WARRANTY  

You may obtain additional copies of this manual from our web 
site at www.polarisgate.com, or contact Polaris Gate Operators 
at: 8617 Paseo Alameda NE Albuquerque NM 87113, 
 877-313-8902.  

 
Two Year Limited Warranty  

Limited Warranty Coverage  

If your Polaris Gate Operator (sometimes also referred to as 
the “Product”) does not work properly because of a defect in 
materials or workmanship, Polaris Gate Operators will, for the 
length of the period indicated below, which starts with the date 
of the original purchase by the first non-consumer purchaser 
(the “Limited Warranty period”), at its option either (a) repair 
your Product with new or refurbished parts, or (b) replace it 
with a new or a refurbished Product. The decision to repair or 
replace will be made by Polaris Gate Operators.  

       Parts Labor                  Labor 
       Two (2) Years               Two (2) Years  

During the “Labor” Limited Warranty period there will be no 
charge for labor. (Note: labor applies only to the repair of the 
Product at an Authorized Repair Center. It does not apply to 
removal or installation of the Product any purchaser’s 
premises). During the “Parts” Limited Warranty period, there 
will be no charge for parts.  
You must ship your Polaris Gate Operator to Polaris Gate 
Operators during the applicable Limited Warranty period. This 
Limited Warranty excludes both parts and labor for batteries, 
antennas, and cosmetic parts (such as the Product housing). 
This Limited Warranty only applies to Products purchased in 
the United States. This Limited Warranty is extended only to 
the original non-consumer purchaser (“you” or “your”) of a 
new Product that was not sold “as is”.

  

 
Limited Warranty Service  

For assistance in the continental U.S.A. in obtaining the 
benefit of the Limited Warranty please carefully follow these 
steps:  
1) Complete carefully all troubleshooting procedures in the 
Maintenance and Troubleshooting Guide in this Manual.  
2) If you are still unable to solve the problem, contact Polaris 
Gate technical support at [email protected]
Please have the model and serial number of the Product 
available to give to the customer service representative. The 
customer service representative will provide further assistance 
or authorize repair or replacement, as appropriate.  
3) If repair or replacement is appropriate you will be given a 
return authorization number (RMA#). This RMA# must be 
visible on all documents and packages returned to Polaris Gate 
Operators.  
4) Carefully pack the defective Product or Product part in a 
sturdy shipping carton, include (i) a letter detailing the 
complaint, (ii) a daytime phone number where you can be 
reached, (iii) your name and address for any return, (iv) your 
sales receipt/proof of purchase, and (v) the

 

RMA# on all 

correspondence and the shipping carton.

 

 

5) Prepay the freight and insure the defective Product or 

Product part against shipping damage. Note that defective 
Products or Product parts shipped freight collect will not 
be accepted.  
6) Ship the carton to: Polaris Gate Operators, 8617 Paseo 
Alameda NE, Albuquerque, NM 87113.  

IF REPAIR OR REPLACEMENT IS NEEDED 
DURING THE LIMITED WARRANTY PERIOD, 
YOU WILL BE REQUIRED TO FURNISH A SALES 
RECEIPT/PROOF OF PURCHASE INDICATING 
DATE OF PURCHASE, AMOUNT PAID AND 
PLACE OF PURCHASE. YOU WILL BE 
CHARGED FOR THE REPAIR OF ANY PRODUCT 
OR PRODUCT PART RECEIVED WITHOUT 
SUCH PROOF OF PURCHASE OR FOR REPAIRS 
REQUESTED AFTER THE APPLICABLE 
LIMITED WARRANTY PERIOD.  
Limited Warranty Limitations and Exclusions  

This Limited Warranty ONLY COVERS failures due to 
defects in materials or workmanship, and DOES NOT 
COVER normal wear and tear or cosmetic damage. The 
Limited Warranty ALSO DOES NOT COVER damages 
which occurred in shipment, or failures which are caused 
by products not supplied by Polaris Gate Operators, or 
failures which result from accidents, misuse, abuse, 
neglect, mishandling, misapplication, modifications or 
alterations, faulty installation, connection to an improper 
power source, set-up adjustments, mis-adjustment of 
controls, improper maintenance, power line surges, 
damage from acts of God such as lightning, wind, fire, 
flood or insects, introduction of sand, humidity or liquids, 
commercial or rental use or service by anyone other than 
an Authorized Repair Center.  

THERE ARE NO EXPRESS WARRANTIES 
EXCEPT AS STATED UNDER “LIMITED 
WARRANTY COVERAGE”. POLARIS GATE 
OPERATORS IS NOT LIABLE FOR INCIDENTAL 
OR CONSEQUENTIAL DAMAGES RESULTING 
FROM THE USE OF THE PRODUCT, OR 
ARISING OUT OF ANY BREACH OF THIS 
LIMITED WARRANTY.

 (As examples, this excludes 

damages for lost time, lost calls or messages, cost of 
having someone remove or re-install an installed Product 
or Product part, travel to and from an Authorized Repair 
Center, etc. The examples listed are not an exhaustive or 
exclusive list, but are for illustration only). 

ALL 

EXPRESS AND IMPLIED WARRANTIES, 
INCLUDING ANY IMPLIED WARRANTIES OF 
MERCHANTABILITY OR FITNESS FOR A 
PARTICULAR PURPOSE, ARE LIMITED TO THE 
PERIOD OF THE LIMITED WARRANTY.

  

Some States do not allow the exclusion or limitation of 
incidental or consequential damages, so the above 
limitation or exclusion may not apply to you.  
Some States do not allow limitations on how long an 
implied warranty lasts, so the above limitation may not 
apply to you.  
This warranty gives you specific legal rights,

 

and you 

may also have other rights which vary from State to State.  

PARTS AND SERVICES WHICH ARE NOT 
EXPRESSLY COVERED BY THIS LIMITED 
WARRANTY ARE YOUR RESPONSIBILITY

Содержание 502

Страница 1: ...r Polaris Automatic Gate operator sometimes also referred to as the Product read this entire Installation Manual for information about Product safety matters and proper use of the Product Only use the Product for the purpose of operating a driveway gate Polaris 700 702 Polaris 500 502 ...

Страница 2: ...etting 22 Push to Open Limit Setting 24 Primary Secondary Gate Movement 26 Obstruction Sensitivity Set Up 27 Auto Close Timer 28 Transmitter Receiver 29 Accessory Hook Up Diagram 30 Exit Wand Hook Up Diagram 33 Photo Eyes Hook Up Diagram 34 Emergency Disconnect 36 Technical Specifications 37 Parts List and Illustrations 38 Troubleshooting Maintenance 40 List of Accessories 42 Warranty 43 Polaris A...

Страница 3: ... depends on proper installation and the manner of use or application all of which are beyond the control of Polaris Professional Products or the seller All such risks are assumed by the purchaser and by the purchaser s installation and use of the Product The Polaris Automatic Gate Operator is for use on driveway gates only The Product meets or exceeds the requirements of UL 325 the standard that r...

Страница 4: ...nded to service the general public Restricted Access Vehicular Gate Opener Class IV A vehicular gate opener or system intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public in which unauthorized access is prevented via supervision by security personnel Categories established by Underwriter...

Страница 5: ... is Type A an inherent means of entrapment protection The secondary means of entrapment protection in the Polaris Automatic Gate Operator is Type B1 the provision for the connection of a photo cell or other non contact sensor The gate operator s built in means of entrapment protection Type A may not be sensitive enough to prevent bodily injury in some circumstances Secondary means of entrapment pr...

Страница 6: ...1 Hinged edge of the gate and the fence post Entrapment Area 2 Between the gate and the gate post Entrapment Area 3 The path of the gate Entrapment Area 4 The space between the gate in the open position and any object such as a wall fence tree etc Entrapment Area 5 Pinch points between the operator and gate or post Area 2 Area 1 Area 3 Area 4 Area 5 Gate in open position Driveway ...

Страница 7: ...he control box OFF for ten seconds and back ON also deactivates the alarm Warning Signs and Labels Required Safety Precautions for Gates Warning signs alert people of automatic gate operation They are required when installing the Polaris Automatic Gate Operator If pedestrians will be in the area install a walkthrough gate for their use Warning Signs The warning signs must be installed on both side...

Страница 8: ...is check should only be made with the battery disconnected to prevent the gate from moving during the test 7 This is a VEHILCLE GATE ONLY Pedestrians must use a separate entrance 8 NEVER install any control device on the outside of the Polaris cabinet or in such a way that someone can reach through the gate to activate it 9 SAVE THESE INSTRUCTIONS CAUTIONS 1 NEVER operate the gate unless you can s...

Страница 9: ...Page 9 ...

Страница 10: ...Page 10 ...

Страница 11: ...Page 11 Bushings to be set between bottom side of actuator rod ends and mounting bracket ...

Страница 12: ...Page 12 ...

Страница 13: ...ling of the post to be installed You simply set it into the position and bolt it tight The correct angle is preset 3 1 2 Post Push to Open 3 1 2 Post Pull to Open AGA recommends using self tapping screws on flat plates as indicated after final setup is complete This will help to secure the universal bracket from shifting AGA recommends using self tapping screws on flat plates as indicated after fi...

Страница 14: ...illing of the post to be installed You simply set it into the position and bolt it tight The correct angle is preset 5 Post Pull to Open 5 Post Push to Open AGA recommends using self tapping screws on flat plates as indicated after final setup is complete This will help to secure the universal bracket from shifting AGA recommends using self tapping screws on flat plates as indicated after final se...

Страница 15: ...l receive the Amazing Gates Universal Pull and Push brackets and gate attach bracket s These brackets can be used with your exiting posts or any non Amazing Gates posts to include column mounting Though the Amazing Gates bracket system can be used on any post column setup the diagram shown below must be followed concerning geometry of pivot point and hinge point ...

Страница 16: ...Close 7 Battery OK 8 Battery Charging 9 Status 10 Safety Loop 11 Shadow Loop 12 Exit Loop 13 Radio Receiver Potentiometers 14 Stall Force Adjustment 15 Auto Close Adjustments Buttons 16 Cycle used as an input device 17 Set Limit 18 Learn Code 19 Power Save Fuses 20 15 amp Fuse 21 4 amp Fuse Connectors 22 Buzzer Connection 23 RF Board Connection ...

Страница 17: ...P Switch 4 Time of Soft Start Stop ON Max extended time of soft start stop operation OFF Extended time of soft start stop operation NOTE Only active if Block 1 DIP 3 is set to ON Block 2 DIP Switch 1 Single or Dual Gate ON Dual gate applications OFF Single gate applications Block 1 DIP Switch 2 Audible Motion Alarm ON Audible motion alarm enabled OFF Audible motion alarm disabled Block 1 DIP Switc...

Страница 18: ...up Follow local electrical codes Step 2 If using AC power to charge the battery connect wire to the control box as shown in fig 19 If charging battery with a solar panel s refer to Accessory Hook Up Diagram fig 32 on page 28 Connect wires from primary operator and secondary operator if installing on a dual gate to the control box as shown in fig 19 Wire should be buried in accordance with local co...

Страница 19: ...L ALL WIRING IS COMPLETED Step 4 Install the battery by placing the battery into the control box The control box can accommodate one or two batteries Warning Do not attempt to splice operator wires for the purpose of extending your wiring connections Doing so can void your warranty Contact technical support for recommended procedure 1 877 313 8902 Batte Second Battery not included Figure 22 Black ...

Страница 20: ... to indicate that the system is functioning properly Also used to indicate a user input during installation LED 10 SAFETY LOOP Lit when the safety loop contact is made LED 11 SHADOW LOOP Lit when shadow loop contact is made LED 12 EXIT LOOP Lit when an exit loop contact is made LED 13 RADIO RECVR Lit while transmitter button is pushed Power Save Mode Recommended for Solar Applications Polaris Auto...

Страница 21: ...Page 21 WIRING THE OPERATOR ...

Страница 22: ...osition Step 5 Again using the cycle button close the gate to verify it meets the desired location If the gate did NOT reach the desired closed limit proceed to step 6 Step 6 CLEARING THE CLOSED LIMIT SETTING a Return the gate to the fully open position b Press and hold the SET LIMIT button until two audible beeps are heard c Two audible beeps will verify the closed limit setting is now cleared Re...

Страница 23: ... limit position that was programmed in the previous steps The secondary gate will continue to close until you press the cycle button on the circuit board Step 6 Press and hold the SET LIMIT button until one audible beep is heard to acquire the closed limit setting fig 28 The STATUS light will turn on immediately upon pressing the SET LIMIT button The STATUS light will turn off and an audible beep ...

Страница 24: ...to the fully closed position Step 5 Again using the cycle button open the gate to verify it meets the desired location If the gate did NOT reach the desired open limit proceed to step 6 Step 6 CLEARING THE OPEN LIMIT SETTING a Return the gate to the fully closed position b Press and hold the SET LIMIT button until two audible beeps are heard c Two audible beeps will verify the open limit setting i...

Страница 25: ...tinue to open until you press the cycle button Step 6 setting secondary gate Set Block 2 DIP switch 6 to the ON position Press and hold the SET LIMIT button until you hear one beep to acquire the open limit setting fig 29 The STATUS light will turn on immediately upon pressing the SET LIMIT button The STATUS light will turn off and an audible beep will verify the open limit is now set Step 7 Press...

Страница 26: ...n Block 2 DIP 4 ON position Now determine which gate is desired to open first and close second Another DIP switch adjustment is required to set this For primary gate operator wired to operator 1 terminals to open first and close second Block 2 DIP 5 OFF position For secondary gate operator wired to operator 2 terminals to open first and close second Block 2 DIP 5 ON position The delay in opening a...

Страница 27: ...sensitivity or the amount of force the operator will apply to an obstruction before it automatically stops and reverses direction of the gate Adjust the sensitivity beginning at the factory default counter clockwise position Continue to incrementally increase the force until the gate can open and close without obstructing under its own weight NOTE The stall force may need to be increased in cold w...

