Winterizing

If installed in an area prone to freezing
temperatures, the pump should be winterized 
to prevent freeze damage.

Pull out drain plug and drain all water from
pump.

Disconnect plumbing hose at quick
disconnects on pump inlet and outlet ports.

When reinstalling, recut the hose to eliminate
crimps or bulges, and to ensure a straight edge
before reconnecting the Softube quick connects.

Polaris 
Reinforced
Hose

1-1/2"

 Rigid 

PVC Pipe

Dedicated 
return line to pool

Expansion 
Anchor

Inlet 
Supply 
Line

Complete Installation

Polaris Booster Pump Limited Warranty

This limited warranty is extended to the original consumer purchaser of this Polaris  Booster Pump manufactured by

Polaris Pool Systems, Inc., 2620 Commerce Way, Vista, CA 92081-8438, USA.
Polaris Pool Systems warrants the  Booster Pump it manufactures, including all parts and components thereof, to be free
of defects in material and workmanship. If you have a question regarding your Polaris Booster Pump, please feel free to
call or write us. Be sure to include the serial number of your unit.

The warranty commences on the date of installation of the pump and shall remain in effect for a period of twelve

months, but in no event shall it be in effect for more than twenty-four months from the date of manufacture of the pump as
established by the serial number.

This limited warranty does not apply if the failure is caused or contributed by any of the following: improper handling,

improper storage, abuse, unsuitable application of the unit, lack of reasonable and necessary maintenance, winter freezing
or repairs made or attempted by other than Polaris Pool Systems or one of its authorized service centers. Polaris will
repair or replace, at its option, a unit or part proved to be defective within the warranty period and under the conditions of
the warranty.

Unless local repair is authorized, the consumer must deliver or ship the unit or the warranty parts, freight prepaid to the

nearest Polaris Authorized Service Center or return it freight prepaid (after proper authorization) to the plant of
manufacture. Authorization to return a unit to the plant of manufacture must be obtained from the Polaris Customer
Service Department. For your convenience, please check with your dealer for the local procedure before exercising this
warranty. If further directions or instructions should be required, contact the Customer Service Department at 1-800-VAC-
SWEEP (USA and Canada only). Be sure to insure your shipments against loss or damage in transit.
Polaris is not responsible for the cost of removal of the unit, damages due to removal, any other expenses incurred in
shipping the unit or parts to or from the factory or its authorized service centers, the installation of the repaired or
replacement unit. The consumer must bear these expenses.

This warranty does not cover repair or replacement of a unit except at our factory or a Polaris Authorized Service

Center.

THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE

IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND ALL SUCH
OTHER WARRANTIES ARE DISCLAIMED EXCEPT TO THE EXTENT ANY IMPLIED WARRANTY MAY BE IMPOSED BY
STATE CONSUMER LAW. ANY SUCH IMPLIED WARRANTY IMPOSED BY STATE CONSUMER LAW IS LIMITED IN
DURATION TO ONE (1) YEAR FROM DATE OF PURCHASE.IN NO EVENT SHALL POLARIS POOL SYSTEMS BE
LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE OR KIND OR FOR DAMAGES TO
PERSONS OR PROPERTY, INCLUDING ANY DAMAGE RESULTING FROM THE USE OF THE POLARIS BOOSTER
PUMP.

Some states do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or

consequential damages, so the above limitations may not apply to you.

This limited warranty is valid only in the United States of America and Canada, and it does not apply to Polaris  Booster

Pumps sold or installed in any other country.

Содержание PB4-60Q

Страница 1: ...me clock is recommended to control the On Off functions of the booster pump A manual switch can also be used If a time clock is used set it to turn the pump on half an hour after the pool filtration pump is turned on and turn the pump off at least half an hour before the filtration pump shuts off Periodically check the time clock settings to make sure they are properly synchronized Plumbing The Po...

Страница 2: ...hread sealant 3 Measure and cut reinforced hose ensuring cut is clean with no more than a 30º off straight edge Avoid unnecessary loops or bends in the hose 4 Push the hose onto the quick connect until it is flush against the hose barb base 5 Holding the hose in place pull and twist the sleeve on the quick connect over the hose as far as possible Snap the clip into place Checking Water Flow After ...

Страница 3: ...the consumer must deliver or ship the unit or the warranty parts freight prepaid to the nearest Polaris Authorized Service Center or return it freight prepaid after proper authorization to the plant of manufacture Authorization to return a unit to the plant of manufacture must be obtained from the Polaris Customer Service Department For your convenience please check with your dealer for the local ...

Страница 4: ...Quick Connect Retainer 4 R OTAT I O N Inlet 13 1 3 6 2 8 9 10 12 11 9 14 4 7 Outlet 16 17 18 15 No Part Description Qty Polaris Booster Pump Part PB4 60 No Part Description Qty 1 P5 Volute Includes Drain Plug 1 2 P15 Impeller 1 3 P55 Seal Stainless Steel Cup Spring 1 4 P95 O Ring Bracket 1 5 P10 Bracket 1 6 P35 Bolt Stainless Bracket to Motor 2 7 P40 O Ring for Shaft 1 8 P61 Motor 3 4 HP Threaded ...

Отзывы: