ASSEMBLY 33 TEMPERATURE AND PRESSURE RELIEF VALVE 34 DRAIN VALVE 35 POTENTIOMETER 36 VENTURI GASKET not pictured 37 BLOWER ISOLATION RELAY TOOLS REQUIRED FOR SERVIC...

Страница 30: ...3 4 40 1 2 41 6 3 8 5 1 2 6 5 8 150 PGC 34 150 2NV OR 2PV 34 150 2 OR 3 48 1 2 22 15 3 4 40 1 2 41 6 3 8 5 1 2 6 5 8 150 PGC 50 130 2NV OR 2PV 50 130 2 OR 3 62 3 8 22 15 3 4 54 1 2 55 6 3 8 5 1 2 6 5...

Страница 31: ...31 NOTES...

Страница 32: ...ed To obtain technical warranty or service assistance during or after the installation of this water heater visit our website at http www americanwaterheater com or call toll free 1 800 456 9805 P O B...

Отзывы: