000115682/151018/0 WallPro
EN - 9
Fig. 4.5
<60 s
4x
24x
1
3
2
5
4 6
Mounting of the side panel
In case of:
WallPro Double-
DM
• Repeat the instructions of paragraph 4.3.3 to install the
other side panel.
In case of:
WallPro Single-
WallPro Basic
EM
• Repeat the instructions of paragraph 4.3.3 to install the
side panel
19
, with the exception of steps (4) and (6). To
align the panel, put two bolts M6x16 in the top corners
first. Then install the remaining 22 bolts.
4.3.4 Arm bracket
In case of:
DM
ATTENTION!
Make sure that you have installed the reinforcement
plate behind the side panel; refer to paragraph
• Install the arm bracket on the filter unit with 4 bolts
M12x30
20
and washers M12.
19. WallPro Single: blind side panel | WallPro “EM”: side panel with inlet
non-return valve
20. The ones you used to align the side panel in step 4.3.3
Fig. 4.6 Mounting of the arm bracket
In case of:
WallPro Double-
DM
If applicable:
• Do the same procedure for the other arm bracket.
In case of:
EM
Recommended installation height of the arm bracket: at
approx. 2-2,3 m (6.5-7.5 ft) from the floor (top of the wall
bracket). Also refer to the footnote on page 10.
• Install the arm bracket(s) at the desired position on the
wall, preferably as close as possible to the filter unit.
4.4
Extraction fan
Depending on the selected configuration, the package contains
a fan type FUA-3000 or FUA-4700. You can install the fan in
different positions to get the desired outlet direction;
- FUA-3000: 6 possible directions
- FUA-4700: 2 possible directions (left and right)
Refer to Fig. III on page 21 for an overview of the
possible outlet directions.
To install the fan, do the following.
• Put adhesive rubber strip (A) around the inlet opening on
top of the filter unit. Make sure that the strip does not
entirely cover the holes.
• Disassemble the service panel (refer to Fig. 2.1F).
Fig. 4.7
A
Adhesive rubber strip