0000112607/010420/A ControlGo
8
Cable #1
A
C
B
D
(CAN IN)
E (2x)
Fig. 4.9 Connection of SlaveBoard
• Cut the cable to the necessary length for connection to the
Panel.
Indicator LED’s
Valves
Digital input 1-5
CAN Slave
Digital input 6-12
Filter Pressure
sensor
Light tower
Power
Rela
y 1
R
ela
y 2
+
-
Cable #1
Indicator LED’s
Valves
Dustbin
sensor
Fan Pressure
sensor
Digital input 1-5
RS485 VFD
CAN Slave
CAN HMI
Digital input 6-12
Filter Pressure
sensor
Analog
output
Light tower
Power
Rela
y 1
R
ela
y 2
Ethernet
(for service only)
USB
(firmware updates)
RS-232
(for service only)
Filter pressure
(internal sensor)
Fan pressure
(internal sensor)
+
-
+
-
Valves
1
+ 24V
2
OUT 1
3
GND
4
+ 24V
5
OUT 2
6
GND
Indicator LED’s
1
+ 24V
2
PWR
3
RUN
4
ALA
5
WRN
6
+ 24V
7
BUZ
Dustbin
sensor
1
+ 24V
2
IN 1
3
GND
4
SHD
Fan Pressure
sensor
1
+ 24V
2
IN 2
3
GND
4
SHD
Analog
output
1
OUT
2
GND
3
SHD
Digital input 1-5
1
+ 24V
2
IN 1
3
+ 24V
4
IN 2
5
+ 24V
6
IN 3
7
+ 24V
8
IN 4
9
+ 24V
10
IN 5
11
COM1
12
GND
Digital input 6-12
1
+ 24V
2
IN 6
3
+ 24V
4
IN 7
5
+ 24V
6
IN 8
7
+ 24V
8
IN 9
9
+ 24V
10
IN 10
11
+ 24V
12
IN 11
13
+ 24V
14
IN 12
15
COM2
16
GND
CAN Slave
1 2
CAN_H
3
CAN_L
4
GND
5
SHD
+ 24V
Power
+ 24V
2
GND
1
1 2
A
3
B
4
GND
5
SHD
RS485 VFD
8
1
NO 1
2
NC 1
3
COM 1
4
5
NO 2
6
NC 2
7
COM 2
Light tower
1
+ 24V
2
PWR
3
RUN
4
ALA
5
WRN
6
+ 24V
7
BUZ
Filter Pressure
sensor
1
+ 24V
2
IN 3
3
GND
4
SHD
CAN HMI
1 2
CAN_H
3
CAN_L
4
GND
5
SHD
+ 24V
8
Rela
y 1
R
ela
y 2
IN 5 External start/stop signal
IN 6 Fire alarm (ShieldControl)
IN 7 Sliding valve feedback 1
IN 8 Sliding valve feedback 2
IN 9 Fan alarm
IN 10 Compressed air switch
IN 11 External alert
IN 12 Dustbin level switch
SCS
:
cleaning v
alv
es (1 or 2)
MDB
: (only f
or ShieldC
on
tr
ol)
- out1
sliding v
alv
es
- out2
c
onpr
essed air r
elease
IN 1 BTN start/stop fan
IN 2 BTN filter cleaning
IN 3 Service mode switch
IN 4 Spare
Wiring colours
+24V
red
CAN_H
white
CAN_L
blue
GND
black
SHD
drain wire (with
shrink tube)
Fig. 4.10 Connection of SlaveBoard
Panel
In case of multiple filter modules
• Proceed with paragraph 4.4.4
In case of one (1) filter module
• Put the termination plug
18
(B) on the CAN OUT connector
on the PC board.
• Make sure that the DIP switches are correctly set.
• Close the lid.
4.4.4 SlaveBoard
SlaveBoard
In case of multiple filter modules, you must make a serial
connection of the cables.
18. Supplied with the Panel
SlaveBoard cable (#1)
19.
Address configuration pos. 1-4: according to number
1
The number of cables supplied is equal to the number of filter
modules, minus 1 (one). Each filter module contains four
screw holes for connection of the tube clamps.
Scope of supply
Cable #2
Cable SlaveBoard
SlaveBoard, including:
- conduit
- conduit connectors M20 + nuts
2x
Tube clamp + screw
- Due to the cable length, you can only make
horizontal and vertical connections. It is
not
possible to make diagonal connections.
- Refer to Fig. IV on page 17 for an example of
the correct connection sequence.
- In case of an installation with one or more
MDB-BM/2 filter modules, you have
one shorter
cable.
- For the position of the CAN IN and CAN OUT
connectors, refer to Fig. III on page 17.
• Remove the lids of all SlaveBoards.
• Remove the cover caps
20
from the sides.
• If necessary, change the position of the blind plug(s).
• Install 2 tube clamps per cable in the screw holes (A) of
each filter module
21
. Fasten them with a screw.
To install the conduit – including cable – between two
SlaveBoard boxes:
• Remove the nuts of the conduit connectors.
• Put the cable ends through the openings of the SlaveBoard
boxes that you want to connect.
• Put the nuts over the cable ends inside the box and fasten
them to the conduit connectors (C).
• Click the conduit in the tube clamps.
• Connect the cable to the CAN OUT
connector of the first
filter module.
• Connect the other end of the cable to the CAN IN connector
of the next filter module.
• Continue the same way to connect all SlaveBoards.
• Put the termination plug
22
(B) on the CAN OUT connector of
the last filter module.
• Put a screw plug in the opening of the last SlaveBoard box
and tighten it with the nut M20
23
.
20. 2 per SlaveBoard
21.
1 tube clamp in case of a filter module MDB-BM/2
22. Supplied with Panel
SlaveBoard cable (#1)
23. Both supplied with Panel
SlaveBoard cable (#1)