Aug/07
MN2036400001
10
(Just a Bunch Of Disks) array. Although JBOD doesn’t offer other
RAID functionality, it makes the hard disks appear to be a single one
by combining the drives into one larger logical one without any
capacity loss.
Rebuilding a Failed Mirror Set
When a failure to one member occurs, you will be notified by the
RAID BIOS during boot. The steps below will guide you in rebuilding
a failed mirror set.
1.
Replace the failed drive(s) with one of equal or greater capacity,
then start the computer.
2.
During boot press
Ctrl+S
or
F4
to enter the RAID BIOS.
3.
Select
Create RAID Set
press
Enter
.
4.
Select
SPARE DRIVE
, then press
Enter
.
5.
Select the single hard drive then press
Enter
.
6.
Input RAID size, press
Enter
. When asked
Are You Sure(Y/N)?
,
Press
Y
to confirm.
7.
Select
Rebuild Raid 1 Set
, press
Enter
.
8.
When asked
Are you sure(Y/N)?
, press
Y
confirm. The mirror
will begin rebuilding. Do not interface with process.
9.
When rebuilding is finished, press
Ctrl+E
.