background image

power factor measurement, there is no disadvantage. These record types include graphs, 
Daily Profiles, Histograms, and Energy Usage. 
 

5.1.3 Using the Recorder 

The PMI Recorder can record every available record type simultaneously. Each record 
type has its own fixed memory allocation, so there is no danger of one errant record type 
filling the Recorder memory to the exclusion of other record types (for example, Event 
Capture can never overflow into graph memory). Thus the choice usually isn’t what to 
record types to record, but what record types to examine. In order to answer that question, 
a good understanding of each record type is required. The details of each record type, and 
potential uses, are described in the ProVision manual. 
 
 

6 Warranty Clause 

Power Monitors Inc. (PMI) warrants each new product manufactured and sold to be free 
from defects in material, workmanship, and construction, and that when used in 
accordance with this manual will perform to applicable specifications for a period of one 
year after shipment. 
 
If examination by PMI discloses that the product has been defective, then our obligation 
is limited to repair or replacement, at our option of the defective unit or its components. 
PMI is not responsible for products which have been subject to misuse, alteration, 
accident, or for repairs not performed by PMI. 
 
The foregoing warranty constitutes PMI’s sole liability, and is in lieu of any other 
warranty of merchantability or fitness. PMI shall not be responsible for any incidental or 
consequential damages arising from any breach of warranty. 
 
Equipment Return 
If any PMI product requires repair or is defective, call PMI at (800) 296- 4120 before 
shipping the unit to PMI. If the problem cannot be resolved over the phone, PMI will 
issue a return authorization number. For prompt service, all shipments to PMI must 
include: 
 
1. Billing and shipping address for return of equipment. 
2. The name and telephone number of whom to contact for further information. 
3. A description of the problem or work required. 
4. A list of the enclosed items and USB numbers. 
5. A return authorization number. 
6. If possible, a copy of the original invoice. 
 
Equipment returned to PMI must be shipped with freight charges prepaid.  After repair, 
PMI will return equipment F.O.B. factory. If equipment is repaired under warranty 
obligation, freight charges (excluding air freight or premium services) will be refunded or 
credited to the customer’s account. 

Return equipment to: 
Power Monitors, Inc. 
1661 Virginia Avenue 

Содержание Eagle 120

Страница 1: ...Eagle 120 Recorder User s Manual Power Monitors Inc June 6 2006...

Страница 2: ...n the established Voltage Recorder line the Eagle 120 Recorder provides a voltage measurement processing and reporting system with a proven performance history In summary the Eagle 120 Recorder Voltag...

Страница 3: ...nvenience receptacle is not connected to earth ground Do not plug devices which require an earth ground into the convenience receptacle if this grounding scheme has been defeated The Eagle 120 is not...

Страница 4: ...ountdown After the countdown the Eagle 120 Recorder starts recording Later after the desired data is recorded the data from the Eagle 120 Recorder is downloaded into ProVision ProVision is then used t...

Страница 5: ...ed data it is downloaded into ProVision or a Palm PDA The Eagle 120 Recorder may be downloaded in the field by connecting the USB cable into a laptop see PC Communications with the eagle 120 Recorder...

Страница 6: ...gle 120 Recorder The green LED lights up steadily in this mode to indicate that it is in communications mode and ready for communications In ProVision the recorder serial number will appear within 2 m...

Страница 7: ...Date Time allows the user to synchronize the recorder with the PDA Tap Set Time to change the Date Time of the PDA 10 4 USING THE Eagle 120 RECORDER 4 Initialize allows the user to set parameters and...

Страница 8: ...vice Real power watts reactive power vars apparent power volt amps and power factor are computed for each leg These are computed using the voltages from line to neutral and current through each leg Th...

Страница 9: ...depends on good thresholds and settings A threshold that is too tight will cause the Recorder to log records that aren t really worth analyzing These extraneous records often hide the hopefully few im...

Страница 10: ...at our option of the defective unit or its components PMI is not responsible for products which have been subject to misuse alteration accident or for repairs not performed by PMI The foregoing warran...

Страница 11: ...Harrisonburg VA 22802 Attn Repair Dept...

Отзывы: