MultiSmart

®

Arm/ENG/USA/CAN/6/16

Energy Saver

For automatic start/stop of fan. Adjustable overrun
period of between 7 sec. to 6 min. Incl. inductive sensor
with 5 m, (16 ft) cable. Built-in contactor
must be fitted with relevant fan-motor overload
 (not included). Power supply: 3~¨230/400 V*.

Prod. no ES-90-005

 incl. 75 VA/24 V

transformer for hood light.

Prod. no ES-90-006

 incl. 75 VA/24 V

transformer. For two arms with lights.

Complementary products and accessories

Fan

Airflow
Freeblowing
m

3

/h, 

CFM

Motor
kW V
(50Hz)

1300, 765

1300, 765

1800, 1059

2100, 1236

2100, 1236

3000, 1766

4700, 2766

6000, 3532

1300

1301

1800

2100

2101

3000

4700

6000

0,37 kW 3~ 400 V*

0,37 kW 1~ 230 V*

0,55 kW 3~ 400 V*

0,75 kW 3~ 400 V*

0,75 kW 1~ 230 V*

1,10 kW 3~ 400 V*

2,20 kW 3~ 400 V*

4,00 kW  3~400 V*

S t a n c h i o n

Accessory for ceiling, floor or wall mounting
of MultiSmart

®

 Arm.

Length: 110 cm, 3.6 ft. 

Prod. no PA-110

Length: 220 cm, 7.2 ft.

 Prod. no PA-220

SmartArm Extention kit

Contains all neccesseary items to convert a 3
meter, (10 ft) arm to a 4 meter, (14 ft) arm.

Prod. no SAE-125-4
Prod. no SAE-160-4
Prod. no SAE-200-4

Transformer

230 V* – 24V/75 VA transformer for
halogen lamp cartridge HL-20/24.

Prod. no TR-24/75

Fully automatic damper

Fully automatic motordriven damper for fitting
to Ø 160 mm, 6" Ø duct. Adjustable overrun
period between 7 sec. and 6 min., to
capture after-fume. Inductive sensor
 with 5 m (16 ft) of cable is included
as standard. Power supply: 1~ 230 V*.
Can be complemented with switch
assembly (S-100) for manual
control.

Prod. no ASE-12

Control unit

For automatic start/stop of a central fan in
a system with several extractors. To be used in
conjuction with the Energy Saver or Automatic
Damper. Power supply: 3~ 230/400 V*.

Prod. no M-1000

Fans FS and FA

Available in many sizes with free blowing air volumes
from 1300 m

3

/h, 765 CFM to 6000 m

3

/h,3532 CFM. A

unique anti-spark impeller made from aluminium gives
maximum security.

NOTE! ALL FANS MUST BE FITTED
WITH RELEVANT MOTOR OVERLOAD
PROTECTION (NOT INCLUDED).

Starter

For manual start/stop of the fan via a switch in
the hood. Complete with switch assembly and
10 m, (33 ft) cable. Built-in contactor must be fitted
with relevant fan motor overload (not included).
Power supply: 3~ 230/400 V*.

Prod. no SA-24/75 

incl. 75 VA/24 V

transformer for halogene lamp on one workstation.

Prod. no SA-24/75-2

 incl. 75 VA/24 V transformer

for two halogene lamps on two workstations.

Halogen lamp cartridge

To be fitted in the hood. Consists of 20W/
24 V halogen lap, switch assembly and
10 m, (33 ft) cable. Must be complemented
with transformer TR-24 or Starter SA-24.

Prod. no HL-20/24-125
Prod. no HL-20/24-160
Prod. no HL-20/24-200

Switch assembly

Switch assembly with 10 m(10 ft) cable for manual
operation from the hood of fan and light. Also
supplied as standard as part of ES-90 and ASE-12.
Inkl.

Prod. no S-100

Damper kit

Contains all necceseary items to
install a ratchet damper for fine
tuning the airflow through the arm.

Prod. no D-125
Prod. no D-160
Prod. no D-200

* Other voltages and frequences for motors are available.

* Other voltages are available

* Other voltages are available

* Other voltages are available

* Other voltages are available

* Other voltages are available

FS

* Is not available in MSAS

* Not available in MSAS

Содержание MULTISMART ARM MSA-125-3

Страница 1: ...s 2 Technical data 2 Design and function 3 Handling 3 Hoodoperation 3 Mounting example 3 Workingradius 3 Pressure loss 4 Alternative system layouts 5 Complementary products and accessories 6 Mounting...

Страница 2: ...ogram arm for which we have a patent application The construction allows a stepless positioning within the operating range The MultiSmart Arm has an extremely smooth movement The MultiSmart Arm reache...

Страница 3: ...with internal steel spiral E Aluminium inner arm tube F Adjusting mechanism for gas spring tension G A patent pending paralellogram arm with gas springs for perfect balance and easy movement H Alumini...

Страница 4: ...MultiSmart Arm MSA 125 3 4 100 0 4 300 1 2 500 2 0 700 2 8 900 3 6 1100 4 4 1300 5 2 300 177 400 235 500 293 600 353 700 412 800 470 m3 h CFM Airflow Pressure loss MultiSmart Arm MSA 160 3 4 100 0 4...

Страница 5: ...ntral system 3 x MultiSmart Arm with one fan FS 4700 Recommended fan per no of arms FS 3000 2 3 arms FS 4700 3 4 arms FA 6000 4 5 arms Recommendation for 160 mm for other diameters contact PlymoVent A...

Страница 6: ...ol unit For automatic start stop of a central fan in a system with several extractors To be used in conjuction with the Energy Saver or Automatic Damper Power supply 3 230 400 V Prod no M 1000 Fans FS...

Страница 7: ...Paralellogram chassie G Inner arm tube H Hose for connecting arm to ducting or fan I Wall bracket H D G F D E D D D C B A D Copyright All right reserved All information within this printed matter may...

Страница 8: ...make sure that the structure of the wall is strong enough 3 If you have purchased a MSA XXX 3 you can skip to step no 5 If you have purchased a MSA XXX 4 or a SAE XXX 4 please continue to following th...

Страница 9: ...can go to step no 11 8 Remove the stickers covering the mounting holes A for the damper and the hose between the hood and the outer tube B and mount the ratchet C to the top of the tube using the sup...

Страница 10: ...embly and light cartridge can be stuffed back into the switch assembly housing 12 Remove the mesh A from inside of the hood The most efficient way to do this is to grab the mesh with a set of pliers a...

Страница 11: ...page Also check that the wall bracket is level 2 Check and adjust the friction joints marked B on the figure The moment in the friction joints is right when the elastic washers below screw and nut ha...

Страница 12: ...l bracket and the attachment plates for the arm is correct when the three holes of sight fits exactly linedup centre with the banana formed hole in outer part of the wallmount This is very important f...

Страница 13: ...ormation within this printed matter may not be reproduced handed over copied xeroxed or translated into another language in any form or any means without written permission from PlymoVent AB PlymoVent...

Страница 14: ...No A B C D E F G Description Note 1 526 178 1 Inner tube 125 526 194 1 Inner tube 160 526 210 1 Inner tube 200 3 988 113 1 Hose vmp D 127 L 750 989 012 1 Hose vmp D 161 L 750 999 581 1 Hose vmp D 205...

Страница 15: ...x 4 Abreviations X Order as requiered state requiered length 15 526 400 1 Mesh 265 506 808 1 Mesh 300 526 459 1 Mesh 340 16 988 105 1 Hose VMP D 127 L 450 988 998 1 Hose VMP D 161 L 450 999 573 1 Hose...

Страница 16: ...be 160 3 998 310 X Hose food grade 127 L 750 998 427 1 Hose food grade 165 L 750 4 998 310 X X Hose food grade 127 L 1200 998 435 1 1 Hose food grade 165 L 1200 5 961 455 6 2 Hose clamp 127 961 540 6...

Отзывы: