background image

17

17

when fully coded.

Ÿ

All  other  detectors

except  the  one  you  want  to  program

must  be  off  for  the 

programing to take place

.

Ÿ

The  PIR  detector  can  only  be  installed  indoor.  The  rate  of  false  alarm  is  greatly 
influenced  by  the  installation  position.  The  best  installation  height  is  about  2-2.2 
meters from ground.

Ÿ

Avoid installing facing the windows, air conditions, fire stove, and sun light because 
the temperature difference is big and air velocity is fast in these places.

Ÿ

When using the PIR detector which is not pet-friendly, please put the pets in the place 
in which can not be detected by the PIR detector in the status of arm.

Ÿ

If the light of the PIR detector flashes means the battery is not enough and needs to be 
changed immediately.

Delete detectors

 

In the status of disarm, press [SET] button lightly, the host will make a short 

beep,  the  7  blue  LED  light  will  be  on  and  then  voice  prompts  “enter  setup,  remote 
controller coding”. Press [SET] button lightly again, then the first blue LED light will be on 
and the voice prompts “detector coding”. Then long press [SET] button right now, all the 
detectors in the defense zone 1 will be deleted. Press [SET] button lightly again, then the 
second blue LED light will be on, the voice prompts “detector coding”. Then long press 
[SET] button right now, all the detectors in the defense zone 2 will be deleted;   The 
method of deleting detectors of other defense zones is same.
Caution: If 10 detectors are coded into one zone, delete any detector from this zone, all 
detectors in this zone will be deleted. 

Zone names

 

You can set a name for each of the 10 zones to identify easily the alarm location. 

 

To  set  zone  names  select  „Zone  names“  app  option  or  send  a  SMS  with: 

programming pa [90] + zone number (01-07) + zone name (30 characters) + # .

For example:

 to set the name „main entrance“ to zone 3 send SMS: 88889003main 

entrance# . 

Note:

 

Ÿ

The app is made for 99 zones alarm systems, for this model you can only name the 
first 7 zones for the 7 wireless zones and the last 3 for the 3 wired ones. 

Record zone names
 

To record zone names select „Record zone names“ or send SMS: 

Ÿ

programming pa [92] + zone number (01-07) + [1] + # to record the zone’s 
name then speak to the control unit. The recording lasts10 sec. After that the unit will 
replay the recording.

Ÿ

programming pa [92] + zone number (01-07) + [2] + # to delete recording

Ÿ

programming pa [92] + zone number (01-07) + [3] + # to listen the recording

Set alarm address

 

If you have multiple alarm systems you can set the address for each of them to 

EN

Содержание Safe House PG300

Страница 1: ...Sistem de alarma wireless PNI Safe House PG300 Manual de utilizare...

Страница 2: ...dispecerat O iesire de tip releu NO NC 6 numere de telefon pentru apelare si 3 numere pentru SMS in cazul unui eveniment Armare dezarmare intercom si monitorizare sistem de la distanta Programare indi...

Страница 3: ...tuati conexiunile in functie de tipul detectorului utilizat 4 Pentru setarile zonelor din aplicatia dedicata zona 1 cablata corespunde zonei 97 din aplicatie zona 2 cablata corespunde zonei 98 din apl...

Страница 4: ...30xxxx xxxx parola noua formata din 4 cifre SMS schimbare parola programare 888831xxxx xxxx parola noua formata din 4 cifre Exemplu pentru a schimba parola de programare din 8888 in 0000 trimiteti com...

Страница 5: ...ea pentru a trimite un semnal catre unitatea de comanda Aceasta va prelua semnalul si va con rma programarea telecomenzii prin mesajul vocal coding completed Pentru a mai programa inca o telecomanda a...

Страница 6: ...re tineti cont ca acestia nu sunt imuni la animale asa ca daca armati sistemul indepartati animalele din zona protejata Stergere detectori Cand sistemul este dezarmat apasati scurt butonul SET unitate...

Страница 7: ...ntru a inregistra vocal adresa alarmei apoi rostiti adresa spre unitatea de comanda Inregistrarea dureaza 10 sec Dupa nalizarea inregistrarii unitatea o va reda in difuzorul incorporat parola programa...

Страница 8: ...atie sau trimiteti un SMS ce contine parola programare 45 timp intarziere 001 180 sec Exemplu pentru a seta o intarziere alarma de 80 sec trimiteti mesajul 888845080 Setare timp activare sirena Pentru...

Страница 9: ...tru a seta data 26 08 2016 ora 16 00 00 trimiteti mesajul 88883220160826160000 Armare dezarmare automata Sistemul va permite programarea a 3 armari si 3 dezarmari automate Programare armare automata a...

Страница 10: ...alarma pentru a trimite un semnal ce va receptionat de sirena ce va con rma printr un sunet scurt Operare programare sistem prin apel telefonic Toate setarile de mai sus pot efectuate si print un ape...

Страница 11: ...cifra 1 de la tastatura Revenire la setarile din fabrica a Pentru a reseta sistemul de alarma la setarile din fabrica dezactivati bateri de rezerva apoi deconectati alimentarea principala a sistemului...

Страница 12: ...reless nu suna veri cati daca sirena este alimentata Nu exista semnal GSM veri cati cartela SIM sa e introdusa corect veri cati cartela SIM sa nu necesite PIN veri cati daca unitatea de comanda functi...

Страница 13: ...12 12 Wireless alarm system PNI Safe House PG300 User manual...

Страница 14: ...urity dispatch One NO NC relay output 6 phone numbers for voice warnings and 3 for SMS Remote arm disarm intercom and monitor Individual programing for each zone Built in backup battery Support wirele...

Страница 15: ...se or normally open The users can connect the wire according the wireless detectors or as own requirement 4 Attributes setting of APP wireless defense zones the wired zone 1 is corresponded to the def...

Страница 16: ...rd SMS for changing the programming password 888831xxxx xxxx new 4 digit password For example to change the programming password from 8888 to 0000 send the SMS command 8888310000 ATTENTION If you chan...

Страница 17: ...ir the second remote controller right now Caution The host can pair at most 8 remote controllers The method of pairing other remote controls is the same NOTE If no button is pressed for 30 sec the sys...

Страница 18: ...button lightly again then the second blue LED light will be on the voice prompts detector coding Then long press SET button right now all the detectors in the defense zone 2 will be deleted The metho...

Страница 19: ...1 Alarm mode 1 real time 2 delay default delay is 40 sec 3 24 hours 4 bypass Zone type 1 SOS 2 re 3 gas 4 door 5 hall 6 window 7 balcony 8 bypass Siren 0 activate siren on alarm 1 do not activate sire...

Страница 20: ...option or send SMS programming password 77 0 1 0 disable function 1 you will receive a SMS every time you arm or disarm the alarm system Enable disable key sound not available for this model SMS warn...

Страница 21: ...de number 4 digits The default encode number is 0000 Enlist wireless siren the alarm system can only command the enlisted sirens To enlist a wireless siren in the alarm system set the siren in program...

Страница 22: ...tory default settings To reset settings to factory default turn off the backup battery then remove unit power Press and hold SET button while connecting the power All LEDs will turn on you will hear t...

Страница 23: ...MS arm send SMS operation password 2 App arm EN System home arm Remote control home arm NOTE this function is only available if you enabled it in programming App home arm SOS alarm in this case of ala...

Страница 24: ...ouldn t check if the main unit is on backup battery and if this is not charged check the GSM signal in the area with a phone Phone programming does not work check GSM signal try another SIM card try w...

Отзывы: