Operating Instructions 

Safety Requirements 

 

1.  WEAR SAFETY GLASSES

 and safety shoes for protection against foreign objects.  

2. NEVER

 use a Hammer with a loose head or splintered handle.  

3. USE 

ONLY

 nails from Porta-Nails, Inc.  

4. 

Air supply hoses should have a minimum working pressure rating of 150 PSI or 150 
percent of the maximum pressure produced in the power source, whichever is higher. 

5. 

Check all hoses before connecting to ensure that they are free from dirt, grit, or 
particles that could alter the performance of the tool. 

6. 

An airline Filter and Regulator are required. 

7. 

The 

PORTAMATIC®

 pneumatic Nailer requires 

Clean, Dry Air

.  

DO NOT USE 

IN-LINE OILERS WITH THE

 

PORTAMATIC®

.

 Dust, dirt and other particles 

in the system can cause premature wearing of the major components.  Cylinder, piston, 
and o-rings are especially sensitive to wear caused by dirt abrasion. 

8. 

Adjust the airline Regulator to 

90-95 PSI

. Be sure that the tool is not pointed at you or 

others when it is connected to the air supply source.  

Note:

 Some materials may require a higher pressure of 95-100 PSI in order to 

countersink the nail. 

9. NEVER

 use a defective tool. Replace worn or damaged parts immediately. Be sure 

that the Safety Trigger and operating mechanisms operate correctly and that all screws 
and seals are securely tightened at all times. 

 

Installing A Fitting 

 

 

Before using the 

PORTAMATIC®

 Nailer, a 3/8” NPT Fitting must be installed.  The 

PORTAMATIC® 

Nailer has an adapter installed to accept a 3/8” NPT fitting.  This 

provides the owner the advantage of installing the preferred 3/8” NPT Fitting of choice.  
This allows the freedom to use any configuration of quick connect 3/8” NPT Fitting.  
Install the 3/8” NPT Fitting into the supplied adapter and gently tighten. 

IMPORTANT: 

The bottom hole of the 

PORTAMATIC®

 that is plugged should 

NEVER

 be removed.  If plug is removed, the 

PORTAMATIC®

 Nailer will not perform 

correctly and serious damage may occur. 
 
 

Содержание Portamatic

Страница 1: ...nfo porta MAIL info porta MAIL info porta nails com nails com nails com nails com OWNER S MANUAL PORTAMATIC Pneumatic Nailer For Tongue and Groove Solid Wood Hardwood Laminate Flooring Roof Decking an...

Страница 2: ...rrants them to be free from defects in materials and workmanship for 2 years In the unlikely event that a problem occurs return the product to our plant freight prepaid and allowed so that a determina...

Страница 3: ...L CONTAINS FASTENERS Do not activate the tool unless the tool is placed firmly against the work piece 11 NO HORSEPLAY Do not point the tool toward yourself or anyone whether it contains fasteners or n...

Страница 4: ...Nailing 9 16 25 32 and 33 32 Hardwood Tongue and Groove Flooring See Shoe Accessory Applications section PORTAMATIC ACCESSORY SHOE APPLICATIONS FIGURE 1 FIGURE 2 Face Nailing Accessory Shoe Cat No 501...

Страница 5: ...ION TO AND FROM FACE NAILING FIGURE 5 Tongue and Groove Flooring Shoe Cat No 50111 FIGURE 6 Face Nailing Shoe Cat No 50113 Loosen or remove Flange Nuts Ref No 33 with Wrench and Shoe Screw Ref No 50 t...

Страница 6: ...y from sparks or a sliver of metal that might break away if this should occur 8 If a nail is driven on top of another or a jam occurs refer to the Clearing a Jam section of the manual on page 9 9 Slid...

Страница 7: ...on 8 Adjust the airline Regulator to 90 95 PSI Be sure that the tool is not pointed at you or others when it is connected to the air supply source Note Some materials may require a higher pressure of...

Страница 8: ...ted to power source Squeeze Safety Lever to enable the Nailer Releasing the Safety Lever re engages the Safety and renders the Nailer in operable 5 To operate tool depress Safety Trigger while tool is...

Страница 9: ...occurred repair immediately before connecting to the power source and continuing 5 Close Gate by placing the Gate Clip Wire over the two hooks of the Guide as shown and press down to seat and lock the...

Страница 10: ...move Extension Handle Ref No 15 Pg 17 from Main Body and Main Valve Housing Ref No 46 2 Remove Main Valve Housing Screws 4 and remove Main Valve Housing 3 Check the Head Gasket Ref No 6 to ensure prop...

Страница 11: ...equivalent Do not use greases that cause O Rings to swell The use of these types of greases may prevent Nailer from operating properly NEVER USE OIL FOR LUBRICATION FIGURE 11 Main Valve O Ring is used...

Страница 12: ...Ring is used on the I D groove of the Cylinder Discharge Valve Grease O rings FIGURE 14 Valve Body O Ring is used on the sealing groove of the Valve Body Grease O ring FIGURE 15 Driver Blade Piston A...

Страница 13: ...ces the Magazine Side of the Guide O RING Removing and Re Installing the Cylinder Assembly 1 After removing the Extension Handle and Main Valve Housing remove the Head Gasket Valve Body Assembly and t...

Страница 14: ...Cap Brown Not Shown 50170 Safety Glasses Not Shown 50038 Case PORTAMATIC Not Shown 42623 Porta Nails 10 packages of 1000 2 Nails RECOMMENDED EQUIPMENT Air Compressor 1 1 2 HP approximately 5CFM at 10...

Страница 15: ...ension Handle Assembly W Safety Includes 39 40 45 16 50402 Pusher Pull Screw 17 50062 Spring Constant Force Screw Ref 18 18 50064 Screw Constant Force Spring 19 50413 Pusher Assembly Includes 16 25 38...

Страница 16: ...0177 Screw Face Shoe 43 50154 Screws Magazine Retainer Bracket 3 ea 44 50155 Washers Valve Housing Screws 4 ea 45 50161 Spring Safety 46 50162 Valve Housing Assembly 47 50163 Ram Head Assembly W Cap S...

Страница 17: ...17 24 25 16 38 19 27 28 26 29 20 18 37 17 43 39 45 35 1 2 53 15 2 1 5 12 46 44 40 10 42 50 32 50 51 31 50 22 49 14 6 23 21 34 4 11 7 9 48 33 36 52 30 47 54 3 13 8 41...

Страница 18: ...sly done If Rail has already been turned previously replace Rail Nailer is shooting two nails Screws holding Magazine Ref 28 may be loose preventing Rail Ref 26 from being held properly in place Tight...

Страница 19: ...e Return Spring Washers Ref 3 are not damaged Replace if needed Check for smoothness and free movement of the Main Valve Ref 41 in the Valve Housing Ref 46 If too tight replace the O Rings on the Main...

Отзывы: