11
UK
Troubleshooting
If your POLAR appliance develops a fault, please check the following table before making a call to the
Helpline or your POLAR dealer.
Fault
Probable Cause
Solution
The appliance is not
working
The unit is not switched on
Check the unit is plugged in correctly and
switched on
Plug or lead is damaged
Call POLAR agent or qualified Technician
Fuse in the plug has blown
Replace the fuse
Power supply
Check power supply
Cabinet temperature is
too Warm
Doors are not shut properly
Check doors are shut and seals are not
damaged
Appliance is located near a
heat source or air flow to the
condenser is being interrupted
Move the appliance to a more suitable
location
Ambient temperature is too high
Increase ventilation or move appliance to a
cooler position
Insufficient airflow to the fans
Remove any blockages to the fans
The set temperature is too high
Set a lower temperature
Low refrigerant level
Call POLAR agent or qualified Technician
Condensation on the
Cabinet and/or floor
Gasket not sealing well
Clean, repair, or replace the gasket as
necessary
Technical Specifications
Model
Voltage
Power
Current Temperature
Range
Refrigerant
Dimensions
H x W x D mm
Weight
(kg)
GE632 230V~ 50Hz 150W
1.1A
2°C ~ 8°C
R600a (55g)
1312 x 612 x
810
63
GE633 230V~ 50Hz 250W
1.6A
2°C ~ 8°C
R290 (95g)
1438 x 1247 x
620
97
GE632-GE633_ML_A5_v1_20210423.indb 11
GE632-GE633_ML_A5_v1_20210423.indb 11
2021/4/23 13:26
2021/4/23 13:26
Содержание GE632
Страница 81: ...GE632 GE633_ML_A5_v1_20210423 indb 81 GE632 GE633_ML_A5_v1_20210423 indb 81 2021 4 23 13 27 2021 4 23 13 27...
Страница 82: ...GE632 GE633_ML_A5_v1_20210423 indb 82 GE632 GE633_ML_A5_v1_20210423 indb 82 2021 4 23 13 27 2021 4 23 13 27...
Страница 83: ...GE632 GE633_ML_A5_v1_20210423 indb 83 GE632 GE633_ML_A5_v1_20210423 indb 83 2021 4 23 13 27 2021 4 23 13 27...