Polaris PG10* 100-199-3NV Скачать руководство пользователя страница 5

5

CONDENSATE LINE

Important:  

Do not run the condensate drain in areas 

that are likely to freeze. Frozen condensate will block the 
drain line and result in property damage or water heater 
malfunction.

Condensate Trap Assembly

A condensate trap/drain stem assembly has been supplied 
with the water heater and is located behind the access door 
inside the base of the water heater.  This assembly must be 
installed between the water heater and the exhaust outlet 
piping to ensure proper operation of the water heater. To 
install, remove the slip-joint nut, stainless steel washer, and 
O-ring from the trap assembly.  Slip the nut, washer and 
O-ring (in that order) over the stainless exhaust tubing and 
slide them back near the base of the heater.  Insert the trap 
assembly over the tubing (see figure 3A or 3B accordingly) 
and firmly hand-tighten (using a wrench will cause the 
O-ring to seal improperly) the nut to form a water-tight 
seal between the O-ring and the stainless exhaust tubing.  
When tightened, the nut to heater base clearance should 
be 3/4” (+/- 1/8”). On 100 gallon models the condensate 
trap assembly should be glued to the exhaust pipe (see 
figure 3C).

Note: 

 The trap should be aligned so that the exhaust pipe 

is in a vertical position close to the surface of the water 
heater.

Figure 2: Minimum Clearance Locations 

Figure 3A: 2” Condensation Trap Installation 

100,000 - 150,000 BTU/Hr Models 

Clearances and Accessibility

Notice:

  Minimum clearances from combustible materi-

als are stated on the data plate located on the front of the 
water heater.

     The water heater is certified for installation on a

       combustible floor. 

Important:

 If installing over carpeting, the carpeting must 

be protected by a metal or wood panel beneath the water 
heater. The protective panel must extend beyond the full 
width and depth of the water heater by at least 3 inches 
(76.2mm) in any direction or if in a alcove or closet instal-
lation, the entire floor must be covered by the panel. The 
panel must be strong enough to carry the weight of the 
heater when full of water.

Figure 2 may be used as a reference guide to locate the 
specific clearance locations. A minimum of 24 inches of 
front clearance and 4 inches on each side should be pro-
vided for inspection and service. 

Figure 3B: 3” Condensation Trap Installation 

175,000 - 199,000(50 gal.) BTU/Hr Models

Figure 3C: 3” Condensation Trap Installation 

100 Gallon Models

Содержание PG10* 100-199-3NV

Страница 1: ...have the following information ready 1 Model number 2 7 Digit product number 3 Serial number 4 Date of installation 5 Place of Purchase Table of Contents 2 Do not store or use gasoline or other flamm...

Страница 2: ...mend the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance which is connected to the hot water system If hydrogen is present there will probably...

Страница 3: ...ples of qualified service technicians include those trained in the plumbing and heating industry local gas utility personnel or an authorized service person The manufacturer and seller of this water h...

Страница 4: ...ce Maintain proper clearances as specified on the data plate Figure 1 Garage Installation Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other applia...

Страница 5: ...sembly should be glued to the exhaust pipe see figure 3C Note The trap should be aligned so that the exhaust pipe is in a vertical position close to the surface of the water heater Figure 2 Minimum Cl...

Страница 6: ...ctions can be found in this manual in state or local codes or the authority having jurisdiction or in the absence of such the National Fuel Gas Code ANSI Z223 1 NFPA 54 Latest Edition Canadian install...

Страница 7: ...ipe 4 Concentric Vent Through the Wall 5 Concentric Vent Through the Roof All pipe fittings pipe cement primers and procedures must conform to American National Standard Institute and American Society...

Страница 8: ...op and side of window or door that may be opened Do not install below a window or door that may be opened C Clearance to permanently closed window D 12 in 30 cm min vertical clearance to ventilated so...

Страница 9: ...the water heater as possible This is to drain any water that may be in the combustion air pipe and prevent it from entering the blower Connect the trap drain line to a suitable drain or downstream of...

Страница 10: ...gure 9A for the proper location of the air inlet with respect to the exhaust outlet termination The vertical exhaust outlet termination is a 2 inch pipe which terminates at least 12 inches above the i...

Страница 11: ...ures 10A 13Abelow for vent terminal specifications Note For replacement installations previously installed American Water Heater Company supplied concentric vent kits are acceptable for use on 100 000...

Страница 12: ...d inward Install a drain tee assembly and trap in the inlet vent as close to the water heater as possible This is to drain any water that may be in the combustion air pipe and prevent it from entering...

Страница 13: ...for the proper location of the air inlet with respect to the exhaust outlet termination The vertical exhaust outlet termination is a 3 inch pipe which terminates at least 12 inches above the inlet ai...

Страница 14: ...for vent terminal specifications Figure 11B Through the Wall Termination Figure 12B Through the Roof Termination Figure 13B Concentric Vent Piping Installation Note For concentric venting terminations...

Страница 15: ...in along the top side of the nipple 34 50 gal models only Connect the hot water supply 50 gal and below use 1 NPT 100 gal use 1 1 2 NPT to the fitting marked HOT OUTLET 2 Always use a suitable grade o...

Страница 16: ...ng which will contaminate the potable water supply Closed System Thermal Expansion When a backflow prevention device or check valve is installed it can create a Closed System Heating water in a closed...

Страница 17: ...empering valve or supply line to the heating system to remove air bubbles from the system Do not connect the water heater to any system or components previously used with non potable water heating app...

Страница 18: ...ter than or equal to the input rating of the water heater The Discharge Line Must not be smaller than the pipe size of the relief valve or have any reducing coupling installed in the discharge line Mu...

Страница 19: ...ence figure 19 for gas piping installation 1 Install a readily accessible manual shut off valve in the gas supply line as recommended by the local utility Know the location of this valve and how to tu...

Страница 20: ...Nationally listed recognized fuel gas and carbon monoxide CO detectors are recommended in all applications and should be installed using the manufacturer s instructions and local codes rules or regula...

Страница 21: ...ervice box 2 Loosen the screws securing the access panel to the electrical compartment The electrical wiring diagram for 34 50 gal models can be found on the inside of the access panel at the base of...

Страница 22: ...ND GND GND FUSED DISCONNECT L1 NEUTRAL GND PSI PSO PRESSURE SWITCH BLACK WHITE WHITE RED LED YELLOW LED GREEN LED BROWN YELLOW RED THERMOSTAT DIAL ORANGE GAS VALVE BROWN BLUE BLUE WHITE IGNITER RED GR...

Страница 23: ...ds the heater at 1 8 per foot Away from corners other vents windows etc Alternate Horizontal Correct relationship outlet to inlet 12 Min above anticipated snow level 2 exhaust outlet air inlet pipe sl...

Страница 24: ...calling for heat which signals the beginning of the ignition sequence see figure 21 and Red Ignition control is signaling the gas valve to open Figure 21 Sequence of Operation When the thermostat call...

Страница 25: ...systems used with this water heater are designed for temperatures higher than 130 F Refer to the manufacturer s instruction manuals supplied with this type of equipment for recommended temperature se...

Страница 26: ...nnect a hose to the drain valve and terminate it to an adequate drain Note The drain hose should be rated for at least 200 F If the drain hose does not have this rating open the cold water inlet valve...

Страница 27: ...umber 6903775 7 Remove the gas valve from the unit keeping the rubber gasket with the gas valve 8 Remove the flange from the gas inlet side of the valve by removing the four 4 attachment screws Figure...

Страница 28: ...y Detection SC SL Soft Lockout Control Automatically resets after 60 minutes SL3 Soft Lockout Hard Lockout Control automatically resets after 60 minutes with a maximum of 3 resets followed by hard loc...

Страница 29: ...OFTWARE OPERATION SEQUENCE IGNITION CONTROL MODULE SOFTWARE OPERATION SEQUENCE For 175 000 BTU Hr models and above the flame establishing period is six seconds For the first 3 seconds the gas valve is...

Страница 30: ...34 DRAIN VALVE 35 POTENTIOMETER 36 VENTURI GASKET not pictured 37 BLOWER ISOLATION RELAY 150 000 BTU Hr TOOLS REQUIRED FOR SERVICING TOOL FUNCTION VOLT OHMMETER MEASURE VOLTAGE RESISTANCE CLAMP ONAMM...

Страница 31: ...34 DRAIN VALVE 35 TEMPERATURE AND PRESSURE RELIEF VALVE TOOLS REQUIRED FOR SERVICING TOOL FUNCTION VOLT OHMMETER MEASURE VOLTAGE RESISTANCE CLAMP ONAMMETER MEASURE CURRENT STOPWATCH CLOCK GAS CONSUMPT...

Страница 32: ...3 48 1 2 22 15 3 4 40 1 2 41 6 3 8 5 1 2 6 5 8 150 PG10 50 130 2NV OR 2PV 50 130 2 OR 3 62 3 8 22 15 3 4 54 1 2 55 6 3 8 5 1 2 6 5 8 176 PG10 34 150 2NV OR 2PV 34 150 2 OR 3 48 1 2 22 15 3 4 40 1 2 4...

Отзывы: