0000300349/230420/0 MDB-Diluter PRO
9
Fig. 4.11 Unpacking
90°
90°
2x
2x
4x
4x
A
A
B
1x
1x
A
B
C
1x
C
•
Remove dust, if any, from the edge surfaces of the filter
module.
•
Lay the seals loosely on the filter module and put them
together
14
.
•
Make sure that the jigsaws tightly fit.
Fig. 4.12
90°
90°
2x
2x
4x
4x
A
A
B
1x
1x
A
B
C
1x
C
Seals on filter module
• Start with a
long
seal (1046 mm).
• Try to avoid touching the sticky side with your
fingers.
• Make sure that you attach the seal in the
centre
of the edges and that the jigsaws fit together.
• Peel approx. 50 mm of the backing material (A) and stick
the seal on the filter module. Draw the backing material to
the
inside
of the filter module.
• Continue to peel and stick the seal in steps of approx. 50
mm according to the sequence below.
Fig. 4.13
A
± 50 mm
1
2
3
4
6
5
Removal of backing material
•
Lift and turn the filter module back to its original position.
•
Repeat the procedure for the other filter module.
14. Do not worry about a slight misalignment of the seal holes
Fig. 4.14
90°
90°
2x
2x
4x
4x
A
A
B
1x
1x
A
B
C
1x
C
Turning back
To replace a damaged or incorrectly applied seal, do
the following.
• Remove the damaged or incorrectly applied seal.
• Preferably: remove the remains of glue, if any,
from the filter module (e.g. with sticker
remover). Make sure that you do not damage
the undamaged seals.
• Apply a spare seal according to the above
instructions.
ATTENTION
General installation instructions
• Remove the backing material
before
you put
the pointed positioning studs on the frame and
filter module. Try to avoid touching the sticky
seals with your fingers.
• Always use SealApplicator lubricant on the
sealing material before you connect any
component of the MDB-Diluter system
15
.
By the use of SealApplicator you can slightly
shift the filter module to get the right position.
After approx. 60 seconds the lubricant is dry so
you cannot shift anymore.
•
Install one filter module at a time. After
spraying, immediately position the filter module
or any other component
16
.
Vertical connection of filter modules
9x
4x
5x
+
<60 s
1
4
4x
3
5
2
4x
Remove the filter lids and the round cover plates on
the back to have an easier access to the inside of
the filter modules for connection purposes.
4.5.1 Filter module on frame
• Put the MDB-FRAME (A) in fully horizontal position.
15.
The seals are extremely adhesive; without the use of SealApplicator,
components might stick together in the wrong position and cannot be
disconnected without damage.
16. After approx. 60 seconds SealApplicator lubricant loses its functions and you
cannot shift anymore