0000112607/010420/A ControlGo 

8

Cable #1

A

C

B

(CAN IN)

E (2x)

Fig. 4.9  Connection of SlaveBoard

Fig. 4.10

•  Cut the cable to the necessary length for connection to the 

Panel. 

Indicator LED’s

Valves

Digital input 1-5

CAN Slave

Digital input 6-12

Filter Pressure

sensor

Light tower

Power

Rela
y 1 

    R
ela
y 2

+

-

Cable #1

Indicator LED’s

Valves

Dustbin

sensor

Fan Pressure

sensor

Digital input 1-5

RS485 VFD

CAN Slave

CAN HMI

Digital input 6-12

Filter Pressure

sensor

Analog

output

Light tower

Power

Rela
y 1 

    R
ela
y 2

Ethernet 

(for service only)

USB

(firmware updates)

RS-232

(for service only)

Filter pressure

(internal sensor)

Fan pressure

(internal sensor)

+

-

+

-

Valves

1

+ 24V

2

OUT 1

3

GND

4

+ 24V

5

OUT 2

6

GND

Indicator LED’s

1

+ 24V

2

PWR

3

RUN

4

ALA

5

WRN

6

+ 24V

7

BUZ

Dustbin

sensor

1

+ 24V

2

IN 1

3

GND

4

SHD

Fan Pressure

sensor

1

+ 24V

2

IN 2

3

GND

4

SHD

Analog

output

1

OUT

2

GND

3

SHD

Digital input 1-5

1

+ 24V

2

IN 1

3

+ 24V

4

IN 2

5

+ 24V

6

IN 3

7

+ 24V

8

IN 4

9

+ 24V

10

IN 5

11

COM1

12

GND

Digital input 6-12

1

+ 24V

2

IN 6

3

+ 24V

4

IN 7

5

+ 24V

6

IN 8

7

+ 24V

8

IN 9

9

+ 24V

10

IN 10

11

+ 24V

12

IN 11

13

+ 24V

14

IN 12

15

COM2

16

GND

CAN Slave

1 2

CAN_H

3

CAN_L

4

GND

5

SHD

+ 24V

Power

+ 24V

2

GND

1

1 2

A

3

B

4

GND

5

SHD

RS485 VFD

8

1

NO 1

2

NC 1

3

COM 1

4
5

NO 2

6

NC 2

7

COM 2

Light tower

1

+ 24V

2

PWR

3

RUN

4

ALA

5

WRN

6

+ 24V

7

BUZ

Filter Pressure

sensor

1

+ 24V

2

IN 3

3

GND

4

SHD

CAN HMI

1 2

CAN_H

3

CAN_L

4

GND

5

SHD

+ 24V

8

Rela
y 1 

    R
ela
y 2

IN 5  External start/stop signal

IN 6  Fire alarm (ShieldControl)

IN 7  Sliding valve feedback 1

IN 8  Sliding valve feedback 2

IN 9  Fan alarm

IN 10  Compressed air switch

IN 11  External alert

IN 12  Dustbin level switch

SCS

:

cleaning v

alv

es (1 or 2)

MDB

:  (only f

or ShieldC

on

tr

ol)

  - out1 

  sliding v

alv

es 

  - out2 

  c

onpr

essed air r

elease

IN 1  BTN start/stop fan

IN 2  BTN filter cleaning

IN 3  Service mode switch

IN 4  Spare 

Wiring colours

+24V

red

CAN_H

white

CAN_L

blue

GND

black

SHD

drain wire (with 

shrink tube)

[page 6]

Fig. 4.10 Connection of SlaveBoard 

 Panel

In case of multiple filter modules

•  Proceed with paragraph 4.4.4

In case of one (1) filter module 

Fig. 4.11

•  Put the termination plug

18

 (B) on the CAN OUT connector 

on the PC board. 

Fig. 4.12 + Fig. 4.13

19

•  Make sure that the DIP switches are correctly set.  

•  Close the lid. 

