background image

 
The Eagle 120 Recorder contains a lithium battery. This battery is not user replaceable.  
Follow all applicable regulations concerning disposal of batteries if the Eagle 120 
Recorder is discarded, or return the unit to the factory for disposal. 
 
Although the Eagle 120 Recorder Voltage has been designed and built to be as safe as 
possible, great care should be exercised at all times during operation and installation. The 
National Electric Code should be followed at all times. 
 
The Eagle 120 convenience receptacle is rated at 15 amps, for use with a 15 amp branch 
circuit. As per the National Electric Code, the maximum allowable load on this receptacle 
is 12 amps. When the Eagle 120 is plugged into a 120VAC receptacle, this voltage is 
present on the convenience outlet. Use the same caution with this convenience outlet as 
with any 120VAC source. 
 
Do not use this outlet where normal breaker operation could cause a loss of power to life-
critical equipment or cause a dangerous situation to exist. 
 
A three-wire to two-wire isolation adapter may be used with the VP-2 to plug the Eagle 
120 into a two-wire receptacle with no earth ground. If this is done, the ground on the 
convenience receptacle is not connected to earth ground. Do not plug devices which 
require an earth ground into the convenience receptacle if this grounding scheme has 
been defeated. 
 
The Eagle 120 is not designed for use with medical equipment or situations where life-
critical equipment is being used. The convenience outlet in the Eagle 120 is not a hospital 
grade receptacle. 
 
Do not use near heat sources such as radiators and electric heaters.  
 
 
 

3 Getting Started with the Eagle 120 Recorder 

The Eagle 120 Recorder is an electronic recording device which plugs into a standard 15 
amp receptacle. The unit measures and records voltages from line to neutral and neutral 
to ground. The Eagle 120 Recorder powers itself from the 120V line. After data has been 
recorded, the unit is connected to a PC with a USB cable. ProVision, the PC data analysis 
software, is used to extract the data from the Eagle 120 Recorder. With ProVision, data 
may be graphed, turned into reports, and exported to spreadsheets. 

 

3.1 Contents of the Eagle 120 Recorder Package 

The Eagle 120 Recorder is packaged with the following items: 

•  

The Eagle 120 Recorder 

•  

CD-ROM containing ProVision and all documentation 

•  

USB communications cable 


If any of these items are missing, please call PMI immediately. The CDROM includes the 
latest version of ProVision, example data files, and documentation for ProVision and all 

Содержание Eagle 120

Страница 1: ...Eagle 120 Recorder User s Manual Power Monitors Inc June 6 2006...

Страница 2: ...n the established Voltage Recorder line the Eagle 120 Recorder provides a voltage measurement processing and reporting system with a proven performance history In summary the Eagle 120 Recorder Voltag...

Страница 3: ...nvenience receptacle is not connected to earth ground Do not plug devices which require an earth ground into the convenience receptacle if this grounding scheme has been defeated The Eagle 120 is not...

Страница 4: ...ountdown After the countdown the Eagle 120 Recorder starts recording Later after the desired data is recorded the data from the Eagle 120 Recorder is downloaded into ProVision ProVision is then used t...

Страница 5: ...ed data it is downloaded into ProVision or a Palm PDA The Eagle 120 Recorder may be downloaded in the field by connecting the USB cable into a laptop see PC Communications with the eagle 120 Recorder...

Страница 6: ...gle 120 Recorder The green LED lights up steadily in this mode to indicate that it is in communications mode and ready for communications In ProVision the recorder serial number will appear within 2 m...

Страница 7: ...Date Time allows the user to synchronize the recorder with the PDA Tap Set Time to change the Date Time of the PDA 10 4 USING THE Eagle 120 RECORDER 4 Initialize allows the user to set parameters and...

Страница 8: ...vice Real power watts reactive power vars apparent power volt amps and power factor are computed for each leg These are computed using the voltages from line to neutral and current through each leg Th...

Страница 9: ...depends on good thresholds and settings A threshold that is too tight will cause the Recorder to log records that aren t really worth analyzing These extraneous records often hide the hopefully few im...

Страница 10: ...at our option of the defective unit or its components PMI is not responsible for products which have been subject to misuse alteration accident or for repairs not performed by PMI The foregoing warran...

Страница 11: ...Harrisonburg VA 22802 Attn Repair Dept...

Отзывы: