VIEW OF ALARM SETTINGS.

The settings of alarm temperatures can be only see on
display; to obtain this press ALARM (key lamp flashes):
this message will be displayed instead of the                                     °
Set Minimum alarm temperature value
 .

HP46

SL 6.0

Handbook

Egg-Discloser

INSTALLATION

How to connect the contacts.
Connect terminals on the  terminal  block (contacts up to
4AMP.AC1)  to the loads as shown in  the diagram.

HP46

230V LINE*

HEATING

HUMIDIFICATION

VENTILAT./CYCLE

SX TEMPERATURE

PROBE

SXPS TEMP. 

PROBE

 (wet sensor)

+

-

RELAY COMMAND

solid state (PID)

SSR 5V DC.

For future use

COOLING

With TEMP key lamp light (press TEMP key) ambient temperature is
displayed. With HUM key lamp light (press HUM) ambient humidity is
displayed (if the humidity is obtained with "wet bulb" , pressing HUM for
more than 1 second on display will appear the message t.vEt in turn of
obtained value of temperature probe "wet bulb".

MAIN SETTING (Run Mode)

Press TEMP (key lamp flashes):
this message will be displayed instead of the
° Set temperature value  .
Press  +  or  -  to modify, press TEMP  to confirm.

HUMIDITY SETTING.

Press HUM (key lamp flashes):
this message will be displayed instead of the
%RH Set Humidity value .
Press  +  or  -  to modify, press HUM  to confirm.

Press ALARM : at this point this message will be displayed
instead of the ° Set Maximum alarm temperature value .
Press ALARM  to exit.

TEMPERATURE SETTING

AMBIENT TEMPERATURE AND  HUMIDITY VIEWING

VIEWING TEMPERATURE RECORDING

Press  +

: will be displayed followed by
°Maximum Temperature Recording.

Press  -  :

will be displayed followed by
°Minimum Temperature Recording.

Values are permanently stored in the memory: for deleting all values in the memory keep
pushed key for more than 3 seconds: CLEA message will appear on display before
clearing operation.

OUTPUT

OUTPUT

OUTPUT

OUTPUT

* Other power voltage   if you required.

How to connect the line.
Connect 220V line on terminals L-N .
Protect supply with adequate fuse.

How to connect the sensors
Connect the provided sensor as shown in the  diagram.
For  remote  connections  use  a standard 0.5-square millimeter
two-pole wire (one for each sensor)
, taking great are over  the
connections,  by insulating and sealing the joins carefully. -O.C.-
is displayed when the temperature sensor wiring is open,  -S.C.-
is displayed when the temperature sensor wiring is short circuit.

PRESET PROGRAMS (Bootstrap).

This processor is already programmed with the following (variable) settings.
To return to these settings at any time you may:

Power off the processor, press ALARM key and keep it pressed giving power on: boot
message will be displayed (release now MAX VENT key).
 t.SEt   =  37.7°      H.SEt  =  80.0H     AL._ _=37.2     AL.--=38.0
The COSt values are shown in COSt paragraphs.

OPt.H=2  electronic humidity probe connection.

OPt.H=1  psychrometer system humidity connection.

How to connect humidity-psychrometer system (wet bulb).

13 14

How to connect 4-20mAelectronic  humidity probe.

SXPS: temperature probe for
wet bulb (psychrometric
system). Attention: deep
only the terminal side of the
wetting cover
.

4-20mA sensor probe connection

13 14

-

+ +

-

4-20mA

probe

HALI

power pack

R

R= 100 ohm resistor

wetting cover

This water-container is not
an item of our production.

As it company policy to continually improve the products the Manufacturers
reserve the right to make any modifications thereto without prior notice. They
cannot be held liable for any damage due to malfunction.

10.12.12

MANUAL MODE

In some start-up conditions may be useful to work in "manual" mode:
Power off the processor, press   key and keep it pressed giving power on: HAnd  message
will be displayed (release now  +  key).
Push  +  until is displayed number required to be handed (see table State indication lamps )
and push ALARM for activing relay.
Pushing again  +  for increase relay number previous relay is disactivated.
You can press ALARM key for a least two seconds to escape and return to the Run Mode.