4.4.4  SlaveBoard 

 SlaveBoard

In case of multiple filter modules, you must make a serial 

connection of the cables. 

18.  Supplied with the Panel 

 SlaveBoard cable (#1)

19.

  Address configuration pos. 1-4: according to number 

1

The number of cables supplied is equal to the number of filter 

modules, minus 1 (one). Each filter module contains four 

screw holes for connection of the tube clamps.

Scope of supply

Cable #2

Cable SlaveBoard 

 SlaveBoard, including: 

 

- conduit 

 

- conduit connectors M20 + nuts

2x

Tube clamp + screw

 

- Due to the cable length, you can only make 

horizontal and vertical connections. It is 

not

 

possible to make diagonal connections.

 

- Refer to Fig. IV on page 17 for an example of 

the correct connection sequence.

 

- In case of an installation with one or more 

MDB-BM/2 filter modules, you have 

one shorter 

cable.

 

- For the position of the CAN IN and CAN OUT 

connectors, refer to Fig. III on page 17.

Fig. 4.11

•  Remove the lids of all SlaveBoards. 
•  Remove the cover caps

20

 from the sides.

•  If necessary, change the position of the blind plug(s).
•  Install 2 tube clamps per cable in the screw holes (A) of 

each filter module

21

. Fasten them with a screw.

To install the conduit – including cable – between two 

SlaveBoard boxes:

•  Remove the nuts of the conduit connectors.
•  Put the cable ends through the openings of the SlaveBoard 

boxes that you want to connect.

•  Put the nuts over the cable ends inside the box and fasten 

them to the conduit connectors (C).

•  Click the conduit in the tube clamps.
•  Connect the cable to the CAN OUT

 connector of the first 

filter module.

•  Connect the other end of the cable to the CAN IN connector 

of the next filter module.

•  Continue the same way to connect all SlaveBoards.
•  Put the termination plug

22

 (B) on the CAN OUT connector of 

the last filter module.

•  Put a screw plug in the opening of the last SlaveBoard box 

and tighten it with the nut M20

23

.

20.  2 per SlaveBoard
21.

  1 tube clamp in case of a filter module MDB-BM/2

22.  Supplied with Panel 

 SlaveBoard cable (#1)

23.  Both supplied with Panel 

 SlaveBoard cable (#1)

Содержание CONTROLGO

Страница 1: ...www plymovent com Control panel CONTROLGO Installation and user manual EN...

Страница 2: ...ument and is therefore subject at any time to change or amendment and the right to change or amend is hereby expressly reserved The instructions in this publication only serve as a guideline for insta...

Страница 3: ...ControlGo of Plymovent is an intelligent control panel including the required connection cables This system controls the compressed air valves of the connected filter system MDB or SCS and the connec...

Страница 4: ...rtificates CE 1 6 Ambient conditions 1 6 1 ControlGo Panel Pressure sensors Ambient temperature internal external min nom max 0 C 32 F 20 C 68 F 50 C 122 F 20 C 4 F 20 C 68 F 50 C 122 F Max relative h...

Страница 5: ...n EN ISO 12100 1 is the use for which the technical product is suited as specified by the manufacturer inclusive of his directions in the sales brochure In case of doubt it is the use which can be ded...

Страница 6: ...es approuv es et sch mas lectrique des armoires en question ATTENTION Risque de tension lectrique Il pourrait tre n cessaire d installer un interrupteur principal pour mettre hors tension la machine a...

Страница 7: ...n wire A and the cable jacket B Heat shrink the shrink tube with a heat gun C C A B C B 15 Recommended cable specifications use cables with a max wire diameter 1 5 mm AWG 16 All cables 3 Put the wires...

Страница 8: ...0 IN 10 11 24V 12 IN 11 13 24V 14 IN 12 15 COM2 16 GND Digital input 6 12 1 24V 2 IN 6 3 24V 4 IN 7 5 24V 6 IN 8 7 24V 8 IN 9 9 24V 10 IN 10 11 24V 12 IN 11 13 24V 14 IN 12 15 COM2 16 GND Valves 1 24V...

