E
4700 Series Fans
USA
: 115 Melrich Road
Cranbury, NJ 08512 800-644-0911
Canada
: 24-1200 Aerowood Drive
Mississauga, ON L4W 2S7 800.465.0327
PlymoVent certifies that the 4700 Series Fans shown herein are licensed to bear the AMCA Seal. The
ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211
and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
Catalog Edition: PLY-FAN0800.4700
Date of Issue: August 2000
www.Plymovent.com
Performance shown is for installation type D – Ducted inlet, Ducted outlet.
Maximum input horsepower: 3.628 Hp
Performance ratings include the effects of inlet and outlet grilles in the airstream.
Speed (RPM) shown is nominal. Performance is based on actual speed of test.
FAN SPECIFICATIONS
MOTOR SPECIFICATIONS
Type
Centrifugal Direct-Drive
Motor HP
Frequency
Frame
RPM
Construction
AMCA Type B
3.0
60 Hz
56C*
3450
Inlet Size Diameter
9.8” (250mm)
Outlet Size
5.6” x 11.2” (142 x 285 mm)
Product No.
Phase
Volts
FL Amps
Impeller Diameter
15.0” (380mm)
4700-1-AM
3
208-230/460
8.4-7.6/3.8
Impeller/Housing
Aluminum/Steel
4700-2-AM
3
575
3.0
Fan and Motor Wt
95 lbs. (43 kg)
4701-AM
1
115/230
13.5/6.75
* - 1 phase and 575V motors have NEMA 145T frame
Sound Power Levels
Octave Band Number & Center Frequency Number
1
2
3
4
5
6
7
8
Static
Pressure
(in wg)
Airflow
CFM
63
125
250
500
1K
2K
4K
8K
0
2614
99
93
92
93
92
91
87
86
2.4
2343
98
95
94
93
92
90
85
83
5
2040
98
95
93
92
89
87
82
80
8.05
1528
95
92
96
91
86
85
80
77
The sound power level ratings shown are in decibels, referred to as 10
-12
watts calculated per AMCA Standard 301. Values shown are for
outlet L
Wo
sound power levels for installation Type D, ducted inlet, ducted outlet. Ratings include the effects of duct end correction for
outlet ducts.
0
1
2
3
4
5
6
7
8
9
10
11
12
0
200
400
600
800
1000
1200
1400
1600
1800
2000
2200
2400
2600
A irflow , C FM
Static
Pressure,
in
wg
FUA-4700
0000103355/240315/A FUA-1800/2100/2700/3000/4700 (60Hz)