Страница 28: ...CLOSE TIMER potentiometer The default position of the potentiometer is zero seconds Timer will activate after gates have completed one full cycle To increase the delay time turn the potentiometer clockwise NOTE Only active if Block 1 DIP switch 1 is in the ON position POLARIS STRONGLY RECOMMENDS THE USE OF A SAFETY DEVICE SUCH AS PHOTO BEAMS OR SAFETY LOOP WHEN AUTO CLOSE TIMER IS ACTIVATED ...

Страница 29: ...ut no more than five seconds Upon release the CHARGING LED will light the STATUS LED will stop blinking and an audible beep will occur verifying the circuit board is in the learn code mode Step 5 Press and hold the transmitter button until the CHARGING LED turns off the STATUS light blinks and an audible beep occurs Release the transmitter button The transmitter code is now set Step 6 Replace the ...

Страница 30: ...Page 30 Note Some accessories may require additional wire and or hardware and is to be supplied by the installer ...

Страница 31: ... System Fire Access Control Keyswitch Control Solenoid Lock 1 see page 30 Accessory Connections Strip Magnetic Lock 2 see page 30 Please refer to Magnetic Lock instruction manual for connection instructions Connections differ for 12v or 24v connection ...

Страница 32: ...Page 32 ACCESSORY HOOK UP DIAGRAM Wired Keypad Photo Eye Beams Victory PB 1200 Photo Eye Beams External Radio Receiver ...

Страница 33: ...Page 33 EXIT WAND HOOK UP DIAGRAM ...

Страница 34: ...or Attach the terminals in the emitter to those on the gate operator circuit board as shown below Use a direct burial type of control wire like sprinkler wire and position the emitter on the hinge side of the Use these instructions in combination with the NIR instructions that come with the photo eyes NIR Photo Brown Gray White Black Blue Black wire not used ...

Страница 35: ...screw terminals labeled plus and minus The RECEIVER has 5 terminals DO NOT use terminal 4 To connect the units to the gate operator circuit board see the drawing below Use a direct burial type of control wire like sprinkler IRB 4X Photo Eye Use these instructions in combination with the IRB 4X instructions that come with the ...

Страница 36: ...NCY DISCONNECT CAUTION The gate will move freely and uncontrolled when the gate operator is removed from the gate ONLY disconnect the gate operator when the control box power switch is OFF and the gate is NOT moving ...

Страница 37: ...tor 18 VAC transformer 18 0 to 22 0 VAC 12 V Battery 12 0 to 13 5 VDC 7 2Ah Charging Circuit 12 0 to 14 8 VDC Transmitter Receiver Frequency 433MHz Transmitter Range Up to 100 feet 90 meters varies greatly depending on gate surroundings POLARIS 500 502 Capacity 12 feet 200 pounds Stroke Length 19 inches Minimum Gate Length 60 inches POLARIS 700 702 Capacity 14 feet 300 pounds Stroke Length 24 inch...

Страница 38: ...Page 38 PARTS LIST AND ILLUSTRATIONS ...

Страница 39: ...Page 39 PARTS LIST AND ILLUSTRATIONS Secondary Gate Operator 40 ft cable Polaris 502 Polaris 702 Circuit Board Cabinet Dimensions 14 5h x 12 5w x 6 5d Control Box Transformer Battery ...

Страница 40: ... Will Not Close Automatically 1 Make sure dip switch 1 block 1 is in the on position 2 Adjust timer to preferred close time 3 Gate must complete one full cycle before timer is activated The gate s will not operate 1 Verify power switch is on 2 Verify the STATUS LED is blinking approximately once per second If not check battery connections and both 4A and 15A fuses 3 Verify SAFETY LOOP LED SHADOW L...

Страница 41: ... a gate gets to the desired closed open position Once this occurs set the limit for that gate by pressing the set limit button until it beeps once make sure dip switch 6 is set appropriately Cycle the gates back to the open closed position 5 With the gates in the open closed position cycle gates to close open once again This time stop the gates when the other gate gets to the desired stop location...

Страница 42: ... or close The access code can be easily modified Pin Lock The pin lock replaces the clevis pin when mounting the gate operator to the brackets It helps to prevent theft of the gate operator from the gate while allowing quick release of the operator In Ground Vehicle Sensor The vehicle sensor is buried near the gate and senses a vehicle that passes within its 12 foot range Once detected the gate op...

Страница 43: ... and address for any return iv your sales receipt proof of purchase and v the RMA on all correspondence and the shipping carton 5 Prepay the freight and insure the defective Product or Product part against shipping damage Note that defective Products or Product parts shipped freight collect will not be accepted 6 Ship the carton to Polaris Gate Operators 8617 Paseo Alameda NE Albuquerque NM 87113 ...