![Polargos Simple Move 101 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/polargos/simple-move-101/simple-move-101_manual_1571741026.webp)
26
EN
►
Recognition of photocells by the electronic system of the drive unit
when in sequential mode
Note:
In automatic closing mode, the photocells are recognized by the electronic system of the drive unit on
activation of the automatic closing mode (see page 21).
►
Removal of photocells
In case of isolation of the photocells:
- in sequential mode: repeat the procedure of recognition of the photocells by the electronic system of the drive
unit in sequential mode,
- in automatic closing mode: repeat the procedure of activation of the automatic closing mode as described on
page 21.
►
Obstructed photocells
If the photocells are obstructed during gate closing, the gate will stop and start moving in the reverse direction.
If the gate is closed and the photocells are obstructed, the gate will not open.
►
Safety rules
The photocell operation must be checked every 6 months. To do this, shield the photocell with one hand during
gate closing.
The gate should stop and open again.
[1].
Put the programmed remote control with 2 or 4 push-
buttons on the picture showing a target. Press remote
control push-button 1 until the AUTOMATIC
CLOSING indicator goes out and then
starts flashing.
Note:
After stage 1 is finished, successive
stages can be carried out in remote mode
(without placing the remote control on the
picture showing a target).
[2].
Press remote control push-button 2 until the
AUTOMATIC CLOSING indicator
goes
out, and then starts flashing.
[3].
Press remote control push-button 1 twice.
2
3
1
x2
Содержание Simple Move 101
Страница 1: ...Simple Move 101 CANTILEVER GATE DRIVE UNIT EN ...
Страница 12: ...12 EN Toothed bar Washer M6 Bar No 2 Start of assembly Bar No 3 Bar No 1 Screw M6x50 Bar No 4 lis ...
Страница 23: ...23 EN ACCESSORIES A cross section of conductors for individual types of devices TX RX concentric cable ...