Error Messages

The following table details the cause and subsequent response of the appliance to errors. 

The alarm message will end when the alarm trigger is no longer present, except PF1 and PF2 that require the appliance to be turned Off, then On again.

Technical Specifications

Electrical Wiring

POLAR appliances are supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard. 
The plug is to be connected to a suitable mains socket. 
POLAR appliances are wired as follows:

 Live wire (coloured brown) to terminal marked L

 Neutral wire (coloured blue) to terminal marked N

 Earth wire (coloured green/yellow) to terminal marked E 

All POLAR appliances must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.

Compliance

POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international, independent, and 
federal authorities.
POLAR products have been approved to carry the following symbol: 

Error Message 

(flashing)

Cause

Appliance Response

Action

HtA

The inner temperature exceeds 
the set maximum temperature 

Display flashes
Alternating error message and current temperature

Check Troubleshooting Guide
If problem persists call POLAR agent or 
qualified Technician 

LtA

The inner temperature exceeds 
the set minimum temperature 

Display flashes
Alternating error message and current temperature

Check Troubleshooting Guide
If problem persists call POLAR agent or 
qualified Technician

PF1

Short circuit or interruption of 
the thermostat probe input line

Display flashes

Compressor operates as specified by 
parameter ‘=

23

PF2

Short circuit or interruption of 
the evaporator probe input line

Display flashes

Defrost as specified by parameters 

d8

 and 

d9

HLA

Inner temperature greater than 
90°C

Display flashes
Alternating error message and current temperature

Call POLAR agent or qualified Technician

LLA

Inner temperature lower than 
-45°C

Display flashes
Alternating error message and current temperature

Call POLAR agent or qualified Technician

Model

Voltage

Power

Current

Temperature

Range

Capacity

(litres)

Refrigerant

Dimensions

H x W x D (mm)

Weight 

(Kg)

G596

230V 50Hz 

340W

1.5A

-2°C to 10°C

282

R134a 240g

850 x 1360 x 700

98

G597

230V 50Hz

340W

1.5A

-2°C to 10°C

417

R134a 240g

850 x 1795 x 700

134

G598

230V 50Hz

450W

2A

-2°C to 10°C

563

R134a 250g

850 x 2230 x 700

153

G599

230V 50Hz

1000W

4.35A

-10°C to -20°C

282

R404 300g

850 x 1360 x 700

103

G600

230V 50Hz

1000W

4.35A

-10°C to -20°C

417

R404 260g

850 x 1795 x 700

136

G601

230V 50Hz

1000W

4.35A

-10°C to -20°C

563

R404 320g

850 x 2230 x 700

155

G621

230V 50Hz

340W

1.5A

-2°C to 10°C

417

R134a 240g

900 x 900 x 700

140

G622

230V 50Hz

340W

1.5A

-2°C to 10°C

368

R134a 250g

850 x 1365 x 700

107

U636

230V 50Hz

250W

1A

-2°C to 10°C

240

R134a 165g

850 x 900 x 700

70

U637

230V 50Hz

250W

1A

-2°C to 10°C

240

R134a 165g

850 x 900 x 700

71

U638

230V 50Hz

250W

1A

-2°C to 10°C

240

R134a 165g

850 x 900 x 700

72

Содержание G596

Страница 1: ...Stainless Steel Counter Refrigerators Freezers Models G596 G597 G598 G599 G600 G601 G621 G622 U636 U637 U638 ...

Страница 2: ... 1 Fitting the Shelves Floor Guards 1 Operation 1 Storing Food 1 Turn On 1 Control Panel 1 Lock Unlock the Control Panel 1 Enter the Parameter Menu 2 Manual Defrost 2 Cleaning Care Maintenance 3 Cleaning the Condenser 3 Disposal 3 Troubleshooting 3 Error Messages 4 Electrical Wiring 4 Compliance 4 ...

Страница 3: ...ng is included POLAR prides itself on quality and service ensuring that at the time of packaging the contents are supplied fully functional and free of damage Should you find any damage as a result of transit please contact your POLAR dealer immediately Installation 1 Remove the appliance from the packaging Make sure that all protective plastic film and coatings are thoroughly removed from all sur...

Страница 4: ...e The defrost duration can be overridden by parameter d10 below if the cut off temperature is reached before the end of the defrost duration 0 999 minutes d10 Defrost Cut off Temperature Set the defrost cut off temperature 45 C to 50 C d11 Additional Cut off Defrost Period Set an additional amount of defrost time after the defrost cut off point has been reached if required 0 99 minutes d12 Delayed...

Страница 5: ...ot working The unit is not switched on Check the unit is plugged in correctly and switched on Plug and lead are damaged Call POLAR agent or qualified Technician Fuse in the plug has blown Replace the fuse Power supply Check power supply Internal wiring fault Call POLAR agent or qualified Technician The appliance turns on but the temperature is too high low Too much ice on the condenser Defrost the...

Страница 6: ...erature exceeds the set minimum temperature Display flashes Alternating error message and current temperature Check Troubleshooting Guide If problem persists call POLAR agent or qualified Technician PF1 Short circuit or interruption of the thermostat probe input line Display flashes Compressor operates as specified by parameter 23 PF2 Short circuit or interruption of the evaporator probe input lin...

Страница 7: ...Notes ...

Страница 8: ...POLAR Telephone Helpline 44 0845 146 2887 POLAR Fourth Way Avonmouth United Kingdom BS11 8TB ...

Отзывы: