Plymovent SDCA Скачать руководство пользователя страница 6

0000118225/171018/A SDCA 

EN - 5

Fig. 4.2b   Positioning the hose connections in the sleeve

USE

The SDCA connects the lower hose to the upper hose 

assembly. In the unlikely event the nozzle remains engaged as 

the vehicle exits the facility, the unit disconnects from the 

assembly to prevent damage to the system. 

CAUTION!

Do not hang or swing on the hose as you will 

damage the exhaust removal system. 

CAUTION!

Do not drive out of the service bay with the nozzle 

still connected to the vehicle. 

CAUTION!

In case of using the SDCA in combination with a 

hose reel, make sure the hose reel is installed 

correctly. When in doubt, please contact Plymovent.

For more information please consult the hose reel 

manual.

TROUBLESHOOTING

Problem

Possible cause

Solution

The SDCA releases 

too quick

Spring tension too 

low

Increase spring 

tension by turning 

the adjustment 

screws clockwise. 

Refer to fig. 4.2a.

The SDCA does 

not release

Spring tension too 

high

Increase spring 

tension by turning 

the adjustment 

screws counter 

clockwise. Refer to 

fig. 4.2a.

DISPOSAL 

After life of the product, dispose it of in accordance with

federal, state or local regulations.

SPARE PARTS

There are currently no spare parts available for this product.

CE DECLARATION

We, Plymovent, Koraalstraat 9, 1812 RK Alkmaar, the

Netherlands, herewith declare, on our own responsibility, that

the product(s):

-  SDCA

which this declaration refers to, is/are in accordance with the

conditions of the following Directive:

and is/are in conformity with the following harmonized

standard(s) and/or other such normative doc

amendments, if any:

Alkmaar, the Netherlands, October 17

th

, 2018

Kees Janssen

Product Manager EE

A

B

Отзывы: