5.
SECURE DRAIN LINES
Fasten drain lines from prefilter/separator to floor or
drain. Pressurized air will periodically pass through
drain lines, which will cause an unsecured line to
whip and may cause bodily injury.
WARNING
Air from compressor and from air drying system, as
equipped, is not safe for human respiration
(breathing).
To provide safe, breathable air, compressor must be
capable of producing at least Grade D breathing air as
described in Compressed Gas Association Commodity
Specification G7.1-1966. Special filtering, purifying and
associated alarm equipment must be used to convert
compressed air to “Breathing Air.” Other special
precautions must also be taken.
Refer to OSHA 29 CFR 1910.134.
DISCLAIMER OF WARRANTY
If this unit is used to produce breathing air, the special
equipment and precautions expressed in OSHA 29 CFR
1910.134 for specifications of the necessary equipment
and special precautions to make Breathing Air MUST BE
used or any warranties are VOID and manufacturer
disclaims any liability whatsoever for loss, personal
injury or damage.
CAUTION
Connect oil coalescing prefilter with automatic drain
before the dryer to prevent any oil or slugs of water
carryover into the desiccant. Connect particulate
afterfilter downstream of the dryer to retain any
desiccant dust flowing into the process air lines.
Содержание EH Series
Страница 1: ...Heatless Regenerative Air Dryers PHM Series PH Series EH Series Owner s Manual 9829 2103 75 May 2009 ...
Страница 8: ...INSTALLATION OPERATION FIGURE 1 COMPRESSED AIR SYSTEM RECOMMENDED INSTALLATION FLOW DIAGRAM 7 ...
Страница 13: ...FIGURE 3 PH EH SERIES HEATLESS AIR DRYER FLOW DIAGRAM 12 ...
Страница 17: ...FIGURE 4 PHM MINI SERIES HEATLESS AIR DRYER FLOW DIAGRAM 16 ...
Страница 19: ...AL2 AL N L Power mA Output SENSOR BLUE GREEN RED FIGURE 6 DEWPOINT DEMAND DPD OPTION WIRING 18 ...
Страница 24: ...Pneumatech 4909 70th Avenue Kenosha WI 53144 Phone 262 658 4300 Fax 262 658 1945 www pneumatech com ...