*3) PID function with exit on 17-18 terminals to control of one solid-state relay (SSR).

*1) For more details see Operating Diagrams.

*4) Reffered to PID function. The correction of autotuning is set every 16 x IntE.
*5) The temperature setting that can be programmed with TEMP key must be included among

*7) You can correct the readings on the sensor (or -).

r.AL.

r.COL

HEAT

1/2

1/2

OFF

r.AL.

* ALARM outputs available only

t.SEt

r.HEA

r.vEn

d.HEA

ON

OFF

VENT

d.vEn

1/2

1/2

ON

OFF

COOL

d.COL

1/2

1/2

ON

OFF

0.2°

0.1°

0.1°

ON

MIN

ALARM

0.2°

0.1°

0.1°

ON

OFF

MAX

ALARM

Function on the ground of the temperature.

STATE INDICATION LAMPS

The light situated at the bottom of the display shows the state of the controller:

*2

 Available only with HPAL optional slot.

Lamp.

State

N° Relay

Contacts

HEAT

HEAT ON output

1

3-4

COOL

COOL output

2

5-6

VENT

VENT ON output

  3

 *1

7-8

HUM

HUM ON output

4

9-10

MIN ALARM

MIN ALARM ON output

  6

 *2

   3-4-5 *

MAX ALARM

MAX ALARM ON output

   7 

*2

   6-7-8 *

 CYCLE OFF

CYCLE OFF output

  3 

*1

7-8

CYCLE ON

CYCLE ON output

  3 

*1

7-8

COSt PROGRAMMING (System constants)

OPERATIVE DIAGRAMS

with HPAL optional slot.

*6)OPt.H =1 : psychrometric sistem (wet bulb): to call for a SXPS probe.

OPt.H =2 4-20mA sensor: to call for a HALI power pack.
The psychrometer-system obtained value can be recognized with the classic curve.

*

*

these values.

*2) If CYCL=0 relay N.3 works as VENTILATION output (indicated by VENT lamp).

If CYCL=1 (1 cycle/day) to CYCL=1720 (period cycle 2 minutes) VENTILATION operations
are excluded and CYCLE timer lamps lights indicating status of relay N.3 (closed during ON
duration). CYCLE timer is saved in order to continue counting after line blackout.

Excluded if
C Y C L > 0
(see COSt)

*1

 If CYCL=0 (see COSt) relay N.3 works as VENTILATION output (indicated by VENT lamp).

If CYCL=1 (1 cycle/day) to CYCL=1720 (period cycle 2 minutes) VENTILATION operations are excluded
and CYCLE timer lamps lights indicating status of relay N.3 (closed during ON duration). CYCLE timer
is saved in order to continue counting after line blackout.

r.HEA

-0.2°  °C HEAT setting shift reffering to  t.SEt.

*1

r.vEn

0.2°

 °C VENT setting shift reffering to  t.SEt.

*1

r.COL

0.4°

 °C COOL setting shift reffering to  t.SEt.

*1

d.HEA

0.2°

 °C HEAT differential.

*1

d.vEn

0.2°

 °C VENT differential.

*1

d.COL

0.2°

 °C COOL differential.

*1

r.AL._

-0.5°  °C MIN ALARM setting shift reffering to  t.SEt.

*1

r.AL.-

0.3°

 °C MAX ALARM setting shift reffering to  t.SEt.

*1

CYCL

0

  Number of daily cycles/VENT exclusion

*2

durA

0'

  Minutes ON duration of daily cycles

*2

ProP

1.0°

 °C HEAT PID proportional band.

*3

IntE

8.0"

  Time seconds of cycle and of PID integration.

*3

dEri

4.0"

  Time seconds of PID derivative.

*3

SELF

=1

 Autotuning (=0 disable, =1 enable).

*4

b.Hun

2.0H   %RH humidification proportional band

*1

CYC.H

0"

 Seconds of humidification cycle.

*1

SEt._

35.0°  °C minimum set ( t.SEt) impostation.

*5

SEt.-

38.2°  °C maximum set ( t.SEt) impostation.

*5

OPt.H

=1

 Humidity sensor type

*6

tEnP

=1

 Temperature representation (=1 °C,  =2 °F).

*7

Ad.tE

 0.0°  °C Input temperature sensor correction (+ or -).

*7

Ad.tu

 0.0°  °C Input temperature wet sensor correction (+ or - ).

*7

Ad.rH

0.0H  %Rh Input humidity sensor correction (+ or -).

*7

Function on the ground of the humidity.

PROBE HUMIDITY 

 *2

b.Hun

HUM

 ON

 OFF

1/2  b.Hun

1/2  b.Hun

H.SEt

CYC.H= 0

CYC.H = 1"...999"

 

100%

b.Hun

HUM

 OFF

H.SEt

 

75%

 

50%

 

25%

 

0%

*1 Relay's operation computed
with 0.1 second resolution and
actioned minimum 0.5 second.

ON

ON

CYCL

CYCL

ON

ON

CYCL

OFF

ON

*1 Relay's ouput in the
time.

ON

ON

*2

 The environment

humidity obtained value
can be done with wet
b u l b ' f u n c t i o n
(psychrometer system),
or with 4-20mA electronic
probe.

PROBE TEMPERATURE

PROBE HUMIDITY 

 *2

These settings refer to the operation mode of the system and must be made on
initial startup. Press - / + at the same time for at least one second: the message
C.O.S.t. will be displayed.
Press than repeatedly ALARM until the message regarding the chosen variable
is displayed (see table below) : value of variable and message will be displayed.
Press + or - to set a new value and then press ALARM to confirm.
The next system constant will then appear.
You can press ALARM for at least 2 seconds to exit and return to the Run Mode.