EN
4
For normal operation detector must be away from places with frequently temperature changes and air
flows fast. Please don’t put your detector near window, air conditioner, fluorescent lamp, heating devices,
fridges, oven, stove, sunshine, etc. Also do not install 2 detectors in the same zone to avoid interference and
fault alarm.
PRODUCT TESTING
A. After installation of the battery, the device will self-check 30 seconds and then go to test mode, please
walk around in the detection zone from left to right or right to left, observing the LED’s flashes,and make
sure the device is detecting movement and working normally.
B. The LED indicator flashes once when detect the movement of human body.
C. Adjust the height and the angle of the device to the best detection range.
DETECTION RANGE DIAGRAM
Look down
Side view
TECHNICAL PARAMETERS
Operating voltage: 3V / 2xAAA alkaline bateries
Detection range: 8m ~ 12m (25
oC)
Working current: ≤ 25mA
Working temperature: -10
o
C ~ 55
oC
Static current: ≤ 15mA
Installation way: Wall hanging
Emission frequency : 433 Mhz
Installation height: 1.8 ~ 2.2m
Transmitting power: ≤ 10 dB
Detection degree: 110
o
Emission distance : ≥80m(in open air)
Dimensions: 105*40*26mm
TROUBLE SHOOTING
Failure
Solution
LED failed
Check battery installed well or not
Check the power of battery run out or not
Check jumper J3 whether inserted or not
LED flashes 3 times periodically
Low voltage, please replace the battery
Emission distance gets closer
The battery is running out
No response for detecting
Jumper cap J4 to be sleeping mode or not