000115682/151018/0 WallPro 

EN - 7

WallPro “UL” types

11

 (60Hz versions) only

 

- Components necessary for electrical installation according to 

UL and federal, state or local wiring regulations

Option

In case of a dustbin extension set:

 

- duct Ø 200 mm or 8 in. 

4.2 

Unpacking

Make sure that the product is complete. The package contains: 

Filter unit

 

- Filter unit (without side panels), incl. 10 m cable

12

 

 

- Wall bracket 

 

- Dustbin set

 

- Air hose (filter pressure) 2x10 m 

 

- SealApplicator (seal assembly lubricant) 

 

- Filter disposal bag (5 pieces)

 

- Mounting material

Side panel (2)

 

- Side panel

Mounting kit

 

- Mounting and ducting material (types “DM” only)

 

- Inlet  non-return valve

Additionally for “EM” configurations in 60Hz:

•  Duct adapter metric-imperial

13

  

(WallPro Single: 1 piece | WallPro Double: 2 pieces) 

For an overview of the mounting material per 

specific configuration, refer to Fig. IV on page 22.

Extraction arm (1 or 2)

Refer to the installation manual of the KUA-160 or KUA-200, 

that is supplied with the product. 

Extraction fan

 

- Fan

 

- Fan outlet transition (from rectangular to round Ø 250 mm)

Control equipment

 

- Control box

4.3 

Stationary filter unit

ATTENTION

It is important to follow the mounting sequence as 

written in this (4.3) and the next (4.4) chapter. 

The table below explains the various configuration types. 

WallPro type

Explanation

Single-

1 extraction arm

Double-

2 extraction arms

Basic

no extraction arm(s)

160/

Arm diameter Ø 160 mm

200/

Arm diameter Ø 200 mm

3-

Arm length 3 m

4-

Arm length 4 m

DM

Direct mount

EM

External mount

11.  The “UL” certification applies to the control box
12.  For connection with the control box
13.  From Ø 160 to Ø 6 in. / Ø 200 to Ø 8 in., depending on the configuration

CE

Control box: CE marking

UL

Control box: UL certified

A number of installation steps are only applicable to one or 

more specific configurations. These are indicated at the 

beginning of a certain paragraph. The grey/empty cells are 

universal. 

Some examples:

In case of:

Applies to all 

“DM” types

DM

In case of: 

Applies to all 

WallPro Single 

types and all 

“EM” types 

WallPro Single-

EM

Write your configuration type below. 

WallPro type

TIP

For stable assembly conditions, we recommend to 

leave the filter unit on the pallet (until step 4.6). 

4.3.1  Reinforcement plate

In case of: 

DM

In case of a WallPro Single “DM” (direct mount) you must 

install a reinforcement plate behind the lower part of the side 

panel to carry the weight of the arm b extraction arm. 

The package of the WallPro Double “DM” contains two 

reinforcement plates for both sides of the filter housing. 

In case of a WallPro type “EM” (external mount), 

where the extraction arm is mounted separately 

from the filter unit, the reinforcement plate is not 

necessary. In that case, proceed with par. 4.3.2.

To install the reinforcement plate, do the following. 

Fig. 4.2

•  Insert the 4 cage nuts M12 from the inside in the 

corresponding positions of the plate; 

 

- KUA-160 / arm Ø 160 mm: inner positions (A)

 

- KUA-200 / arm Ø 200 mm: outer positions (B)

Fig. 4.2 

A

B

Cage nuts

Содержание WALLPRO

Страница 1: ...www plymovent com EN Stationary filter unit EN Installation and user manual WALLPRO...

Страница 2: ...of this document This publication is to be used for the standard model of the product of the type given on the cover page Thus the manufacturer cannot be held responsible for any damage resulting fro...

Страница 3: ...e 3 1 Introduction 3 2 Product description 4 3 Safety instructions 5 4 Installation 6 5 Use 14 6 Maintenance 15 7 Troubleshooting 17 8 Spare parts 18 9 Electrical diagram 18 10 Disposal 18 CE declarat...

Страница 4: ...product name serial number You can find these data on the identification plate 1 INTRODUCTION 1 1 Identification of the product The identification plate contains among other things the following data...

Страница 5: ...A 160 2x KUA 200 n a n a 2 x 1000 m h 2 x 1450 m h WallPro Basic 1 inlet left or right 2 inlets left and right 1250 m h n a 2100 m h 2 x 1550 m h 1 For fan type FUA 3000 2 For fan type FUA 4700 Silenc...

Страница 6: ...ations User manual Everyone working on or with the product must be familiar with the contents of this manual and must strictly observe the instructions therein The management should instruct the perso...

Страница 7: ...icient approved fire extinguishers suitable for fire classes ABC Do not leave any tools or other objects in or on the unit The welding current return circuit between the workpiece and the welding mach...

Страница 8: ...m s 160 Arm diameter 160 mm 200 Arm diameter 200 mm 3 Arm length 3 m 4 Arm length 4 m DM Direct mount EM External mount 11 The UL certification applies to the control box 12 For connection with the co...

Страница 9: ...embly Make sure that the non return valve can fully open In case of a LL 5 5 24 Manual on off switch on the hood incl LED working light option Install the cable gland M16 nut M16 C If not Install the...

Страница 10: ...3 3 Fig 4 6 Mounting of the arm bracket In case of WallPro Double DM If applicable Do the same procedure for the other arm bracket In case of EM Recommended installation height of the arm bracket at...

Страница 11: ...s coupling Connect the air hoses22 in the connectors and B C 21 You do not need these four bolts anymore The other two bolts remain unused but must stay in the inlet flange 22 The different colours si...

Страница 12: ...emove the blind plug C from the nearest left or right 24 cable gland B just below the indicator panel Feed the cable through the cable gland B inside the unit Tighten the cable gland 24 In case of a W...

Страница 13: ...gurations with an imperial duct size 6 in or 8 in 28 160 mm 6 in or 200 mm 8 in depending on the inlet diameter 4 8 1 Dustbin extension set option For easy maintenance you can install the dustbin on t...

Страница 14: ...e Power Thermal relay Range Setting Single FUA 3000 230 V 2 HP 4 0 6 3 A 5 2 A 460 V 2 HP 2 2 3 2 A 2 4 A 575 V 2 HP 1 7 2 4 A 2 1 A PowerPlus FUA 4700 230 V 3 HP 7 5 10 5 A 8 8 A Double 460 V 3 HP 4...

Страница 15: ...paragraph 1 3 Fig 4 23 A B Fan outlet transition 4 11 Commissioning checklist Check Ref par OK 1 Are all cables correctly installed 4 9 1 2 Are the air hoses and correctly installed 4 9 1 3 Is the dir...

Страница 16: ...filter cartridge refer to paragraph 6 2 To prevent unnecessary filter replacement make sure that compressed air is available and connected the pressure setting is correct refer to paragraph 4 9 2 5 3...

Страница 17: ...replace the filter cartridge Personal protective equipment PPE Wear respiratory protection and protective gloves when you replace the filter cartridge WARNING Do not replace the filter cartridge whil...

Страница 18: ...The washer is supplied with the new filter cartridge 34 The star knob is attached to a rope to prevent loss Turn the rotary knob A in vertical position to open the shut off valve If applicable energi...

Страница 19: ...ue button Dust leakage from the hopper Sealing is insufficient The adhesive rubber strip is damaged or worn Replace the adhesive rubber strip The star knobs of the hopper are not fully tightended Full...

Страница 20: ...ibility that the product WallPro which this declaration refers to is in accordance with the conditions of the following Directives Machine Directive 2006 42 EC EMC 2014 30 EU LVD 2014 35 EU ErP Direct...

Страница 21: ...Dimens es FR Dimensions PL Wymiary A B C E D F G H WallPro mm inch A 700 27 6 B Single 1991 78 4 Basic Single PowerPlus 2059 81 1 Basic PowerPlus Double C 1236 48 7 D 975 38 4 E 764 30 1 F 123 4 8 G K...

Страница 22: ...orking range Max distance Max angle Mounting position E Wall mounting F On a stanchion or similar NL Werkbereik Max afstand Max hoek E Wandmontage F DE Bereich E F FR Port e E F ES Alcance de trabajo...

Страница 23: ...SET 5 SET 5 SET 5 SET 5 SET 1 Wall bracket 2x Bolt M10x30 2x Locknut M10 4x Washer M10 SET 2 Side panel 1x Screw plug M16 1x Nut M16 1x Cable gland M16 24x Bolt M6x16 24x Sealing washer M6 SET 3 Reinf...

Страница 24: ...d e d installation E configuration des trous ES Altura de instalaci n recomendada E dise o de agujeros IT Altezza di installazione raccommandata E disposizione dei fori PT PL Zalecana wysoko monta u E...

Страница 25: ...83 0040900010 0000117119 0000118185 0000117120 0000117546 0000117872 0000117875 0000117871 0000117900 0000118194 EN Exploded view filter unit WallPro NL Exploded view filterunit WallPro DE Explosionsz...

Страница 26: ...alve 160 mm NRV 160 Terugslagklep 160 mm NRV 160 R ckschlagklappe 160 mm WallPro FR Pi ces d tach es ES Piezas de recambio IT Pezzi di ricambio 0000100306 FUA 3000 IEC 400V 3ph 50Hz FUA 3000 IEC 400V...

Страница 27: ...Exploded view control box 0000102289 0000117869 0000117868 CE 0000118192 UL 0000101413 CE UL 0000102287 0000102288 0000117133 0000117134 0040900200 0000117870 0000117120 0000117873 0000117874 00001179...

Страница 28: ...mbar sticker schaal 60Hz Differenzdruckschalter 6 50 mbar Aufkleber Skala 60Hz 0040900200 Thermal relay NTR 4 0 6 3 A Thermisch relais NTR 4 0 6 3 A Thermisches Relai NTR 4 0 6 3 A Control box FR Pi c...

Страница 29: ...www plymovent com 000115682 151018 0 WallPro...

Отзывы: