background image

0000104046/010822/A MDB-Compact PRO 

14

•  Seal the sack securely.
•  Put a new filter cartridge on the cartridge holder (A) and 

attach it with the disassembled parts.

•  Do the same procedure for the lower filter cartridge(s).
•  Empty the dust drawer with an industrial vacuum cleaner; 

refer to paragraph 6.2.

•  Connect the compressed air.
•  Energize the unit.
•  Dispose of the used filter cartridges in accordance with 

federal, state or local regulations.

•  Clean the environment of the unit.

Fig. 6.2 

B

A

D

C

E

F

Filter replacement

ATTENTION

Make sure that the front of the filter cartridge 

aligns

*)

 with the filter housing, so that the cover 

plate closes well. If this is not the case, the filter 

cartridge is not positioned correctly. This can cause 

leakage and less efficient operation of the filter 

cartridge.

*)

 tolerance: max. 2 mm (⅛ in.)

>2 mm

 max. 2 mm

>2 mm

 max. 2 mm

>2 mm

 max. 2 mm

>2 mm

 max. 2 mm

6.4 

Precoat (PRECO-N) / CART-D, CART-C and 

CART-E only (option)

•  Refer to paragraph 4.9 for the precoat procedure.

TROUBLESHOOTING

If the unit does not function (correctly), consult the 

checklist below to see if you can remedy the error 

yourself. Should this not be possible, contact your 

supplier.

WARNING

Obey the safety regulations that are written in 

chapter 3 when you carry out the activities below.

Symptom

Problem

Possible 

cause

Solution

Poor 

extraction 

capacity

The system 

does not 

function 

properly

Clogged filter 

cartridges

Replace the filter 

cartridges

Inverted 

direction of 

rotation of the 

motor of the 

connected fan

Change the 

direction of rotation

Pollution of 

the facility

Filter 

cartridge(s) 

ripped or 

placed 

incorrectly

Replace the filter 

cartridges(s) or 

place them 

correctly (ref. 

paragraph 6.3)

No filter 

cleaning

Loose 

compressed air 

connection

Repair the 

compressed air 

connection

No compressed 

air available or 

air pressure too 

low

Repair the 

compressed air 

supply

Membrane 

valve(s) 

defective

Replace the 

membrane valve(s)

No pressure 

in the 

compressed 

air tank

Drain valve is 

loose

Tighten the drain 

valve

Tank not 

connected to 

compressed air 

supply

Repair the 

compressed air 

connection

Hissing sound No filter 

cleaning

Membrane 

valve(s) 

defective or 

worn

Replace the 

membrane valve(s)

Wrong or 

damaged wiring

Correct or repair 

the wiring

SPARE PARTS

8.1 

MDB-Compact

Refer to the exploded view Fig. VI on page 20 

and spare parts list Fig. VII on page 21 for the 

available spare parts.

8.2 

ControlPro

Refer to the installation manual of the ControlPro.

ELECTRICAL DIAGRAM

Refer to the separately supplied electrical diagram.

Содержание MDB-2/Compact PRO

Страница 1: ...www plymovent com Central filter system with integrated fan MDB COMPACT PRO Installation and user manual EN...

Страница 2: ...as a guideline for installation use maintenance and repair of the product mentioned on the cover page of this document This publication is to be used for the standard model of the product of the type...

Страница 3: ...ions Product type Equals to MDB 2 Compact PRO MDB 2 C MDB 4 Compact PRO MDB 4 C MDB 6 Compact PRO MDB 6 C The specific product type 4 6 8 corresponds with the number of filter cartridges 1 INTRODUCTIO...

Страница 4: ...ction push in fitting in G in out 12 mm Electrical data Connection voltage fan 230V 3ph 60Hz 460V 3ph 60Hz 575V 3ph 60Hz The use of a frequency inverter makes the 60 Hz fan suitable to run on a 50 Hz...

Страница 5: ...xtensive feature package to monitor and arrange the RamAir pulse amplifier filter cleaning system the required airflow and the corresponding fan speed By means of the user friendly HMI you can program...

Страница 6: ...directions in the sales brochure In case of doubt it is the use which can be deduced from the construction the model and the function of the technical product which is considered normal use Operating...

Страница 7: ...the MDB 4 C and MDB 6 C are supplied separately to allow you to determine the desired inlet position4 The inlet position of the MDB 2 C is fixed Make sure that the product is complete The package con...

Страница 8: ...orm or frame image of frame is indicative only 4 5 Air inlet module and cover plate MDB 2 C The air inlet module and the cover plate are pre installed on a fixed position MDB 4 C and MDB 6 C The air i...

Страница 9: ...with the eye bolts5 Fig 4 6 If you have installed the cover plate on the left Put blinding plugs A in the remaining holes Fig 4 6 A 8x Blinding plugs 5 You must install the corner plates to make the u...

Страница 10: ...PE Wear respiratory protection and protective gloves when you apply precoat material Necessary quantity of precoat MDB 2 C 1 kg 2 lbs MDB 4 C 2 kg 4 lbs MDB 6 C 3 kg 6 lbs To apply precoat material to...

Страница 11: ...d protective gloves when you empty the dust drawer ATTENTION The industrial vacuum cleaner that you use to empty the dust drawer must meet dust class H according to EN 60335 2 69 or HEPA class efficie...

Страница 12: ...the safety regulations that are written in chapter 3 when you carry out the activities below Symptom Problem Possible cause Solution Poor extraction capacity The system does not function properly Clog...

Страница 13: ...fter dismantling of the unit clean the dismantling area 10 2 Disposal Dispose of the pollutants and dust together with the used filter cartridges in a professional manner in accordance with federal st...

Страница 14: ...Dimensions MDB 2 Compact MDB 4 Compact MDB 6 Compact Front view B C A B C A B C A mm inch mm inch mm inch A 1348 53 1801 70 2004 78 B 1502 59 1955 77 2158 85 C 1186 46 1190 46 1641 64 Top view D D D...

Страница 15: ...1500 2000 2500 3000 3500 1000 2000 3000 4000 5000 6000 7000 8000 Pressure Pa Airflow m h 1000 1500 2000 2500 3000 Airflow cfm 3500 Pressure in WG 2 4 6 8 10 12 MDB 2 COMPACT MDB 4 COMPACT MDB 6 COMPAC...

Страница 16: ...0000104046 010822 A MDB Compact PRO 18 ANNEX Fig III Lifting instructions max 45 90...

Страница 17: ...C C C C F C D E G M10x25 C A B MDB 2 Compact MDB 4 Compact MDB 6 Compact mm inch mm inch mm inch A 1198 47 1205 47 1205 47 B 908 35 908 35 908 35 C 76 3 76 3 76 3 D 1199 47 1649 64 1849 72 E 1516 59...

Страница 18: ...10003 0000110004 0000102598 0000100351 6x 0000102666 0000103126 0000103127 0000100344 0000100345 0000100346 0000103139 0000103142 0000301426 0000103148 0000102530 0000102532 0000103162 0000100539 0000...

Страница 19: ...Filter cartridge 0000117907 Coil 24V DC incl connector 0000117908 Membrane square spring for magnetic valve 0000301426 Filter cartridge holder MDB 0069002280 PRECO N 14 kg Precoat material 0806010120...

Страница 20: ...www plymovent com 0000104046 010822 A MDB Compact PRO...

Отзывы: