![Plymovent CONTROLPRO Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/plymovent/controlpro/controlpro_short-user-manual_1569225018.webp)
130519/A ControlPro | Short user manual
EN - 18
Fig. 4.5 Filter cleaning menu
!
Pressure controlled and time controlled cleaning can run simultaneously.
4.2.1 Pressure controlled cleaning
| menu 3.1
To optimize the filter lifespan while minimizing the required amount of compressed air,
ControlPro applies progressive filter cleaning. This means that the filter cleaning intensity
is adapted to the actual pressure over the filter cartridges, according to certain preset
threshold values.
The pressure gauge on the filter cleaning status window
shows the actual filter pressure (example: 639 Pa).
The scale marks show the thresholds values that activate
the filter cleaning system.
Fig. 4.6 Filter cleaning status window
The pressure controlled cleaning cycles are activated in accordance with the set threshold
values. If you want to change the cleaning frequency for some reason, you must adapt
the threshold values.
White marks:
- TH1 = threshold value 1
- TH2 = threshold value 2
- TH3 = threshold value 3
- TH4 = threshold value 4
Orange mark:
-
filters clogged
Fig. 4.7 Threshold values
The images below show the default settings.
Fig. 4.8
Default settings
Содержание CONTROLPRO
Страница 1: ...www plymovent com CONTROLPRO EN Short user manual ...
Страница 32: ...www plymovent com ...