0000112607/010420/A ControlGo
9
Cable #2
FIRST filter module
LAST filter module
FIRST
LAST
B
A
C
Fig. 4.11 SlaveBoard
SlaveBoard
Address SlaveBoards
To arrange the compressed air valves of the entire filter
system to pulse in the correct sequence, you must configure
the DIP switches of each individual filter module.
The DIP switch module
24
contains 6 DIP switches. Position 5+6
are pre-configured in the factory.
• Make sure that DIP switches position 5+6 are correctly set.
MDB-BM/2
MDB-BM/4
1
2
3
4
Addressing
sequence:
MDB-BM/2 +
MDB-BM/4 +
Configuration of filter module :
Address configuration:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
0000112547/A
pos. 5+6
1
2
3
4
Addressing
sequence:
MDB-BM/2 +
MDB-BM/4 +
Configuration of filter module :
Address configuration:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
0000112547/A
pos. 5+6
Fig. 4.12 DIP switches pos. 5+6
• Set the DIP switches 1 to 4 as indicated. It shows the
address configurations of max. 16 filter modules
(=MDB-64).
ATTENTION
Make sure that you address the filter modules in the
correct sequence:
-
start with the upper left filter module (1)
- address from left to right
- subsequently from top to bottom
24. The red module on the PC board
Addressing sequence
Address configuration pos. 1-4
1
2
3
4
Addressing
sequence:
MDB-BM/2 +
MDB-BM/4 +
Configuration of filter module :
Address configuration:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
0000112547/A
1
2
3
4
Addressing
sequence:
MDB-BM/2 +
MDB-BM/4 +
Configuration of filter module :
Address configuration:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
0000112547/A
Fig. 4.13 Setting of DIP switches pos. 1 to 4
• Close all lids.
The outside of the lid contains a sticker that helps you to
identify each separate filter module.
•
Use a black marker to number the filter modules. Make
sure that the sequence corresponds with the setting of the
DIP switches.
Fig. 4.14
Numbering of the filter modules
4.4.5 Compressed air switch MDB
25
The compressed air switch monitors the availability of
compressed air
26
.
Indicator LED’s
Valves
Digital input 1-5
CAN Slave
Digital input 6-12
Filter Pressure
sensor
Light tower
Power
Rela
y 1
R
ela
y 2
+
-
25. Proceed with paragraph 4.4.6 in case of an SCS
26. The system gives a warning signal when there is no compressed air available