12
Dry Contact Signal
There is one dry contact (3A/250VAC) available on the rear panel. It could be used to deliver signal to external
device when battery voltage reaches warning level.
Unit Status
Condition
Dry contact port
Power Off
Unit is off and no output is powered.
Close
Power On
Output is powered from Utility
Close
Output is
powered
from Battery.
Program 01
set as Utility
Battery voltage < Low DC
warning voltage
Open
Battery voltage > Setting value
in Program 21 or battery
charging reaches floating stage
Close
Program 01
is set as SBU
or Solar first.
Battery voltage < Setting value
in Program 20
Open
Battery voltage>Setting value in
Program 21 or battery charging
reaches floating stage
Close
Operation and Display Panel
The operation and display panel, shown in below chart, is on the front panel of the inverter. It includes
three indicators, four function keys and a LCD display, indicating the operating status and input/output
power information.
LED Indicator
LED Indicator
Messages
AC/INV
Green
Solid On Output is powered by grid in Line mode.
Flashing Output is powered by battery or PV in battery mode
CHG
Yellow
Flashing
Battery is charging or discharging.
FAULT
Red
Solid On Fault occurs in the inverter.
Flashing Warning condition occurs in the inverter.
Function Keys
Function Key
Description
MENU
Enter or exit setting mode or go to previous selection.
UP
Increase the setting data.
DOWN
Decrease the setting data.
ENTER
Enter setting mode and Confirm the selection in setting mode or go to next
selection.