1.8 

Ambient and process conditions

Process temperature:

 

-

min.

 

-

nom.

 

-

max.

5°C (41°F)

20°C (68°F)

70°C (158°F)

Max. relative humidity

80%

Suitable for outdoor use

no

1.9 

Transport of the unit

You cannot hold the manufacturer liable for any transportation 

damage after delivery of the unit. Handle the unit and the 

accompanying options and/or accessories, if any, with care.

Refer to paragraph 4.3 for lifting instructions.

PRODUCT DESCRIPTION

2.1 

Components

The MDB-Compact consists of the following main components 

and elements:

Fig. 2.1

Corner plate with eye bolt (4)

Cover plate 

RamAir™ pulse amplifier (filter cleaning system), incl. 

compressed air tank

Air inlet module

E  Dust drawer

F  Filter cartridge (2/4/6)

G  Extraction fan

H  Air outlet

ControlPro/Panel

ControlPro/HMI

Fig. 2.1 

C

D

B

E

H

I

J

G

F

A (4x)

Main components and elements

2.2 

Operation

The polluted air from the external device is 

extracted through the air inlet module on the left

2

 

side of the unit. The air then passes the filter 

cartridges inside the housing. The filtered air is blown back 

into the workshop by the outlet of the fan housing.

The filter cartridges are cleaned individually by compressed air 

pulses. This system is called the RamAir™ pulse amplifier. The 

dust and dirt particles are collected in the dust drawer.

Deflector plates behind the air inlet module balance the dust 

load on the filter cartridges. They operate as spark arresters at 

the same time.

2.2.1  Control equipment

The MDB-Compact is connected to ControlPro control 

equipment.

ControlPro is an intelligent platform that controls the filter 

system as well as the connected extraction fan. It contains an 

extensive feature package to monitor and arrange the 

RamAir™ pulse amplifier (filter cleaning system), the required 

airflow and the corresponding fan speed. By means of the 

user-friendly HMI you can program all desired parameters. The 

HMI gives a clear insight into the system status and 

performance at all times.

ControlPro allows for remote access via a network connection.

SAFETY INSTRUCTIONS

General

The manufacturer does not accept any liability for 

damage to the product or personal injury caused by 

ignoring of the safety instructions in this manual, or 

by negligence during installation, use, maintenance, and repair 

of the product mentioned on the cover of this document and 

any corresponding accessories.

 

Specific working conditions or used accessories may require 

additional safety instructions. Immediately contact your 

supplier if you detect a potential danger when using the 

product.

The user of the product is always fully responsible for 

observing the local safety instructions and regulations. 

Obey all applicable safety instructions and regulations.

User manual

 

-

Everyone working on or with the product, must be familiar 

with the contents of this manual and must strictly observe 

the instructions therein. The management should instruct the 

personnel in accordance with the manual and observe all 

instructions and directions given.

 

-

Do not change the order of the steps to perform.

 

-

Always keep the manual with the product.

Pictograms and instructions on the product (if 

present)

 

-

The pictograms, warning and instructions attached to the 

product are part of the safety features. They must not be 

covered or removed and must be present and legible during 

the entire life of the product.

 

-

Immediately replace or repair damaged or illegible 

pictograms, warnings and instructions.

2.

  In case of an MDB-4/C and MDB-6/C, it is possible to install the air inlet 

module on top of the unit

Содержание MDB-2/Compact PRO

Страница 1: ...www plymovent com Central filter system with integrated fan MDB COMPACT PRO Installation and user manual EN...

Страница 2: ...as a guideline for installation use maintenance and repair of the product mentioned on the cover page of this document This publication is to be used for the standard model of the product of the type...

Страница 3: ...ions Product type Equals to MDB 2 Compact PRO MDB 2 C MDB 4 Compact PRO MDB 4 C MDB 6 Compact PRO MDB 6 C The specific product type 4 6 8 corresponds with the number of filter cartridges 1 INTRODUCTIO...

Страница 4: ...ction push in fitting in G in out 12 mm Electrical data Connection voltage fan 230V 3ph 60Hz 460V 3ph 60Hz 575V 3ph 60Hz The use of a frequency inverter makes the 60 Hz fan suitable to run on a 50 Hz...

Страница 5: ...xtensive feature package to monitor and arrange the RamAir pulse amplifier filter cleaning system the required airflow and the corresponding fan speed By means of the user friendly HMI you can program...

Страница 6: ...directions in the sales brochure In case of doubt it is the use which can be deduced from the construction the model and the function of the technical product which is considered normal use Operating...

Страница 7: ...the MDB 4 C and MDB 6 C are supplied separately to allow you to determine the desired inlet position4 The inlet position of the MDB 2 C is fixed Make sure that the product is complete The package con...

Страница 8: ...orm or frame image of frame is indicative only 4 5 Air inlet module and cover plate MDB 2 C The air inlet module and the cover plate are pre installed on a fixed position MDB 4 C and MDB 6 C The air i...

Страница 9: ...with the eye bolts5 Fig 4 6 If you have installed the cover plate on the left Put blinding plugs A in the remaining holes Fig 4 6 A 8x Blinding plugs 5 You must install the corner plates to make the u...

Страница 10: ...PE Wear respiratory protection and protective gloves when you apply precoat material Necessary quantity of precoat MDB 2 C 1 kg 2 lbs MDB 4 C 2 kg 4 lbs MDB 6 C 3 kg 6 lbs To apply precoat material to...

Страница 11: ...d protective gloves when you empty the dust drawer ATTENTION The industrial vacuum cleaner that you use to empty the dust drawer must meet dust class H according to EN 60335 2 69 or HEPA class efficie...

Страница 12: ...the safety regulations that are written in chapter 3 when you carry out the activities below Symptom Problem Possible cause Solution Poor extraction capacity The system does not function properly Clog...

Страница 13: ...fter dismantling of the unit clean the dismantling area 10 2 Disposal Dispose of the pollutants and dust together with the used filter cartridges in a professional manner in accordance with federal st...

Страница 14: ...Dimensions MDB 2 Compact MDB 4 Compact MDB 6 Compact Front view B C A B C A B C A mm inch mm inch mm inch A 1348 53 1801 70 2004 78 B 1502 59 1955 77 2158 85 C 1186 46 1190 46 1641 64 Top view D D D...

Страница 15: ...1500 2000 2500 3000 3500 1000 2000 3000 4000 5000 6000 7000 8000 Pressure Pa Airflow m h 1000 1500 2000 2500 3000 Airflow cfm 3500 Pressure in WG 2 4 6 8 10 12 MDB 2 COMPACT MDB 4 COMPACT MDB 6 COMPAC...

Страница 16: ...0000104046 010822 A MDB Compact PRO 18 ANNEX Fig III Lifting instructions max 45 90...

Страница 17: ...C C C C F C D E G M10x25 C A B MDB 2 Compact MDB 4 Compact MDB 6 Compact mm inch mm inch mm inch A 1198 47 1205 47 1205 47 B 908 35 908 35 908 35 C 76 3 76 3 76 3 D 1199 47 1649 64 1849 72 E 1516 59...

Страница 18: ...10003 0000110004 0000102598 0000100351 6x 0000102666 0000103126 0000103127 0000100344 0000100345 0000100346 0000103139 0000103142 0000301426 0000103148 0000102530 0000102532 0000103162 0000100539 0000...

Страница 19: ...Filter cartridge 0000117907 Coil 24V DC incl connector 0000117908 Membrane square spring for magnetic valve 0000301426 Filter cartridge holder MDB 0069002280 PRECO N 14 kg Precoat material 0806010120...

Страница 20: ...www plymovent com 0000104046 010822 A MDB Compact PRO...

Отзывы: