Overall dimensions
Presentation
Use
Usage Manual
• Operating and handling
Quick ON/OFF shutoff valve. Pull the handle to the
rear to obtain the maximum flow rate.
The flow rate and flush is adjusted by rotating the
flow rate adjustment ring. The available flow rates
are engraved on the flow rate adjustment ring. By
rotating the ring to the desired setting, the flow
rate will be set to this value at the 6 bar (87psi)
reference pressure. A tactile indicator permits the
user to know the flow setting even in total darkness
and while wearing firefighting gloves (conform to EN
659).
This ring also has a position marked PURGE or
FLUSH which permits the removal of particles which
could interfere with the proper hydraulic operation
of the nozzle.
Selectable stream pattern: a continuous rotation of
the head ring allows the user to progress from a
straight stream to a narrow spray "Flash Over", to
a full fog diffusion cone of 130° forming a wall of
water. Tactile and visual indicators permit the user
to know the type of stream even in total darkness
and while wearing firefighting gloves.
NARROW SPRAY
STRAIGHT STREAM
FULL FOG DIFFUSION
• Before placing under pressure
- 1 -
Check that no parts are damaged or missing.
- 2 -
Check that the fire nozzle is correctly connected to a water supply.
Note :
To obtain optimal performance, respect the following limits:
- Maximum Flow rate : 500 l/min
- Usage Pressure : 6 bar or 87 PSI