Страница 9: ...SlaveBoard SlaveBoard including conduit conduit connectors M20 nuts 2x Tube clamp screw Due to the cable length you can only make horizontal and vertical connections It is not possible to make diagon...

Страница 10: ...he correct sequence start with the upper left filter module 1 address from left to right subsequently from top to bottom 24 The red module on the PC board Addressing sequence Address configuration pos...

Страница 11: ...rm signal from an external device27 start stop signal cable 4 alarm signal cable 5 remove the wire bridge from input IN 11 27 E g a welding robot or a timer Indicator LED s Valves Digital input 1 5 CA...

Страница 12: ...ressure sensor Remove the wire bridge from input IN 4 refer to Fig 4 6A Indicator LED s Valves Digital input 1 5 CAN Slave Digital input 6 12 Filter Pressure sensor Light tower Power Relay 1 Relay 2 2...

Страница 13: ...Push the START STOP FAN button ref Fig 6 1F to start the fan Push the button again to stop the fan Filter cleaning system 3 MDB only Push the FILTER CLEANING button ref Fig 6 1G to activate the filter...

Страница 14: ...tem continues to run 32 The system stops running G Black button FILTER CLEANING to activate an additional filter cleaning cycle to suppress the buzzer push and hold for 5 seconds 33 to reset the warni...

Страница 15: ...MODUS MODE DE SERVICE MODO SERVICIO EXTERNAL DEVICE EXTERN APPARAAT EXTERNES GER T DISPOSITIF EXTERNE DISPOSITIVO EXTERNO External device In the ALARM mode the fan system stops immediately 7 MAINTENA...

Страница 16: ...ective Repair or replace the fan motor connection Repair or replace the fan control equipment NO COMPRESSED AIR GEEN PERSLUCHT KEINE DRUCKLUFT ABSENCE D AIR COMPRIM FALTA DE AIRE COMPRIMIDO COMMUNICAT...

Страница 17: ...l rules EN IEC 61131 2 2007 Programmable controllers Part 2 Equipment requirements and tests EN IEC 61000 6 2 2005 Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity for industrial...

Страница 18: ...rolGo 17 ANNEX Fig I Dimensions Panel A C D E F B mm in A 435 17 1 B 400 15 7 C 400 15 7 D 425 16 7 E 225 8 9 F 210 8 3 Fig II SlaveBoards Fig III SlaveBoard PC board CAN OUT CAN IN Fig IV Connection...

Страница 19: ...ILTERSVERSTOPT FILTER GES TTIGT FILTRES OBSTRU S FILTROS OBSTRUIDOS NO COMPRESSED AIR GEEN PERSLUCHT KEINE DRUCKLUFT ABSENCE D AIR COMPRIM FALTA DE AIRE COMPRIMIDO COMMUNICATION ERROR COMMUNICATIEFOUT...

Страница 20: ...ssed air switch 9 Filter pressure sensor PT 2500 H05VV F 3G0 5 10 SCS Slave valve H05VV F 3G0 75 11 Fan control direct online H05VV F 4X0 5 12 Control cable SCS valve compressed air switch H05VV F 5G0...

Страница 21: ...l open B Push and hold the black button Turn the main switch on at the same time Continue to hold the button the white LED shows a heartbeat blinking pattern Learning Mode is starting up C When the gr...

Страница 22: ...5 seconds B Make sure that the number of flashes corresponds with the number of filter cartridges C If NOT and the buzzer sounds no filter cartridges are detected at all Push the black button during 5...

Страница 23: ...FAN SCS 2 SCS 2 ready A B Flowchart SCS 2 Explanatory notes A By default the yellow LED blinks one time with an interval of 5 seconds B Push the green button to change the setting from 1 to 2 filter s...

Страница 24: ...mware update has failed Possible causes failure during the update process corrupt update files on the USB stick you have tried to upload an older firmware version than the existing one you have tried...

Страница 25: ...www plymovent com 0000112607 010420 A ControlGo...

Отзывы: