background image

0000101015/100821/F MistEliminator 

7

Fig. 6.2 

A
B
C

A

B

C

Removal of the filters

TROUBLESHOOTING

If the system does not function (correctly), consult 

the checklist below to see if you can remedy the 

error yourself. Should this not be possible, contact 

your supplier.

Symptom

Problem

Possible 

cause

Solution

Oil leakage 

inside the 

filter module

Pollution of 

the filter 

housing

Filter(s) placed 

incorrectly

Install the filter(s) 

correctly and lock 

them

Sealing 

material of 

filter(s) is 

damaged or 

loose

Replace the filter(s)

SPARE PARTS

The following spare parts are available for the 

product.

8.1 

ME-31 / ME-32 (F1 / F2)

Refer to Fig. II on page 9.

8.2 

ME-41 / ME-42 (F1 / F2)

Refer to Fig. III on page 10

DISPOSAL

After the life of the product, dispose it of in 

accordance with federal, state or local regulations.

CE DECLARATION

CE declaration of conformity for machinery

We, Plymovent Manufacturing B.V., Koraalstraat 9, 

1812 RK Alkmaar, the Netherlands, herewith 

declare, on our own responsibility, that the products:

 

- ME-42/F1

 

- ME-42/F2

which this declaration refers to, are in accordance with the 

conditions of the following Directives:

 

- Machine Directive 2006/42 EC

and is/are in conformity with the following harmonized 

standard(s) and/or other such normative doc 

amendments, if any:

 

- EN ISO 12100-1 (safety of machinery)

 

- EN ISO 12100-2 (safety of machinery)

 

- EN ISO 13857 (safety distances)

Alkmaar, the Netherlands, 1st July 2019

M.K. Geus 

Product Manager

Содержание MistEliminator ME-31

Страница 1: ...www plymovent com Oil mist filter Installation and user manual MISTELIMINATOR EN...

Страница 2: ...tallation use maintenance and repair of the product mentioned on the cover page of this document This publication is to be used for the standard model of the product of the type given on the cover pag...

Страница 3: ...tEliminator is a stationary filter for mainly oil mist applications to be used in machine tool processes Depending on the specific application it is available with four different filter packages1 with...

Страница 4: ...pre filter to keep larger particles ME 31 3 Bag filter for main filtration ME 32 3 Bag filter for main filtration 4 HEPA filter for final filtration ME 41 3 OC 1 self draining filter cassette that coa...

Страница 5: ...model and the function of the technical product which is considered normal use Operating the machine within the limits of its intended use also involves observing the instructions in the user manual W...

Страница 6: ...and ME 42 F2 only If required necessary connect the fan outlet to an exhaust duct Other types without integrated fan Install an optional FUA series fan on the filter outlet or Connect the outlet to t...

Страница 7: ...e oil container To empty the oil container do the following Remove the oil container and close it by the supplied cap Empty the container and put it back in place When you empty the container prevent...

Страница 8: ...to Fig II on page 9 8 2 ME 41 ME 42 F1 F2 Refer to Fig III on page 10 9 DISPOSAL After the life of the product dispose it of in accordance with federal state or local regulations CE DECLARATION CE dec...

Страница 9: ...K L ME 31 ME 32 ME 31 ME 32 ME 41 ME 42 ME 41 ME 42 ME 42 F1 ME 42 F2 I B ME 31 J K L I ME 42 F1 ME 42 F2 D mm inch A 2037 80 2 B 1637 64 4 C 680 26 8 D 335 13 2 E 250 9 8 F 395 15 6 G 595 23 4 H 395...

Страница 10: ...re filter 0000101330 Lock with handle set of 2 0000101333 Cassette bag lock set of 2 0000101335 Lower door of bag filter module incl locks hinges and sticker 0000101336 Upper door of bag filter module...

Страница 11: ...0Hz 0000100823 Oil container 8 liters 0000100824 ME INL IMP HydroFilter impinger 0000100825 ME INL PF Pre filter 0000101330 Lock with handle set of 2 0000101333 Cassette bag lock set of 2 0000101339 D...

Страница 12: ...www plymovent com 0000101015 100821 F MistEliminator...

Отзывы: