background image

4700 Series Fans

USA

:  115 Melrich Road 

Cranbury, NJ  08512   800-644-0911 

Canada

:  24-1200 Aerowood Drive 

Mississauga, ON  L4W 2S7   800.465.0327 

PlymoVent certifies that the 4700 Series Fans shown herein are licensed to bear the AMCA Seal.  The 

ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 

and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. 

Catalog Edition:  PLY-FAN0800.4700   

Date of Issue:  August 2000 

www.Plymovent.com

Performance shown is for installation type D – Ducted inlet, Ducted outlet.   

Maximum input horsepower:  3.628 Hp 

Performance ratings include the effects of inlet and outlet grilles in the airstream. 

Speed (RPM) shown is nominal.  Performance is based on actual speed of test.

FAN SPECIFICATIONS 

MOTOR SPECIFICATIONS 

Type 

Centrifugal Direct-Drive 

Motor HP 

Frequency 

Frame 

RPM

Construction 

AMCA Type B 

3.0

60 Hz

56C*

3450

Inlet Size Diameter 

9.8” (250mm)

Outlet Size 

5.6” x 11.2” (142 x 285 mm) 

Product No. 

Phase

Volts

FL Amps 

Impeller Diameter 

15.0” (380mm) 

4700-1-AM

3

208-230/460

8.4-7.6/3.8

Impeller/Housing 

Aluminum/Steel

4700-2-AM

3

575

3.0

Fan and Motor Wt 

95 lbs. (43 kg) 

4701-AM

1

115/230

13.5/6.75

 

 

 

 

 

                * - 1 phase and 575V motors have NEMA 145T frame 

Sound Power Levels 

Octave Band Number & Center Frequency Number 

1

2

3

4

5

6

7

8

Static

Pressure

(in wg) 

Airflow 

CFM

63

125

250

500

1K

2K

4K

8K

0

2614

99

93

92

93

92

91

87

86

2.4

2343

98

95

94

93

92

90

85

83

5

2040

98

95

93

92

89

87

82

80

8.05

1528

95

92

96

91

86

85

80

77

The sound power level ratings shown are in decibels, referred to as 10

-12

 watts calculated per AMCA Standard 301.  Values shown are for 

outlet L

Wo

 sound power levels for installation Type D, ducted inlet, ducted outlet.  Ratings include the effects of duct end correction for

outlet ducts. 

0

1

2

3

4

5

6

7

8

9

10

11

12

0

200

400

600

800

1000

1200

1400

1600

1800

2000

2200

2400

2600

A irflow , C FM

Static 

Pressure, 

in 

wg

FUA-4700

0000103355/240315/A FUA-1800/2100/2700/3000/4700 (60Hz) 

 13

Содержание FUA-1800

Страница 1: ...www plymovent com EN Extraction fan 60Hz EN User manual FUA 1800 2100 2700 3000 4700...

Страница 2: ...amend is hereby expressly reserved Changes may be made with or without notification It is the user s responsibility to ensure they have attained the most recent copy of this document for their files...

Страница 3: ...e FUA is an extraction fan that is specially designed to remove welding and other fumes dust oil mist and exhaust gases The fan is intended and designed for mounting to filter units and vehicle exhaus...

Страница 4: ...present The pictograms warning and instructions attached to the product are part of the safety features They must not be covered or removed and must be present and legible during the entire life of th...

Страница 5: ...Safety features which have been removed for service maintenance or repairs must be put back immediately after finishing these jobs and it must be checked that they still function properly 4 Installat...

Страница 6: ...position Loosen the 2 socket screws of the hub and remove the fan wheel B Loosen the 4 bolts C Turn the motor plate A 90 clockwise or counterclockwise Install the disassembled parts in reverse order F...

Страница 7: ...advise the use of a square to round outlet transition To connect the fan to a duct proceed as follows Fig 4 8 Loosen the bolts of the outlet grid A Remove the grid Attach the outlet transition to the...

Страница 8: ...The following spare parts are available for the product Refer to the exploded views FUA 1800 2100 2700 Fig III on page 14 FUA 3000 4700 Fig IV on page 15 Article no Description FUA 1800 0 75 HP 00001...

Страница 9: ...75 6 66 977 89 91 95 94 86 82 75 72 FUA 4700 0 2614 99 93 92 93 92 91 87 86 2 4 2343 98 95 94 93 92 90 85 83 5 2040 98 95 93 92 89 87 82 80 8 05 1528 95 92 96 91 86 85 80 77 Sub table B Conversion of...

Страница 10: ...5 7 145 5 7 D 1 403 15 9 403 15 9 430 16 9 489 19 3 508 20 0 3 375 14 8 375 14 8 400 15 8 459 18 1 478 18 8 E 455 17 9 455 17 9 455 17 9 512 20 2 591 23 3 F 244 9 6 244 9 6 244 9 6 228 9 0 258 10 2 G...

Страница 11: ...00 91 91 87 86 82 76 2 4 715 105 98 89 88 83 83 78 71 4 8 530 100 99 87 86 81 80 74 68 7 15 331 104 97 81 82 79 76 70 65 The sound power level ratings shown are in decibels referred to as 10 12 watts...

Страница 12: ...79 74 5 35 700 83 84 88 84 83 79 76 71 7 75 500 80 82 88 87 85 79 74 70 The sound power level ratings shown are in decibels referred to as 10 12 watts calculated per AMCA Standard 301 Values shown are...

Страница 13: ...Type B 3 0 60 Hz 56C 3450 Inlet Size Diameter 9 8 250mm Outlet Size 5 6 x 11 2 142 x 285 mm Product No Phase Volts FL Amps Impeller Diameter 15 0 380mm 4700 1 AM 3 208 230 460 8 4 7 6 3 8 Impeller Hou...