000115682/151018/0 WallPro
EN - 6
- During installation, always use Personal Protective
Equipment (PPE) to avoid injury. This also applies to persons
who enter the work area during installation.
- Use sufficient climbing gear and safety guards when working
on a higher level than 2 metres (local restrictions may
apply).
- Do not install the product in front of entrances and exits
which must be used for emergency services.
- Mind any gas and water pipes and electric cables.
- Make sure that the workspace is well illuminated.
- Stay alert and keep your attention to your work. Do not
install the product when you are under the influence of
drugs, alcohol or medicine.
- Air containing particles such as chromium, nickel, beryllium,
cadmium, lead etc., should never be recycled. This air must
always be brought outside the working area.
Use
WARNING!
Fire hazard! Do not use the product for:
- polishing applications in combination with
grinding, welding or any other application that
generate sparks
(fibers from polishing or abrasive flap disks
are highly flammable and pose a high risk of filter fires when
exposed to sparks)
- arc-air gouging
- extracting and/or filtering flammable, glowing or
burning particles or solids or liquids
- extracting and/or filtering of aggressive fumes
(such as hydrochloric acid) or sharp particles
- extracting and/or filtering dust particles which are
released when welding surfaces treated with
primer
- sucking cigarettes, cigars, oiled tissues, and other
burning particles, objects, and acids
WARNING!
Explosion hazard! Do not use the product for
explosion-hazardous applications, e.g.:
- aluminium laser cutting
- grinding aluminium and magnesium
- explosive environments or explosive substances/
gases
WARNING!
Do not use the product for:
- extraction of hot gases (more than 70°C/158°F
continuously)
- flame spraying
- oil mist
- heavy oil mist in welding fume
- extraction of cement, saw dust, wood dust etc.
- Inspect the product and check it for damage. Verify the
functioning of the safety features.
- During use, always use Personal Protective Equipment (PPE)
to avoid injury. This also applies for persons who enter the
work area.
- Check the working environment. Do not allow unauthorised
persons to enter the working environment.
- Protect the product against water and humidity.
- Make sure the room is always sufficiently ventilated; this
applies especially to confined spaces.
- Make sure that the workshop, in the vicinity of the product,
contains sufficient approved fire extinguishers (suitable for
fire classes ABC).
- Do not leave any tools or other objects in or on the unit.
- The welding current return circuit between the workpiece
and the welding machine has a low resistance. Thus avoid
connection between the workpiece and the WallPro, so that
there is no possibility of the welding current flowing back to
the welding machine via the protective earth conductor of
the WallPro.
Service, maintenance and repairs
- Obey the maintenance intervals given in this manual.
Overdue maintenance can lead to high costs for repair and
revisions and can render the guarantee null and void.
- Always use Personal Protective Equipment (PPE) to avoid
injury. This also applies for persons who enter the work area.
- Make sure the room is sufficiently ventilated.
- Use tools, materials, lubricants and service techniques which
have been approved by the manufacturer. Never use worn
tools and do not leave any tools in or on the product.
- Use sufficient climbing gear and safety guards when working
on a higher level than 2 metres (local restrictions may
apply).
- Clean the area afterwards.
ATTENTION
Service, maintenance and repairs must be
performed in accordance with directive TRGS 560
and TRGS 528 by authorised, qualified and trained
persons (skilled) using appropriate work practices.
ATTENTION
Before you carry out service, maintenance and/or
repair jobs:
- fully disconnect the unit from the mains
Personal protective equipment (PPE)
Wear respiratory protection and protective
gloves during service, maintenance and
repairs.
WARNING
The industrial vacuum cleaner that you use during
service and maintenance must meet dust class H
according to EN 60335-2-69 or HEPA class
(efficiency ≥99.97% at 0.3 µm).
4
INSTALLATION
4.1
Tools and requirements
You need the following tools and requirements to install the
unit:
- basic tools
- fork-lift truck
- electrical tools
4.1.1 To be sourced locally
General
- Wall mounting hardware for the filter unit
8
- Mains cable: 4G1.5
- type H05VV-F (PVC, standard cable); or:
- type H05RN-F (rubber, for heavy duty, e.g. when part of
the cable is on the floor)
- Motor cable: 4G1.5
- type H05VV-F (PVC, standard cable); or:
- type H05RN-F (rubber, for heavy duty, e.g. when part of
the cable is on the floor)
- Quick disconnect coupling with a male G 3/8” thread
- Compressed air hose
WallPro type “EM” only
- Wall mounting hardware for the arm bracket(s)
9
- Ducting Ø 160 mm (6 in.) / Ø 200 mm (8 in.)
10
between the
filter unit and the arm bracket(s)
8. The type of hardware depends on the wall type
9. For mounting at an external position; the type of hardware depends on the
wall type
10. Depending on the type of extraction arm