![PNI GreenHouse SC1800B Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/pni/greenhouse-sc1800b/greenhouse-sc1800b_user-manual_1569954012.webp)
User manual
12
En
gli
sh
Connecting photovoltaic modules
WARNING! Before connecting the PV modules, first install a DC circuit
breaker between the inverter and the photovoltaic modules.
WARNING! All connections must be made by qualified personnel only.
WARNING! For system safety and efficient operation, it is very important to
use the recommended type and size of cable.
Amperage
Gauge
Torque
60A
8 AWG
1.4~1.6Nm
Choosing the PV modules
Before choosing the PV modules, first consult the requirements below:
1. The open circuit voltage (Voc) of the PV modules (photovoltaic modules)
must not exceed the maximum open circuit voltage with the photovoltaic panel
of the inverter
2. The open circuit voltage (Voc) of the PV modules (photovoltaic modules)
must be higher than the minimum voltage of the battery.
Solar charging mode
MPPT charger
Inverter
3KW
Charging current
60A
The maximum open circuit voltage of the PV modules 145Vdc
PV panel voltage range
30~120Vdc
Minimum battery voltage for PV charging
17Vdc
System DC voltage
24Vdc
Follow the steps below to connect the PV modules:
1. Remove the 10 mm protection from the positive and negative conductors.
2. Check the connection polarity of the PV module cables and the PV input
connectors. Then, connect the positive pole (+) of the connection cable to
Содержание GreenHouse SC1800B
Страница 1: ...PNI GreenHouse SC1800B Solar inverter Invertor solar EN User manual 3 RO Manual de utilizare 39...
Страница 2: ......
Страница 7: ...7 User manual English Install the inverter by fixing two screws in the upper part...
Страница 43: ...Manual de utilizare Romana 43 Instalati invertorul fixand doua suruburi in partea superioara...
Страница 75: ......
Страница 76: ......