TROUBLESHOOTING 

 
PROBLEM 

Hose  does  not  heat  and  the  display  on  the  controller  shows  a  flashing  error  message: 
“EEEE”  on  the  Auber  controller,  “SbEr”  on  the  Eaton  controller,  or  “S.ERR”  on  the  Omron 
controller. 

 

SOLUTIONS 

1.  Check  the  thermocouple  terminals  (TC+  and  TC-)  on  the  heater  controller  for  loose 

wires and improper connections.  There should be a purple wire connected to the TC+ 
Terminal  and  a  red  wire  connected  to  the  TC-  Terminal.    See  Table  1  below  for 
terminal connections for each type of controller. 

Table 1: Heater Controller Terminals and Thermocouple Wire Connections 

 

AUBER 

EATON 

OMRON 

TC+ Terminal (Purple Wire) 

Terminal 7 

Terminal 9 

Terminal 12 

TC- Terminal (Red Wire) 

Terminal 6 

Terminal 10 

Terminal 11 

If connections are secure, move to the next step.

 

2.  Remove  the  transformer  cover  and  ensure  the  thermocouple  wires  are  secure  to  the 

harness going up to the controller. 

If connections are secure, move to the next step. 

3.  Disconnect the wire from the TSU and connect it directly to the thermocouple harness 

coming out of the hose transformer. 

If the controller still shows the error code, replace the hose thermocouple. 

 

 

If  the  error  code  goes  away  and  temperature  is  now  shown  on  the  display  of  the 
controller,  then  all  the  TSU  harnesses  from  the  TSU  to  the  transformer  need  to  be 
checked for loose connectors or one or more of the harnesses are defective.

 

 

Содержание EL-51A

Страница 1: ...Phone 732 415 4400 Fax 732 364 4025 URL http www polymacusa com Before using the TSU carefully read all the technical and safety documentation included in this manual Pay special attention to the inf...

Страница 2: ...i EL 51A 4 TABLE OF CONTENTS TABLE OF CONTENTS WARRANTY 1 SAFETY AND HANDLING 3 CHARACTERISTICS 5 TECHNICAL SPECIFICATIONS 5 DESCRIPTION 6 INSTALLATION 7 TROUBLESHOOTING 8 PARTS IDENTIFICATION 10 MANU...

Страница 3: ...rial number The Warranty does not cover any Product if the Original Invoice appears to have been modified or altered or when the serial number on the Product appears to have been altered or defaced Pr...

Страница 4: ...y for Products Repaired or Replaced under Warranty Following the repair or replacement of a Product covered by this Warranty such Product will continue to be subject to the original Warranty for the r...

Страница 5: ...TION Presents information that indicates how to avoid damage to the Proportioner or how to avoid a situation that could cause minor injuries NOTE Is relevant information of a procedure being carried o...

Страница 6: ...t possible injury caused by incorrect handling of the raw materials and solvents used in the process carefully read the Safety Data Sheet SDS provided by your supplier Deal with the waste caused accor...

Страница 7: ...HARACTERISTICS Accurate and precise Compact design Easy to install Low maintenance TECHNICAL SPECIFICATIONS Thermocouple Type Type E Temperature Range 0 to 1000 o F 18 to 540 o C A Side Fittings 5 JIC...

Страница 8: ...RIPTION DESCRIPTION A Thermocouple Connector B Flexible Metal Conduit C A Side Inlet Fitting D A Side Outlet Fitting E Sensing Wire F R Side Inlet Fitting G TSU Body H R Side Outlet Fitting I Air Inle...

Страница 9: ...ly bend the Heated Hoses Do not coil the Heated Hoses with a diameter of less than 4 feet 1 22 meters Recommended order of connections 1 It is recommended that the TSU be installed between the last se...

Страница 10: ...ding to current regulations To avoid damage caused by the impact of pressurized fluids do not open any connection or perform maintenance work on components subject to pressure until the pressure has b...

Страница 11: ...tions AUBER EATON OMRON TC Terminal Purple Wire Terminal 7 Terminal 9 Terminal 12 TC Terminal Red Wire Terminal 6 Terminal 10 Terminal 11 If connections are secure move to the next step 2 Remove the t...

Страница 12: ...2 1 EL 00051A 3 1 8 X 4 JIC FEM SWIVEL FTG 3 1 EL 00051A 4 1 4 X 5 JIC MALE FTG 4 1 EL 00051A 5 1 4 X 6 JIC FEMALE SWIVEL FTG 5 1 EL 00051A 6 1 4 X 6 JIC MALE FTG 6 1 EL 00051A 7 1 4 X 5 JIC FEMALE S...

Страница 13: ...Revision Date Changes Approved 1 0 09 01 2015 Initial release of EL 51A 4 Manual Vadams 1 1 09 15 2017 Change position of the page number from bottom center to bottom right SS 1 2 04 02 2019 Updated...

Отзывы: