0000101015/100821/F MistEliminator
2
PREFACE
Using this manual
This manual is intended to be used as a work of reference for
professional, well trained and authorised users to be able to
safely install, use, maintain and repair the product mentioned
on the cover of this document.
Pictograms and symbols
The following pictograms and symbols are used in this manual:
TIP
Suggestions and recommendations to simplify
carrying out tasks and actions.
ATTENTION
A remark with additional information for the user. A
remark brings possible problems to the user’s
attention.
CAUTION!
Procedures, if not carried out with the necessary
caution, could damage the product, the workshop or
the environment.
WARNING!
Procedures which, if not carried out with the
necessary caution, may damage the product or
cause serious personal injury.
CAUTION!
Denotes risk of electric shock.
WARNING!
Fire hazard! Important warning to prevent fire.
Personal protective equipment (PPE)
Instruction to use respiratory protection when you
do service, maintenance and repair jobs, as well as
during functional testing. We recommend to use a
half-face respirator according to EN 149:2001 +
A1:2009, class FFP3 (Directive 89/686/EEC).
Personal protective equipment (PPE)
Instruction to use protective gloves when you do
service, maintenance and repair jobs.
Text indicators
Listings indicated by “-” (hyphen) concern enumerations.
Listings indicated by “•” (bullet point) describe steps to
perform.
Service and technical support
For information about specific adjustments, maintenance or
repair jobs which are not dealt with in this manual, please
contact the supplier of the product. He will always be willing to
help you. Make sure you have the following specifications at
hand:
- product name
- serial number
You can find these data on the identification plate.
1
INTRODUCTION
1.1
Identification of the product
The identification plate contains, among other
things, the following data:
- product name
- serial number
- supply voltage and frequency
- power consumption
1.2
General description
The MistEliminator is a stationary filter for mainly oil mist
applications, to be used in machine tool processes. Depending
on the specific application, it is available with four different
filter packages
1
, with or without integrated fan module. In case
of recirculation it is recommended to use a MistEliminator with
additional HEPA filter (ME-32 and ME-42 series).
Except for the ME-42/F1 and ME-42/F2 with integrated fan,
the MistEliminator requires no power.
1.3
Options and accessories
The following products can be obtained as an option and/or
accessory:
ME-31/32/41/42 only:
- FUA fan series for direct mounting on MistEliminator
- FF-DUCT/250: duct connection Ø 250 mm
- FF-FAN/S: filter-fan adapter FUA-1800/2100
- FF-FAN/B: filter-fan adapter FUA-3000/4700
- FF-RACK: mounting frame
1.4
Technical specifications
Weight:
- ME-31
- ME-32
- ME-41
- ME-42
- ME-42/F1
- ME-42/F2
- 98 kg (207 lbs)
- 134 kg (295 lbs)
- 104 kg (229 lbs)
- 138 kg (304 lbs)
- 182 kg (401 lbs)
- 190 kg (419 lbs)
Filter efficiency
(ME-31/ME-41)
ISO ePM1 90% according to
EN ISO 16890
Filter class
(ME-32/ME-42/ME-42/F1/F2)
H13 according to EN 1822
Pressure drop:
- ME-31
- ME-32
- ME-41
- ME-42
(for dimensional purpose)
- 700 Pa (2.7 in. WG)
- 1200 Pa (4.75 in. WG)
- 1300 Pa (5.1 in. WG)
- 1500 Pa (6.0 in. WG)
Negative pressure
max. 4000 Pa (16 in. WG)
Airflow
*)
:
- ME-31/ME-32
- ME-41/ME-42
Max.:
-
3000 m
3/h (1750 CFM)
-
2000 m
3/h (1175 CFM)
Volume of oil container
8 liters (2 gallon)
*)
Max. airflow is a ceiling value and generally not recommended as a
design value for operating the ME unit, as it might lead to short
lifespan of filters. The performance of the ME unit is next to airflow
influenced by other variables like amount and composition of metal
working fluid, process, temperature and pre-treatment. Ask your local
expert on the recommended airflow for your system design.
Refer to the available product data sheets for
detailed product specifications.
1.5
Dimensions
1.
ME-31:
bag filter
; for “polluted” or burnt high viscosity oil/emulsion
ME-32:
bag HEPA filter
; for “polluted” or burnt high viscosity oil/
em recirculation
ME-41:
two-stage coalescer filter
; for “clean” or recycable low viscosity oil
ME-42 series:
two-stage coalescer HEPA filter
; for “clean” or
recycable low viscosity oil + recirculation