![Plymovent MDB-2/C Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/plymovent/mdb-2-c/mdb-2-c_installation-and-user-manual_1569287012.webp)
0000104046
/150915/0 MultiDust Bank COMPACT
EN - 11
5. Move the ‘>’ cursor to ‘
clock
’: Press
q
or
p
.
6. Press
OK
.
7. Move the ‘>’ cursor to ‘
Set clock
’: Press
q
or
p
.
8. Apply ‘Set Clock’: Press
OK
.
The display shows (example):
Set Clock
Mo 15:30
YYYY-MM-DD
2015-03-23
9. Select the day of the week: Press
q
or
p
.
10. Move the ‘>’ cursor to the next position: Press
t
or
u
.
11. To change the time: Press
q
or
p
.
12. To set the correct time of day, repeat the previous steps 10
and 11.
13. To set the correct date, repeat steps 10 and 11.
14. To confirm the entries: Press
OK
.
15. Press
ESc
(2x).
Summertime/wintertime
To set summertime/wintertime, proceed as follows.
1. Press
q
to show time + date.
2. Press
ESc
.
3. Select ‘
Set
..’ Press
q
or
p
.
4. Press
OK
.
5. Move the ‘>’ cursor to ‘
clock
’: Press
q
or
p
.
6. Press
OK
.
7. Move the ‘>’ cursor to ‘
S/W Time
’: Press
q
or
p
.
8. Press
OK
.
The display shows:
>On
Off
S/W Time
Off
9. Move the ‘>’ cursor to ‘
On
’: Press
q
or
p
.
10. Confirm ‘On’: Press
OK
.
The display shows:
EU
11. Press
u
to select the applicable time zone.
12. Press
OK
.
The display shows (assuming you have set European time):
>On
Off
SW/Time:
On
EU
Europe/UK/US/Australia/Tasmania/New Zealand/Freely
adjustable: customized switchover dates and times.
4.11 commissioning checklist
#
check
Ref.
section
OK
1.
Are all connections airtight?
2.
Is the jumper setting correct?
3.
Is the direction of rotation of the fan
correct?
#
check
Ref.
section
OK
4.
Is compressed air available?
Pressure setting 4-5 bar?
5.
Is the parameter setting of the PLC
correct?
6.
Is the rotary switch in position 1?
5
USE
WARNINg!
Fire hazard! Do
not
use the product for polishing
applications in combination with grinding, welding or
any other application that generate sparks.
5.1
Filtercontrol panel
The FilterControl panel contains the following controls and
indicator lights:
controls
A Push button
START/STOP FAN
B Push button
MANUAL CLEANING
- reset alarm
push shortly
- manual
cleaning
push and hold for 5 seconds; the red
light (E) starts blinking
- precoat timer
reset
push and hold for 10 seconds; the red
light (E) stops blinking
C
Rotary switch 0-1
Indicator lights
Off
On
D White light
Power off
Power on
E Red light
11
System OK
Cleaning cycle not
successful because:
- filter cartridges are
clogged; or
- no compressed air is
available
F Green light
Fan off
Fan on
11
Fig. 5.1
POWER ON
FAN RUNNING
MANUAL CLEANING
START/STOP FAN
0
1
ALARM
0000104051/0
D
E
F
A
B
C
Control panel
11. Option: additional strobe light to meet the IFA W3 certification requirements.