![Plymovent VSRX Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/plymovent/vsrx/vsrx_user-manual_1569261012.webp)
Plan View
3
2.1
2.2
1
MAN_MAG_VSRX_290518_LETTER_EN
Page 12 of 24
WARNING
PRODUCT MAY CONTAIN SHARP EDGES
Use care when servicing unit.
Failure to do so could result in minor personal injury.
4.3
Drive-Through Measurements
Please determine the position of:
1. Tailpipe
2.1
Entrance door.
2.2
Exit door.
3.
Distance between Entrance door / Exit door.
a. Determine the location of the exhaust pipe (1) on the vehicle:
- Which side of the vehicle is the tailpipe positioned?
- Where does the exhaust exit the vehicle?
- What is the diameter of the tailpipe?
Check if exhaust pipe modification is necessary, see “Modify
the Tailpipe” in this manual.
b. Measure the height and width of the garage (2.1 and 2.2).
Check the type of bay door:
- Rollup door
- Segmented panel overhead door (four-fold doors)
- Other type
Check at what height the rail can be installed. The height
should be in line with the specifications indicated in this
manual in order to ensure correct product performance.
c. Measure the distance between the entrance door and exit
door minus two (2x) times the distance between the end of
the rail and the exit door (3) distance shown in the Installation
Table on page 10.
The distance from the end of the rail to the door(s) must fall
in the distrance shown in the Installation Table on page 10.
CAUTION
Be sure to order the right Grabber dimension. If a
incorrect version is used on the tailpipe, the system
could be damaged or will not properly remove
exhaust from the facility.
Содержание VSRX
Страница 24: ...www plymovent com 050718 VSRX...