background image

0000113485/011020/B KUA-200 

2

PREFACE

Using this manual

This manual is intended to be used as a work of reference for 

professional, well trained and authorised users to be able to 

safely install, use, maintain and repair the product mentioned 

on the cover of this document.

Pictograms and symbols

The following pictograms and symbols are used in this manual:

TIP

Suggestions and recommendations to simplify 

carrying out tasks and actions.

ATTENTION

A remark with additional information for the user. A 

remark brings possible problems to the user’s 

attention.

CAUTION!

Procedures, if not carried out with the necessary 

caution, could damage the product, the workshop or 

the environment. 

WARNING!

Procedures which, if not carried out with the 

necessary caution, may damage the product or 

cause serious personal injury. 

WARNING!

Fire hazard! Important warning to prevent fire. 

WARNING!

Explosion hazard! Important warning to prevent 

explosions. 

Personal protective equipment (PPE)

Instruction to use respiratory protection when you 

do service, maintenance and repair jobs, as well as 

during functional testing. We recommend to use a 

half-face respirator according to EN 149:2001 + 

A1:2009, classe FFP3 (Directive 89/686/EEC).

Personal protective equipment (PPE)

Instruction to use protective gloves when you do 

service, maintenance and repair jobs.   

Text indicators

Listings indicated by “-” (hyphen) concern enumerations. 

Listings indicated by “•” (bullet point) describe steps to 

perform. 

INTRODUCTION

1.1 

Identification of the product

The identification plate contains, among other things, the 

following data:

 

- product name

 

- serial number

1.2 

General description

The KUA-200 is an extraction arm with an external middle 

hinge. The removable hood has a safety mesh. The arm is 

fitted with a sealed shut-off & control valve and is 360° 

rotatable. The hood is 85° movable in four directions. 

The KUA-200 arm is available in three different types:

 

- type 

H

: for hanging mounting (wall bracket included)

 

- type 

S

: for standing mounting

1

1.  Future development

 

- type 

ATEX

: approved for use in explosive environments 

Zone 22; marking EX II 3D (for hanging mounting only)

2

1.3 

Options and accessories

Arm-fan adapter 

for connection of the KUA-200 with a fan

3

1.4 

Product combinations

You can use the KUA-200 with the following products:

Extraction fan

 

- FUA-1800 | 0,55 kW (0.75 HP)

 

- FUA-2100 | 0,75 kW (1 HP)

 

- FUA-3000 | 1,1 kW (1.5 HP)

Extension crane

 

- FlexMax-15/200 | 1,5 m (5 ft)

 

- FlexMax-25/200 | 2,5 m (8.2 ft)

 

- FlexMax-35/200 | 3,5 m (11.5 ft)

 

- FlexMax-45/200 | 4,5 m (15 ft)

Stanchion

 

- PA-110/200 | 1,1 m (3.6 ft)

 

- PA-220/200 | 2,2 m (7.2 ft)

1.5 

Technical specifications

Physical dimensions and properties

Length:

 

- KUA-200/3

 

- KUA-200/4

 

- 3 m (9.8 ft)

 

- 4 m (13.1 ft)

Diameter:

 

- tubes

 

- hood opening

 

- Ø 200 mm (7.9 in.)

 

- Ø 340 mm (13.4 in.)

Material of tubes

aluminium

Material of hoses:

 

- type 

H

 and 

S

 

- type 

ATEX

 

- PVC with spring steel wire

 

- polyethylene with copper 

coated spring steel wire 

Weight:

 

- KUA-200/3

 

- KUA-200/4

 

- wall bracket (

H

 types)

 

- 34 kg (75 lbs.)

 

- 36 kg (79 lbs.)

 

- 5 kg (11 lbs.)

Performance

Recommended airflow

max. 1600 m³/h (940 CFM)

1.6 

Working reach

Refer to Fig. I on page 9.

1.7 

Pressure drop

Refer to Fig. II on page 9.

Refer to the available product data sheet for 

detailed product specifications.

1.8 

Ambient and proces conditions

Process temperature:

 

- min.

 

- nom.

 

- max.

 

-

5°C (41°F)

 

-

20°C (68°F)

 

-

70°C (158°F)

Max. relative humidity

90%

Outdoor use allowed

no

2.

  In accordance with TRGS 727 & ATEX Directive 2014/34/EU

3.  Suitable types: FUA-1800 | FUA-2100 | FUA-3000

Содержание KUA-200/3H

Страница 1: ...www plymovent com Extraction arm KUA 200 H S ATEX Installation and user manual EN...

Страница 2: ...lation use maintenance and repair of the product mentioned on the cover page of this document This publication is to be used for the standard model of the product of the type given on the cover page T...

Страница 3: ...ral description The KUA 200 is an extraction arm with an external middle hinge The removable hood has a safety mesh The arm is fitted with a sealed shut off control valve and is 360 rotatable The hood...

Страница 4: ...p your attention to your work Do not use the product when you are under the influence of drugs alcohol or medicine The product is not to be used by children or persons with reduced physical sensory or...

Страница 5: ...n lead to high costs for repair and revisions and can render the guarantee null and void Always use Personal Protective Equipment PPE to avoid injury This also applies for persons who enter the work a...

Страница 6: ...6 B 170 6 7 m ft C 2 2 3 6 5 7 5 mm F D 13 9000 N Fig 4 2 Mounting of the wall bracket 4 5 3 Aluminium collar Fig 4 3 Put the collar D over the hinge rod C of the arm Put the clamping pin B through t...

Страница 7: ...the connection flange In that case proceed with paragraph 4 6 Fig 4 8 Option8 cut the upper part of the flange to increase the diameter from 160 to 200 mm A B Install the connection flange C on the w...

Страница 8: ...required which are described in this chapter If you observe the necessary caution and carry out the maintenance at regular intervals any problems occurring will be detected and corrected before they...

Страница 9: ...fter life of the product dispose of it in accordance with federal state or local regulations CE DECLARATION CE declaration of conformity for machinery We Plymovent Manufacturing B V Koraalstraat 9 181...

Страница 10: ...reach C B A D KUA 200 3 KUA 200 4 mm inch mm inch A 1150 45 3 1450 57 1 B 1450 57 1 1620 63 8 C 3440 135 4 4130 162 6 Fig II Pressure drop 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 500 700...

Страница 11: ...ANNEX Fig III Exploded view H S 0000101938 0000101935 0000113691 0000115713 0000115716 0000115714 0000115717 0000115715 0000115718 0000115724 0000115726 0000115723 0000115725 0000115720 0000115722 00...

Страница 12: ...1000 mm 205 mm incl 2 hose clamps 2 rubber collars 0000115714 Hose L 650 mm 205 mm incl 2 hose clamps 2 rubber collars 0000115715 Hose L 450 mm 205 mm incl 2 hose clamps 2 rubber collars 0000115725 Ou...

Страница 13: ...www plymovent com 0000113485 011020 B KUA 200...