PRODUCT DESCRIPTION

2.1 

Components

The product consists of the following main components and 

elements:

Fig. 2.1

A  Wall bracket

4

B  Rotating hinge

Connection flange

D  Inner tube

E  Middle hinge

F  Outer tube

G  Hose

Shut-off & control valve

I  Hood

Fig. 2.1 

C

A

B

D

E

G
H

I

F

Main components and elements

2.2 

Operation

The welding fume is extracted through the hood of the arm by 

a single or central fan. The extraction arm discharges the 

polluted air to an extraction duct with filter unit or directly to 

the atmosphere. 

The hood of the arm is fitted with a valve to shut off or 

regulate the airflow. The shut-off valve is mostly used when 

several extraction arms are integrated in a line installation; in 

such configurations closing the valve prevents the loss of 

costly heated air.

SAFETY

General

The manufacturer does not accept any liability for 

damage to the product or personal injury caused by 

ignoring of the safety instructions in this manual, or 

by negligence during installation, use, maintenance, and repair 

of the product mentioned on the cover of this document and 

any corresponding accessories. Specific working conditions or 

used accessories may require additional safety instructions. 

Immediately contact your supplier if you detect a potential 

danger when using the product.

The user of the product is always fully responsible 

for observing the local safety instructions and 

4.  Not applicable for 

S

 types

regulations. Observe all applicable safety 

instructions and regulations.

User manual

 

- Everyone working on or with the product, must be familiar 

with the contents of this manual and must strictly observe 

the instructions therein. The management should instruct the 

personnel in accordance with the manual and observe all 

instructions and directions given. 

 

- Do not change the order of the steps to perform.

 

- Keep the manual with the product. 

Users

 

- The use of this product is exclusively reserved to authorised, 

trained and qualified users. Temporary personnel and 

personnel in training can only use the product under 

supervision and responsibility of skilled engineers. 

 

- Stay alert and keep your attention to your work. Do not use 

the product when you are under the influence of drugs, 

alcohol or medicine. 

 

- The product is not to be used by children or persons with 

reduced physical, sensory or mental capabilities, or lack of 

experience and knowledge, unless they have been given 

supervision or instruction. 

 

- Children must be supervised not to play with the product.

Intended use

5

The product has been designed exclusively for extracting 

fumes and particles which are released during the most 

common welding and cutting processes. Using the product for 

other purposes is considered contrary to its intended use. The 

manufacturer accepts no liability for any damage or injury 

resulting from such use. The product has been built in 

accordance with state-of-the-art standards and recognised 

safety regulations. Only use this product when in technically 

perfect condition in accordance with its intended use and the 

instructions explained in the user manual.

Technical specifications

Do not change the specifications given in this manual. 

Modifications

Modification of (parts of) the product is not allowed.

Product combinations

If the product is used in combination with other products or 

machines, the safety instructions in the documentation of 

these products also apply.

Installation

 

- The installation of this product is exclusively reserved to 

authorised, trained and qualified engineers. 

 

- During installation, always use Personal Protective 

Equipment (PPE) to avoid injury. This also applies to persons 

who enter the work area during installation.

 

-

Use sufficient climbing gear and safety guards when working 

on a higher level than 2 metres (local restrictions may 

apply). 

 

- Do not install the product in front of entrances and exits 

which must be used for emergency services. 

 

- Mind any gas and water pipes and electric cables.

 

- Make sure that the workspace is well illuminated. 

5.  “Intended use” as explained in EN-ISO 12100-1 is the use for which the 

technical product is suited as specified by the manufacturer, inclusive of his 

directions in the sales brochure. In case of doubt it is the use which can be 

deduced from the construction, the model and the function of the technical 

product which is considered normal use. Operating the machine within the 

limits of its intended use also involves observing the instructions in the user 

manual.

Содержание KUA-200/3H

Страница 1: ...www plymovent com Extraction arm KUA 200 H S ATEX Installation and user manual EN...

Страница 2: ...lation use maintenance and repair of the product mentioned on the cover page of this document This publication is to be used for the standard model of the product of the type given on the cover page T...

Страница 3: ...ral description The KUA 200 is an extraction arm with an external middle hinge The removable hood has a safety mesh The arm is fitted with a sealed shut off control valve and is 360 rotatable The hood...

Страница 4: ...p your attention to your work Do not use the product when you are under the influence of drugs alcohol or medicine The product is not to be used by children or persons with reduced physical sensory or...

Страница 5: ...n lead to high costs for repair and revisions and can render the guarantee null and void Always use Personal Protective Equipment PPE to avoid injury This also applies for persons who enter the work a...

Страница 6: ...6 B 170 6 7 m ft C 2 2 3 6 5 7 5 mm F D 13 9000 N Fig 4 2 Mounting of the wall bracket 4 5 3 Aluminium collar Fig 4 3 Put the collar D over the hinge rod C of the arm Put the clamping pin B through t...

Страница 7: ...the connection flange In that case proceed with paragraph 4 6 Fig 4 8 Option8 cut the upper part of the flange to increase the diameter from 160 to 200 mm A B Install the connection flange C on the w...

Страница 8: ...required which are described in this chapter If you observe the necessary caution and carry out the maintenance at regular intervals any problems occurring will be detected and corrected before they...

Страница 9: ...fter life of the product dispose of it in accordance with federal state or local regulations CE DECLARATION CE declaration of conformity for machinery We Plymovent Manufacturing B V Koraalstraat 9 181...

Страница 10: ...reach C B A D KUA 200 3 KUA 200 4 mm inch mm inch A 1150 45 3 1450 57 1 B 1450 57 1 1620 63 8 C 3440 135 4 4130 162 6 Fig II Pressure drop 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 500 700...

Страница 11: ...ANNEX Fig III Exploded view H S 0000101938 0000101935 0000113691 0000115713 0000115716 0000115714 0000115717 0000115715 0000115718 0000115724 0000115726 0000115723 0000115725 0000115720 0000115722 00...

Страница 12: ...1000 mm 205 mm incl 2 hose clamps 2 rubber collars 0000115714 Hose L 650 mm 205 mm incl 2 hose clamps 2 rubber collars 0000115715 Hose L 450 mm 205 mm incl 2 hose clamps 2 rubber collars 0000115725 Ou...

Страница 13: ...www plymovent com 0000113485 011020 B KUA 200...

Отзывы: